UniBloc Moisture Analyzer

Open the catalog to page 1
MOC63u - 2

MOC63u Trust the MOC63u for Both Speedy and Accurate Measurements Moisture ratio measurements are indispensable for quality control and as checks of raw materials in a variety of industries including food products, chemistry, and pharmaceuticals. The MOC63u electronic moisture analyzer is capable of accurate, quick and easy moisture ratio measurements. Just place the sample in the sample pan and close the cover to start the measurement. This instrument can accommodate virtually any sample, and will contribute to enhanced user productivity. Main Applications Customers in the Food Product...

Open the catalog to page 2
MOC63u - 3

Simple Operating Panel and Excellent Expandability (2) (1) Compatible with the EP-80 printer. Equipped with I/O port. (2) Built-in RS-232C interface is standard. (3) Equipped with USB interface. Importing data to a PC is easy. Sample Printout Sample measurement results output (1) A cross-shaped key layout has been adopted for excellent operability. : MOC63u Model : D209400009 Serial no. : 0000 Instrument ID : 0040 Sample code : Feb. 16, 2011 Date : 16:27 Time : 0 Program no. : Measurement reference Wet basis moisture ratio Measurement conditions: Automatic ending mode Drying temperature...

Open the catalog to page 3
MOC63u - 4

Measurement of Milk • Fiberglass sheets for liquid measurement were used to promote liquid evaporation. • Two measurement conditions were used, timed ending and automatic ending modes. Essentially the same average values were obtained. With samples whose principal component has a relatively high evaporation temperature and also contains moisture, the same results will be obtained regardless of the mode used. Measurement of Milk Measurement conditions: 140"C/TIME 10 min. (Before measurement) 1 g of milk was dripped on to (After measurement) The moisture has evaporated a fiberglass sheet for...

Open the catalog to page 4
MOC63u - 5

•Polished koshihikari rice was used as the sample. The grains were measured as is, without pulverization. • Almost no rice bran remained, so it was assumed that any lost weight would be due solely to moisture evaporation. There were few volatile components aside from moisture, so favorable repeatability was obtained. • The entire sample turned yellow after drying. This was likely due to surface scorching. Measurement of White Rice Measurement conditions: 200 "C/AUTO 0.05 % The drying curve for white rice in automatic ending mode is shown below. Sample Measurement of Corn Starch • Approx. 5...

Open the catalog to page 5
MOC63u - 6

• A sludge cake is created by drying sediments extracted from a sewage treatment plant. It is later incinerated. It is important to measure the moisture ratio, because the incineration energy will be excessive if there is too much moisture. • A sludge cake is a moisture-containing solid, and may also contain fiber. This was placed on the pan, and pulverized to a diameter of about 10 mm or less. Because of the bad odor, taking the time to thoroughly pulverize it was impossible. • The moisture ratio was 81 %, with good repeatability. This is likely because the sample contains essentially no...

Open the catalog to page 6
MOC63u - 7

Note 1: Measurement times, moisture ratios, and CV (%) values are aggregated from three data cycles. Note 2: The CV (%) is the standard deviation divided by the average value, multiplied by 100 to represent it as a percent.

Open the catalog to page 7
MOC63u - 8

(*1) The repeatability (standard deviation) value is from a standard measurement (sample: sodium tartrate dihydrate). This value is not guaranteed for all samples, environments, and measurement conditions. 1 Sample pan 2 Aluminum sheet 3 Sample pan handler 4 In use protection cover 5 Fuse Read instruction manual before using this instrument. • Use this instrument for measurements in which water vaporizes from the sample under heating. • The temperature of the heater installed in this instrument becomes higher than the set heating temperature for the sample. • Any sample that is explosive,...

Open the catalog to page 8

All Shimadzu catalogs and technical brochures

  1. UV-1900i

    4 Pages

  2. LCMS-9030

    12 Pages

  3. LCMS-8050

    20 Pages

  4. LCMS-8045

    12 Pages

  5. XRD-6100

    32 Pages

  6. EDX-LE

    16 Pages

  7. PDA-8000

    16 Pages

  8. AA-6200

    12 Pages

  9. UV-3600i Plus

    20 Pages

  10. SPM-9700HT

    27 Pages

  11. SALD-2300

    20 Pages

  12. IG-1000 Plus

    16 Pages

  13. MB140

    4 Pages

  14. MOC63u

    2 Pages

  15. MOC-120H

    4 Pages

  16. UW/UX Series

    4 Pages

  17. New products

    1 Pages

  18. BL series

    2 Pages

  19. BW-K/BX-K

    2 Pages

  20. MOC-120H

    4 Pages

Archived catalogs

  1. MOC63U Flyer

    2 Pages

  2. UW/UX Series

    4 Pages

  3. SALD-7101

    16 Pages

  4. MOC63U

    6 Pages