video corpo

SALD-2300

SALD-2300
1 / 20 PagesView full catalog

SALD-2300

Product catalog summary
Introduction
The SALD-2300 is a Laser Diffraction Particle Size Analyzer designed for research applications across various industries, including pharmaceuticals, cosmetics, and electronics. It complies with ISO 13320 and JIS Z 8825-1 standards.
Specifications
The analyzer supports particle concentrations from 0.1ppm to 20% and measures sizes from 17nm to 2500µm. It allows continuous measurements at 1-second intervals and is compatible with previous models like SALD-2001, SALD-2101, and SALD-2201.
Measurement Capabilities
Using laser diffraction, the SALD-2300 calculates particle size distribution by analyzing scattered light intensity patterns. It can measure both wet and dry samples, with specific systems for different sample types.
Features and Functions
The system includes functions for evaluating particle size distribution changes, a self-diagnostic function, operation log, and the ability to display raw data alongside results for comprehensive analysis.
Applications
The SALD-2300 is versatile, suitable for industries like pharmaceuticals, cosmetics, foods, and electronics. It can measure high-concentration samples without dilution and supports various measurement methods.
Performance and Validation
Performance validation is possible using standard particles specified in JIS Z 8900-1. The system offers high resolution, reliability, and reproducibility, with an OSAF frame for stability.
Conclusion
The SALD-2300 is a robust tool for precise particle size analysis, offering high efficiency and throughput. Its adaptability and compliance with international standards make it suitable for a wide range of applications.
Automatic Refractive Index Calculation
The WingSALD II software includes an automatic refractive index calculation function using the LDR method, ensuring accurate measurements without trial and error.
Standard Operating Procedures (SOPs)
The system supports SOP creation, saving, and sharing, ensuring consistent measurement conditions across operators and locations.
Real-Time Monitoring and Analysis
The analyzer allows real-time tracking of sample changes, crucial for evaluating processes like dissolution, with statistical processing and 3D graph functions.
System Components
The system includes components like a condensing lens, flow cell, laser light source, and various sensors. It supports both wet and dry measurement methods.
Measurement Techniques
Wet measurement uses various dispersion media, while dry measurement uses a cyclone injection mechanism, effective for magnetized or easily agglomerated particles.
Key Features
The system allows high-concentration sample measurement without dilution, reducing the risk of altering particle size distribution. It offers multiple nozzle options for optimal dispersion.
Data Analysis Functions
The system supports real-time display, diagnostics, recalculation of particle size distribution, and statistical data processing, handling up to 200 data sets.
Software and Hardware Requirements
The software is compatible with Windows 10 and requires specific hardware configurations, including a Core i5 or i7 CPU and USB ports.
Importance of Particle Size Distribution
Particle size distribution affects product quality in various industries, influencing properties like efficacy, texture, and stability.
Laser Diffraction Method
The SALD-2300 uses laser diffraction to measure particle size distribution, determining sizes from scattered light intensity patterns.
See more

Catalog excerpts

SALD-2300-1

Laser Diffraction Particle Size Analyzer

 Open the catalog to page 1
SALD-2300-2

Applicable to a Wide Range of Applications Using Optional Unit s and Application Sof t ware Packages Provides Accurate Evaluation of the Change in Par ticle Size Dis tribution, Conforming to ISO13320 Laser Diffraction Particle Size Analyzer Laser Diffraction Particle Size Analysis? Particle size distribution can be calculated using the light intensity distribution pattern of scattered light which is generated from sample particles when laser irradiates them. This is the main particle size analysis method because it has excellent properties such as a wide measurement range, a short measurement...

 Open the catalog to page 2
SALD-2300-3

Wide applicability High resolution High concentration High repeatability High reliability High sensitivity High throughput High efficiency High analysis capability Powerful new functions have been added to accurately evaluate the change in particle size distribution. Particle size distribution can have a major effect on the characteristics desired for a given application or objective, or on the performance and quality of a final product. A particle size analyzer with the ability to precisely measure particle size distribution is an essential tool in today’s laboratory. The SALD-2300 is that tool....

 Open the catalog to page 3
SALD-2300-4

Wide applicability ■ Using the SALD-MS23 sampler, the measurement range is 17nm to 2500µm for wet measurement. For example, PSL particles with a median diameter of 50nm and stainless balls with a diameter of 2mm can be measured by a single analyzer. PSL particles 50nm median diameter Normalized Particle Amount (Diff) Normalized Particle Amount (Cum) Normalized Particle Amount (Diff) Normalized Particle Amount (Cum) Stainless balls of 2mm diameter ■ The system configuration can be optimized to address various uses, purposes, measurement objects, environments and conditions. Sampler SALD-MS23 Measurement...

 Open the catalog to page 4
SALD-2300-5

High resolution Accurately detects particle size distribution with five peaks Scattered light from coarse particles is concentrated at low angles near the optical axis and fluctuates vigorously within a tiny angle, but scattered light from microparticles fluctuates slowly up to large angles away from the center. Whereas the intensity of scattered light from coarse particles is extremely high, the intensity of scattered light from microparticles is very low. The SALD-2300 achieves high resolution over a wide range of particle sizes by utilizing the relationship between particle size and scattered...

 Open the catalog to page 5
SALD-2300-6

High efficiency / High reliability Automatic refractive index calculation function eliminates the mistake or trouble of selecting refractive indices. Automatic Refractive Index Calculation Function Is Available. Selecting a refractive index was an unavoidable part of using the laser diffraction method, in which a published value was generally entered. However, such values were not necessarily appropriate, considering the effects of particle composition and shape. Therefore, tedious trial and error processes were used to select refractive indices. WingSALD II solves such problems by being the...

 Open the catalog to page 6
SALD-2300-7

High efficiency / High reliability Assist function decreases operational error to ensure more accurate measurement. Measurement Assistant Function Allows Preparing SOPs to Ensure Measurements Are Always Performed Using the Same Conditions and Procedures. Anyone can conduct high-quality measurements anywhere at any time. With the SALD-MS23, SALD-BC23, and SALD-DS5S, automatic measurement by PC control can be conducted according to a specified SOP. The operator's work consists of sample preprocessing and inputting only. Creating, saving, and sharing measurement conditions and procedures, including...

 Open the catalog to page 7
SALD-2300-8

By enabling measurement under wide particle concentration conditions (0.1ppm to 20%), changes in particle size distribution depending on particle concentration can be evaluated. High sensitivity / High concentration Previously, the particle concentration of a sample had to be adjusted to meet the optimum conditions of analyzers by dilution or concentration using a centrifuge. In these cases, changes in particle size distribution, such as agglomerations or dispersions, could not be considered. Dispersions and agglomeration can be caused by dilutions. In some cases, dilutions can accelerate dispersions,...

 Open the catalog to page 8
SALD-2300-9

High speed Changes in particle size distribution can be monitored in real-time. Continuous measurement function at 1-second intervals can record these processes for additional analysis. Particle size distribution data and light intensity distribution data can be displayed in real-time. This means that sample changes over time or shifts in the dispersion status can be monitored in real-time. Since both the light intensity distribution data, which is the raw data, and particle size data can be monitored simultaneously, they can be compared to keep track of any changes in the status of samples....

 Open the catalog to page 9
SALD-2300-10

High efficiency Processes multiple sets of data more efficiently Multiple sets of data can be stored as a group, which enables easier organization, re-displaying, and reanalysis of data. Data can be loaded as a group and displayed or analyzed at the same time, rather than having to load each set separately. High analysis capability Measurement data from multiple facets –Extensive assortment of data analysis applications included standard The following data analysis applications are included standard. ■ Evaluation of Scattering Angle Graphs the components of scattered light intensity at each angle....

 Open the catalog to page 10
SALD-2300-11

System Structure Wide range of system configurations can be designed by adding optional units. Measurement Unit SALD-2300 The batch cell and the high-concentration sample measurement system can be set in the measurement unit. Small-Volume Measurement System (SALD-2300 and SALD-BC23) High-Concentration Sample Measurement System (SALD-2300 and SALD-HC23S) Very Small-Volume Measurement System (SALD-2300 and SALD-HC23S and “Glass Slides with Indentation”) SALD-DS5S (Sampling unit and dispersion device) 1210mm or more Wet/Dry Measurement Full System (SALD-2300 and SALD-MS23 and SALD-DS5S) SALD-DS5S...

 Open the catalog to page 11

All Shimadzu catalogs and technical brochures

  1. LCMS-9030

    12  Pages

  2. LCMS-8050

    20  Pages

  3. LCMS-8045

    12  Pages

  4. XRD-6100

    32  Pages

  5. EDX-LE

    16  Pages

  6. PDA-8000

    16  Pages

  7. AA-6200

    12  Pages

  8. UV-3600i Plus

    20  Pages

  9. SPM-9700HT

    27  Pages

  10. IG-1000 Plus

    16  Pages

  11. New products

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.