NTA Implant Company Group is a leader in dental implants, offering Screw-type and Press-fit implants. They are certified by FDA, CE, ISO 9001:2015, ISO 13485:2016, and ISO 10002:2018, ensuring high standards in safety and reliability.

Product Specifications
The implants feature Single Pitch Macro Thread, Helix Cutting Edge, and Corkscrew Thread for stability and stress distribution. The platform design supports platform switching, enhancing vascularization and reducing healing time. A conical connection with an internal hex index ensures a bacterial seal.

Implant Design
Root form implants facilitate placement and stress distribution. The apical design improves stability in low-quality bone, while the body design merges straight and tapered implant benefits.

Surgical and Prosthetic Components
The NTA system includes healing, temporary, and solid abutments. The surgical kit minimizes surgery time and trauma. Prosthetic flow diagrams guide the Octa and Multi systems.

Surface Treatment
The SLA surface, achieved through sand-blasting and acid-etching, enhances tissue interaction and reduces bacterial risk.

Conclusion
NTA Implant provides stable, user-friendly, and quality-assured dental implant solutions, catering to various indications with innovative features.

Overview
The document details specifications and product codes for dental abutments and components, including screw types, diameters, heights, and fastening torques.

Specifications
Abutment types include regular, narrow, hex, and non-hex, each with specific product codes and dimensions. Fastening torques are 20Ncm for narrow and 30Ncm for regular abutments.

Procedures and Recommendations
Hex drivers (1.2mm) are recommended for fastening, with optional protective caps for abutments. Correct torque settings are crucial for installation and stability.

Product Codes and Dimensions
Tables provide product codes for abutment configurations, detailing fixture diameters, gingival heights, and angles for angled abutments.

Digital Technology and Innovation
Digital solutions like intraoral scanners and cloud storage enhance dental restoration, reducing operation time and improving communication.

Clinical Applications
Digital technology benefits dental restoration, implant, and orthodontics through real-time data analysis and reduced preparation time.

Additional Features
Features such as anti-fog functions, depth of field, and color scanning improve procedure accuracy and efficiency.
See more

Catalog excerpts

nta implant-1

You can access all information by scanning the QR code below with your Smartphone / Tablet

 Open the catalog to page 1
nta implant-2

“To improve is to change; to be perfect is to change often” Winston Churchi

 Open the catalog to page 2
nta implant-3

Nta Implant Company Group Our company is engaged in providing solutions in implant dentistry by offering highest quality of dental implants. Development, manufacturing process, marketing, publicity, and trademark rights of all the products are legal and belong to our company. The products are being developed using state of the art technologies under the light of the up-to-date scientific data in the field of implantology. We manufacture “Screw-type” and “Press-fit” implants with their accessories under the brands of Nta Implant, Nta Shorter Implant, Nta Shorter Plus Implant and Hybrid Implant....

 Open the catalog to page 3
nta implant-4

DIAMETER LENGHT Conical Connection With Hex Conical connection provides bacterial seal and prevents microleackage issues at implant-abutment interface. Internal hex index ensures proper and easy seating of the abutment. Platform Design Single Pitch Macro Thread Synchronized thread Preferred design for SLA surface High fixture strength Open Thread Prevents bone necrosis Reduces stress concentration Smaller platform compared to many designs allows platform switching. Corkscrew Thread Superior self-threading Ensures implant path Easy path change High primary stability Even stress distribution Decrease...

 Open the catalog to page 4
nta implant-5

INTERNAL SUB-MERGED SYSTEM The SLA surface is produced by a large grit sand-blasting process with corundum particles that leads to a macro roughness on the titanium surface. This is followed by a strong acid-etching bath with a HCl at elevated temperature for several minutes. This produces the fine 2-4 μm micro pits superimposed on the rough-blasted surface. The surface is not micro porous and therefore provides no enclosed volumes to reduce vulnerability to bacteria. The chemical composition of the SLA structure was found to be titanium oxide (TiO2) using X-ray photoelectron spectroscopy. This...

 Open the catalog to page 5
nta implant-6

Abutment Screw ( Set screw ) Abutment Screw ( Set screw ) Angled Milling Cemented Multi Angled Solid Abutment Cemented Abutment Solid Temporary Locater Soft Tissue Titanium Temporary Bone Forming NTA PACKING SYSTEM New Ampoule User’s Guide Transfer Type Impression Coping Remove the back of blister (sterility is not guaranteed if the seal is broken). Keep the small cover upward. Closing Screw Gold metalic color Ø 3.4 narrow Remove the cover by gently rotating and pulling. Insert the driver into the fixture and make sure that the driver is fully seated. Remove the cover screw from the small chamber...

 Open the catalog to page 6
nta implant-7

NTA PROSTHETIC FLOW DIAGRAMS FOR OCTA SYSTEM NTA PROSTHETIC FLOW DIAGRAMS FOR MULTI ( ALL ON FOUR ) SYSTEM Octa Screw Multi Screw Multi Low Temporary Cylinder Octa Plastic Cylinder Multi Open Tray Imp. Coping Multi Cemented Cylinder Multi Low Transfer Imp. Coping Octa Protect Cap Multi Outer Driver Closing Screw Octa Impression Coping Octa Abutment Multi Low Plastic Cylinder Octa Lab Fixture Analog Octa Outer Driver Multi Abutment Multi Angled Abutment Healing Abutment 1.2 Screw Driver Closing Screw Healing Abutment

 Open the catalog to page 7
nta implant-8

NTA PROSTHETIC FLOW DIAGRAMS FOR NTA SYSTEM OVERDENTURE RETAINED RESTORATION : N-LOC Internal Sub-merged System Metal Housing N-Loc Analog Ball Outer Driver Closing Screw N-Loc Impression Coping N-Loc Driver Healing Abutment

 Open the catalog to page 8
nta implant-9

The implant body is taper thread and this provide spreading stress at the top of the implant. The depth of the threads at the apex part is the highest and its reduce by degrees inside the platform. The design of the implant enhance blood supply and minimalise the empty place in cortical bone to decrease bone formation period. Straight Body Implant and abutment excellent connection is waranted. 11° degree morse tapered connection is reducing stress on the fixture and decrease bone loss. Open Thread In the course of implant placement, open thread gives opportunity to place fixture deep without...

 Open the catalog to page 9
nta implant-10

For Guided Bone Regeneration Immediate Placement Initial Fixation GBR Sinus graft Implant stability Vertical augmentation Immediate implant placement Fixture Soft Tissue Healing Abutment NTA Soft Tissue Healing Abutment Product Code HA STHA 553 M HA STHA 905 T HA STHA 907 T HA STHA 909 T Bone Forming Healing Abutment is used for protecting bone graft from tongue and saliva. BF Healing abutment covers bone graft with BF’s specific design. Bone Forming Healing Abutment D : Diameter T : Thickness C : Cuff Product Code HA BFHA 105 HA BFHA 205 HA BFHA 335 HA BFHA 106 HA BFHA 206 HA BF

 Open the catalog to page 10
nta implant-11

NTA® HEALING ABUTMENT Internal Sub-merged System Esthetic Abutments conical connection; Prefabricated titanium abutments available in straight and angled ; and varying collar heights. ! Abutment Esthetic aHex Driver: 1.2 mm. aFastening Torque:5-8Ncm. Product Code

 Open the catalog to page 11
nta implant-12

NTA® TEMPORARY ABUTMENT NTSA 45545 NTSA 45555 NTSA 45565 NTSA 45517 Product Code Height narrow Product Code NTA® SOLID NTA® TEMPORARY ABUTMENT - TITANIUM Product Code Product Code NTA® SOLID ABUTMENT a An abutment and a set screw, used a Hex driver: 1.2mm. a Fastening Torque: 20Ncm (Narrow) - 30Ncm (Regular) a Protect cap: Optional.

 Open the catalog to page 12
nta implant-13

NTA® CEMENTED ABUTMENT Diameter Product Code Product Code NTCA 55635 H NTCA 55645 H NTCA 55665 H prosthesis and multiunit fixed partial restorations. a Hex driver: 1.2mm. a Fastening Torque: 20Ncm (Narrow) - 30Ncm (Regular) a Protect cap: Optional. 5 a Abutment for both single unit NTA® CEMENTED ABUTMENT NTCA 40527 H NTCA 40537 H NTCA 40547 H a Abutment for both single unit prosthesis and multiunit fixed partial restorations. a Hex driver: 1.2mm. a Fastening Torque: 20Ncm (Narrow) - 30Ncm (Regular) a Protect cap: Optional. NTCA 65727 H NTCA 65737 H NTCA 65747 H

 Open the catalog to page 13
nta implant-14

NTA® CEMENTED ABUTMENT Diameter Product Code NTAA 55225 MH NTAA 55325 MH NTAA 55425 MH NTAA 50107 SH prosthesis and multiunit fixed partial restorations. a Hex driver: 1.2mm. a Fastening Torque: 20Ncm (Narrow) - 30Ncm (Regular) a Protect cap: Optional. 5 a Abutment for both single unit Product Code NTA® ANGLED ABUTMENT 4 1 a Fastening Torque: 20Ncm (Narrow) - 30Ncm (Regular)

 Open the catalog to page 14