video corpo

PDA-8000
16Pages

{{requestButtons}}

Catalog excerpts

PDA-8000 - 1

Optical Emission Spectrometer

Open the catalog to page 1
PDA-8000 - 3

A New Design of Spectrometer with Higher Stability High accuracy and stability measurement achieved by the latest optical design A Novel Excitation Unit Equipped with real-time energy monitoring Sophisticated Software Total support for control and management of the instrument with an intuitive interface A New Design of Spectrometer with Higher Stability A Novel Excitation Unit Shimadzu's Unique Pulse Distribution Analysis Photometry Intuitive Software PDA-R Automatic Analysis System Specifications, Installation and Optional Accessories

Open the catalog to page 3
PDA-8000 - 4

A New Design of Spectrometer with Higher Stability High accuracy and stability measurement achieved by the latest optical design

Open the catalog to page 4
PDA-8000 - 5

More Precise Analysis Achieved with a High-Resolution Spectrometer Using a Paschen-Runge Spectrometer with the focal length of 1000mm, and a diffraction grating suitable for each of ferrous or non-ferrous application, PDA-8000 offers high-resolution measurements with less spectral interference over a wide wavelength range. Stable and Proven Vacuum Spectrometer Oxygen inside the spectrometer needs to be removed because it absorbs spectral lines in the vacuum-ultraviolet wavelength range, and some important elements in material analysis have spectral lines in this range, including Phosphorus,...

Open the catalog to page 5
PDA-8000 - 6

A Novel Excitation Unit Equipped with real-time energy monitoring

Open the catalog to page 6
PDA-8000 - 7

Constant Monitoring of the Discharge Status A Realtime Energy Monitoring* function is provided to monitor the discharge energy consumed between the counter electrode and the sample. The discharge energy is accurately set and controlled, and discharge defects due to the surface condition of the sample can be instantly detected from the discharge energy. The accuracy is improved by eliminating samples with defects from the measurement. *Patent pending Discharge defect Real-time energy monitoring Supporting Diverse Metal Materials Many metal materials can be analyzed over a wide range of...

Open the catalog to page 7
PDA-8000 - 8

Shimadzu's Unique Pulse Distribution Analysis Photometry Pulse Height Distribution Analysis (PDA) Method Provided as Standard The spectral intensity signal from the detector obtained for each pulse discharge is fed in for each analysis element, and converted into a frequency distribution. By performing statistical processing appropriate for each analysis element, the measurement accuracy can be improved and information on the element form can be extracted. Discharge crater Light emitting section Spectral intensity The spectral intensity of internal standard elements is monitored, and only...

Open the catalog to page 8
PDA-8000 - 9

Frequency Distribution Processing Unlike conventional emission spectrometry that integrates the spectral intensity, Shimadzu's unique PDA method performs frequency distribution processing on the spectral intensity of each discharge pulse. For example, when a discharge spot is applied to inclusions such as manganese sulfide (MnS) or aluminum oxide (Al2O3), the spectral intensity of that element is increased. When the spectral intensity of elements that readily form inclusions is converted into a frequency distribution, the distribution form is not symmetrical. For these elements that readily...

Open the catalog to page 9
PDA-8000 - 10

Intuitive Software PDA-R Total support for control and management of the instrument with an intuitive interface Fusion of Hardware and Software From control and diagnosis to maintenance—reliable instrument management with software integrated with the hardware. The operating time of each part is controlled by each unit, so there is no problem when replacing PCs. Of course, they can be easily checked with the software. The software supports complete maintenance management for stable use of the instrument. • Lens cleaning procedure • Pump oil replacement • Electrode replacement • Entrance slit...

Open the catalog to page 10
PDA-8000 - 11

The Pursuit of Greater Ease-of-Use, Based on Reliability A sophisticated, operator-friendly design has been developed utilizing our cumulative emission spectrometry experience. Plots can be set for each sample, with more intuitive and easy-to-understand operation Working curve setting screen Working curve plot setting screen Before correction Matrix element correction Wide variety of display patterns for analysis data Plots can be distinguished for each sample type to visually check the correction status of the working curves. Analysis data control diagrams Display pattern setting

Open the catalog to page 11
PDA-8000 - 12

Electrode-Cleaning Unit Automatic sample retainer mechanism To enhance long-term stability, the optional electrode-cleaning unit keeps the counter electrode clean by brushing away adhering sample deposits. Used to reduce the effect of the heat energy generated by high-energy discharge. A separate cooling water circulator is necessary. Cooling Water Circulator (P/N 044-01809-10) Handles samples between 3 mm and 12 mm in diameter. more more more more more more more (1) Emission table (2) Insulating washer (3) Mylar * When ordering multiple parts at the same time or adding to the existing...

Open the catalog to page 12
PDA-8000 - 13

Options for Sample Preparation Sampling Mold (P/N 210-00005) Pour molten metal from a cupola, electric furnace, or low-frequency induction furnace into the sampling mold. Molten metal Mushroom type Sampling mold Surface plate FS-3N (Special) Belt Grinder with Dust Collector (50 Hz: P/N 085-50206-15) (60 Hz: P/N 085-50206-16) Size: W441 × D680 × H883 mm Weight: Approx. 97 kg Power Supply: 3-phase 200 V 1150 W Disk type Belt grinder Size: W770 × D420 × H350 mm Weight: Approx. 75 kg Power Supply: Single phase 100 V 300 W Order the following 1) and 2) with the bench lathe. 1)Tip holder...

Open the catalog to page 13
PDA-8000 - 14

Automatic Analysis System The optimal system can be configured by combining with sample preparation units to suit the customers' needs. A 6-axis multi-articulated robot is used for sample handling to perform automatic analysis rapidly, efficiently, and safely. The instrument performs automatic calibration to always maintain the optimal condition. Example of process analysis sample ID input screen Set the sample ID in accordance with guidance. The processing status of each analysis sample and the instrument status are displayed. The PC type and the touch panel type are available. Start...

Open the catalog to page 14

All Shimadzu catalogs and technical brochures

  1. UV-1900i

    4 Pages

  2. LCMS-9030

    12 Pages

  3. LCMS-8050

    20 Pages

  4. LCMS-8045

    12 Pages

  5. XRD-6100

    32 Pages

  6. EDX-LE

    16 Pages

  7. AA-6200

    12 Pages

  8. UV-3600i Plus

    20 Pages

  9. SPM-9700HT

    27 Pages

  10. SALD-2300

    20 Pages

  11. IG-1000 Plus

    16 Pages

  12. MB140

    4 Pages

  13. MOC63u

    2 Pages

  14. MOC-120H

    4 Pages

  15. MOC63u

    8 Pages

  16. UW/UX Series

    4 Pages

  17. New products

    1 Pages

  18. BL series

    2 Pages

  19. BW-K/BX-K

    2 Pages

  20. MOC-120H

    4 Pages

Archived catalogs

  1. MOC63U Flyer

    2 Pages

  2. UW/UX Series

    4 Pages

  3. SALD-7101

    16 Pages

  4. MOC63U

    6 Pages