Catalog excerpts
X-ray Diffractometer
Open the catalog to page 1Ease of Use and Abundant Functions Herald a New Era of Analysis The Windows-supported application software ushers this compact, multi-functional, general-purpose X-ray Diffractometer into the networking era of analysis. X-Ray Diffractometer In addition to its basic ease of use and abundant functions, the XRD-6100 boasts an integrated design featuring a vertical goniometer and data processing software supporting the Windows user interface. The XRD-6100 offers solutions encompassing wide-ranging analysis requirements, from routine qualitative and quantitative analysis to state change...
Open the catalog to page 2A General-Purpose X-ray Diffractometer to Address Your Various Analytical Needs Fe a tu res Hi g h -Prec i s i o n a nd Re lia ble Built -in Ve r t ica l G oniom e t e r The goniometer mounted on the XRD-6100 is compact and simple. All the components in the X-ray optical system are precisely assembled and adjusted at the factory and have been designed to ensure that accuracy is maintained. Thus, there is absolutely no need for users to make any adjustments in the future. Wi n d o ws 10 Em ploy e d a s S of t w a re P la t f or m The main unit control and data processing software support the...
Open the catalog to page 3Applications of X-ray Diffractometry F e rro u s Meta ls Steel Qualitative analysis of steel sheet, measurement of residual austenite and residual stress, analysis of friction and wear test samples, measurement of iron oxide films and nitride layers, evaluation of plating and texture. Cast Iron Qualitative analysis of precipitates and additives in cast iron, etc. Surface-Treated Steel Evaluation of characteristics of surface-treated areas, quality control, residual stress measurement. N o n - F e rro u s Meta ls Copper and Zinc Qualitative analysis of alloys, orientation measurements of...
Open the catalog to page 4Pharmac eutic als and M edic al Treat m en t Pharmaceuticals Qualitative analysis of pharmaceutical raw materials and identification of impurities. Crystal polymorphism analysis and crystallinity measurements, quality control during pharmaceutical manufacture using crystallite size measurement, final product quality check, crystal polymorphism analysis related to patents. Dental Materials Qualitative analysis of dental materials such as apatite, etc. Electrical and Electronic Materials Electrical Components Qualitative analysis of corrosion and adhering matter on electrical contacts. Stress...
Open the catalog to page 5Polycapillary Optical System Principle of the Polycapillary Optical System Schematic Diagram of the Polycapillary Optical System The fine glass capillaries in the order of several microns are arranged in a solid as guides to multiple X-rays. The X-rays pass along each capillary while repeating total internal reflection and exit from the opposite end of the polycapillary system. The capillaries are curved so that repeated total internal reflection is allowed, and the X-rays from the point X-ray source exit the unit as a parallel beam with a large solid angle. Output divergence angle 0.22°...
Open the catalog to page 6Qualitative and Quantitative Analysis of Asbestos and Free Silicic Acids The content of asbestos in construction materials is measured using phase dispersion microscopes and X-ray diffractometers. After pulverizing the sample acquired from the site in a pulverizer, a phase dispersion microscope and X-ray diffractometer are used respectively to qualitatively analyze the sample. If the sample is determined to contain asbestos at this stage, then it is quantitatively analyzed using the X-ray diffractometer. In actual practice, asbestos analysis (JIS A 1481-3) requires sensitivity sufficient to...
Open the catalog to page 7Cons truc tion The XRD-6100 analyzes crystalline states under normal atmospheric conditions. Furthermore, this method is non-destructive. X-rays hit a sample loaded in the center of the goniometer and are diffracted by the sample. The changes in the diffracted X-ray intensities are measured, recorded and plotted against the rotation angles of the sample. The result is referred to as the X-ray diffraction pattern of the sample. Computer analysis of the peak positions and intensities associated with this pattern enables qualitative analysis, lattice constant determination and/or stress...
Open the catalog to page 8X-ray Tubes Highly Stable X-ray Generator The XRD-6100 will accept various types of X-ray tubes, including the normal focus (NF) 2kW type and broad focus (BF) 2.7kW type, which are standard accessories, as well as the optional long fine focus (LFF) 2.2kW type. By attaching the optional counter monochromator, all types of samples, including Fe samples, can be analyzed using the standard Cu X-ray tube. Shimadzu's extensive experience in producing high-performance X-ray generators has enabled the production of a highly stable X-ray generator, with tube voltage and tube current both stable to...
Open the catalog to page 9Providing a Complete Analysis System Analysis System Standard Software X-ray generator control Optical path adjustment X-ray ON/OFF, tube voltage/current setting Goniometer adjustment Detector adjustment Single scan, multi-scan File maintenance ASCII data conversion ASCII data to XRD-6100 data conversion XD-D1 data to XRD-6100 data conversion Basic data processing Graphic display Smoothing, background elimination, Kα1-Kα2 separation, peak search, system error correction, internal/external standard correction, operations between data Vertical display, horizontal display Overlay display (3D)...
Open the catalog to page 10Automatic Measurement, Easy Operation Measurement Display Sample measurement conditions can be set easily. The scheduling and the progress condition of the measurement can be confirmed in one view by the analysis & spooler. Measurement Screen Multitasking for Enhanced Analysis Efficiency Basic Data Processing The multitasking capability provided with the Windows operating environment allows measurement and data processing to be conducted simultaneously, enhancing the efficiency of analysis operations. Basic Data Processing Screen
Open the catalog to page 11Comfortable Data Processing Environment Graphic Display Data can be freely zoomed with a click of the mouse, so profile comparison of thin film data or heating measurement data can be easily accomplished using a combined 2-dimensional or 3-dimensional display. The software also features a variety of other useful graphic functions, such as intensity Log conversion display and hidden-line processing on the 3-dimensional display. Each type of data can be output to a color printer, so differences between samples can be recognized at a glance. 3-Dimensional Screen of Thin Film Sample...
Open the catalog to page 12All Shimadzu catalogs and technical brochures
-
RADspeed Pro EDGE
5 Pages
-
UV-1900i
4 Pages
-
LCMS-9030
12 Pages
-
LCMS-8050
20 Pages
-
LCMS-8045
12 Pages
-
EDX-LE
16 Pages
-
PDA-8000
16 Pages
-
AA-6200
12 Pages
-
UV-3600i Plus
20 Pages
-
SPM-9700HT
27 Pages
-
SALD-2300
20 Pages
-
IG-1000 Plus
16 Pages
-
DSC-60 Plus Series
8 Pages
-
TOC process analysis
16 Pages
-
MB140
4 Pages
-
GC Column Guidebook
48 Pages
-
ATX/ATY Series
6 Pages
-
MOC63u
2 Pages
-
MOC-120H
4 Pages
-
MOC63u
8 Pages
-
UW/UX Series
4 Pages
-
Application Handbook Clinical
140 Pages
-
New products 1
1 Pages
-
New products
1 Pages
-
BL series
2 Pages
-
BW-K/BX-K
2 Pages
-
TX/TXB/TXC Series
8 Pages
-
HMV- 2 brochure
8 Pages
-
AutographA G - XSeries
20 Pages
-
Solutions Brochure
24 Pages
-
PSSM - 8 System
8 Pages
-
MOC-120H
4 Pages
-
AUW-D / AUW / AUX / AUY
8 Pages
Archived catalogs
-
MOC63U Flyer
2 Pages
-
ATX/ATY Series_2013
4 Pages
-
UW/UX Series
4 Pages
-
SALD-7101
16 Pages
-
MOC63U
6 Pages