1. Catalogs
  2. SIEVE France
  3. IM range isolator - IM2111 EC

IM range isolator - IM2111 EC

IM range isolator - IM2111 EC

IM range isolator - IM2111 EC

Product catalog summary
IM Range Isolator Overview
Use: The isolator is designed for handling toxic and/or sterile products, specifically for applications such as sterile medicines, eye drops, chemotherapy, monoclonal antibodies, and clinical trials.
Composition: The system includes one technical block with two entry airlocks, a double isolator with one workstation each, and one technical block with two exit airlocks. Each of the two independent isolators is equipped with one workstation, one sterilizable airlock entry, and one sterilizable airlock exit.
Layout and Dimensions: The workstations are laid out with dimensions of 2400 mm (94.49 inches) in length, 1410 mm (55.51 inches) in width, and 1900 mm (74.80 inches) in height.
Electrical Specifications: The isolator operates on a 230 V single-phase supply with a 30 mA residual current device for protection (20A curve D and 16A curve C). The average power consumption is 400 W, with a maximum of 3200 W.
Pneumatic Characteristics: The system requires a minimum pressure of 4 bars and consumes less than 1 liter per minute of clean and dry air.
Air Flow Characteristics: Air extraction is conducted via airlock at 50 m3/hour during rinsing and via isolator at 100 m3/hour.
Other Characteristics: The weight of the technical inlet/outlet unit is 322 kg (709.89 lb), the isolator weighs 368 kg (811.9 lb), and the output technical unit weighs 210 kg (462.97 lb), with a total weight of 900 kg (1984.16 lb). The load on the ground is 266 kg/m² (586.43 lb), and the sound pressure during production is less than 65 dB(A).
Requirements: The system requires a power supply with a minimum of two cables (3G2.5mm²), a computer network with four network cables (4 pairs, including 1 VPN and 1 spare per workstation), a pneumatic supply with a female connector (1/4 or 1/8), and air extraction from the isolator with two PVC pressure pipes ( 63 mm) and one PVC pressure pipe ( 63 mm) for the extraction of sterilizing agent vapors.
See more

Catalog excerpts

IM range isolator - IM2111 EC-1

Isolator designed for handling toxic and/or sterile products ♦ 1 technical block 2 entry airlocks ♦ 1 double isolator equipped with 1 workstation each ♦ 1 technical block 2 exit airlocks IM range isolator IM2111 ec 2 independent isolators equipped with: > 1 airlock entry sterilizable each > 1 airlock exit sterilizable each

 Open the catalog to page 1
IM range isolator - IM2111 EC-2

Electrical specifications:_ Pneumatic characteristics: _ 4 bars minimum < 1 liter / minute Clean and dry Other characteristics:

 Open the catalog to page 2

All SIEVE France catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.