RANGE OF AUDIOMETER PRODUCTS “screening”, basic diagnosis, clinical diagnosis • Calculation of hearing loss and diagnosis • Internal database > 1000 tests • Suprathreshold tests • High frequency • Musical frequencies • Automatic masking • Connectivity with other management systems • Customizable
Open the catalog to page 1CONFIGURATION ACCORDING TO MODEL Frequency modulation and amplitude modulation Two channels Pure tone threshold audiometry by air conduction Pure tone threshold audiometry by bone conduction Pure tone threshold audiometry by free field Pure tone suprathreshold audiometry (SISIGRAM) Pure tone suprathreshold audiometry (Fowler-ABLB, Tone Decay, Weber, Lüscher, etc.) Speech audiometry High frequency audiometry Masking with narrow band noise Masking with white noise Masking with speech noise Synchronized masking Intermediate frequencies: 125, 750, 1500 Hz Musical frequencies Selection of exploration...
Open the catalog to page 2The SIBELSOUND 400, is a revolutionary two-channel audiometer. The entire system is controlled by Digital Signal Processor (DSP) for reliable, quick and easy audiometric exploration of hearing thresholds and screening tests, such as suprathreshold pure tone tests. The SIBELSOUND 400 audiometer was developed by SIBEL, S.A.U.'s RDI department in collaboration with the Surgery Department (Ear, Nose and Throat and Audiology) of the University of Barcelona and well-known specialists in the field, in accordance with standard criteria of both national institutions such as the UNE and international institutions...
Open the catalog to page 3SIBELSOUND 400 · audiometer Reset To return to the previous menu, cancel an action, delete data entries or place the counters at zero. Right ear attenuator Activates or deactivates a signal, depending on the "direct/inverted" working mode. Right channel signal Silencer or key which, when activated, sends or blocks the signal transmitted to the patient, depending on whether the working mode is direct or inverted. Hz. Decreases and/or increases the frequency of the pure tone signal applied to the patient. Save Saves a test to the database. SISIGRAM Generates the manual increases in the SISIGRAM...
Open the catalog to page 4SIBELMED W50 is sophisticate software for viewing, storage, transmission, analysis and introduction of audiometric tests in a Microsoft Windows ® environment with the following options: • Management of various patient databases • Download of audiometric test data from SIBELSOUND 400 and AC50 audiometers • Manual audiometric test data input performed with other audiometers • Display of different types of audiometric tests (COUNCIL, IMSS MEXICO, ELI, SAL, KLOCKHOFF, MOH, others...) • Choice of various types of diagnosis parameters • Test graphics • Comparison of tests from the same patient • Customizable...
Open the catalog to page 5Bone conduction Free field MASKING NOISE Free field HIGH FREQUENCY Air conduction Minimum levels All options HIGH FREQUENCY Level increases STANDARD Reference tone Frequency precision Level precision Functional specifications: See tables of models and frequencies Transducers: TDH39 - DD450 - B71W (depending on the model) Screen: LCD alphanumeric backlighted 2 X 16 Protection: Time restricted high frequency signals to protect both patient and unit Self-check: Automatically checks the status of the audiometer Unit test: Allows the user or technician to check the condition of certain functions or...