UniBloc Moisture Analyzer
Open the catalog to page 1|\/|^^^^CO| i High-performance Moisture Analyzer IVI^^^^wOU applicable for a wide application range. Easy operation -Automatic starting mode- Easy-to-operate software Automatic starting mode saves measurement time. Backlight display jminated display provides comfortable display visibility Compact design class. Width is only 202 (mm). Long lifetime halogen heater Halogen heater promises Data management -wmdowsDirect- The measurement conditions and data can standard. Send balance data to Excel or other Windows applications.
Open the catalog to page 2Choose the right measuring mode for your application. Ending modes • Automatic ending mode Automatically ends measurement when moisture loss over the previous 30 seconds becomes smaller than specified percentage. • Timed ending mode Automatically ends measurement when the specified amount of time has elapsed. Alternate drying modes • Rapid drying mode First dries with the highest temperature for the specified period, then shifts to the specified temperature shortening measurement time. • Slow drying mode Gently heats samples that might solidify at the surface or samples that reduce under high...
Open the catalog to page 3Measurement data With WindowsDirect Measurement data of soft flour Measurement data of milk Soft flour Measurement data of resin pellet Standard sample Measurement data of the sodium tartrate dihydrate Resin pellet
Open the catalog to page 4Excellent performance for a wide variety of applications in multiple industries.
Open the catalog to page 5Accessories list Standard accessories ln-use protection cover for display (5 pieces) Aluminum sheet Fiberglass sheet 10 Halogen heater for replacement Read Instruction manual before using this Instrument. • Use this Instrument for measurements In which water vaporizes from the sample under heating. • The temperature of the heater Installed In this Instrument becomes higher than the set heating temperature for the • Any sample that Is explosive, Inflammable or may cause hazardous reaction under heating must not be measured with this Instrument. SHIMADZU CORPORATION. International Marketing Division...
Open the catalog to page 612 Pages
20 Pages
12 Pages
32 Pages
16 Pages
16 Pages
12 Pages
20 Pages
27 Pages
20 Pages
16 Pages
8 Pages
16 Pages
6 Pages
1 Page
1 Page
4 Pages
8 Pages
4 Pages
8 Pages
24 Pages
20 Pages
8 Pages
8 Pages
2 Pages
2 Pages
140 Pages
8 Pages
4 Pages
4 Pages
48 Pages
2 Pages
4 Pages
5 Pages
4 Pages
2 Pages
4 Pages
16 Pages