1. Catalogs
  2. Silbermann Technologies
  3. AMBULANCE OXYGEN DELIVERY SYSTEM - 2 sources
video corpo

AMBULANCE OXYGEN DELIVERY SYSTEM - 2 sources

AMBULANCE OXYGEN DELIVERY SYSTEM  - 2 sources

AMBULANCE OXYGEN DELIVERY SYSTEM - 2 sources

Product catalog summary
Overview
The Ambulance Oxygen Delivery System by SILBERMANN Technologies Ltd. is designed to provide a continuous flow of oxygen to patients during transport. It manages two oxygen cylinders, ensuring a seamless switch between them to maintain a reliable supply.

System Features
  • Automatic changeover between cylinders for uninterrupted oxygen flow.
  • Touchscreen alarm panel that monitors gas pressure and alerts staff in case of pressure drops.
  • Various medical gas outlet types available, including Sil-Ohio, ENV 737-6, and others.
  • Visual and audio alarms for low pressure and cylinder changeover.
  • 10.1” full HD LCD touchscreen displaying gas pressure and status of each source.
  • Advanced communication options including TCP/IP Modbus and optional web remote view.
  • Optional SMS alerts and 4G modem for real-time monitoring.

Specifications
  • Power requirements: 12V DC from ambulance electrical supply.
  • Flow rate capacity up to 100 liters per minute.
  • Input pressure up to 200 bar, output pressure regulated to 3.5-4 bar.

Standards and Quality
  • Complies with ISO 10524, EN-1789, NFPA 1917 standards.
  • Quality Management System certified to ISO 9001-2015 and ISO 13485-2016.

Ordering Information
  • Specify type and number of medical gas outlets required.
  • Indicate required cylinder connection; default is G 3/4.
  • Additional equipment like flowmeters and suction units must be ordered separately.

Diagram and Components
  • Includes medical oxygen outlets, high and low-pressure transducers, flexible gas hoses, and signal cables.
  • Optional GPS data for ambulance location tracking.
See more

Catalog excerpts

AMBULANCE OXYGEN DELIVERY SYSTEM  - 2 sources-1

Emergency Medical Services <S Silbermann Medical Gas Systems Since 1950 The Ambulance Oxygen Delivery system is a vital component of emergency medical services, enabling a continuous flow of oxygen to patients in need during transport to medical facilities. The System manages 2 sources and provides continuous supply and smooth automatic switchover between the sources. A touchscreen alarm panel monitors the gas pressure in each cylinder and shows/alerts the medical staff in case of a pressure drop. Oxygen outlets enable easy and safe connection to the system, and ensure a constant and reliable oxygen flow for the patient. ■ Automatic changeover between cylinders to ensure continuous and reliable oxygen flow. ■ Medical Gas outlets type: Sil-Ohio, ENV 737-6, Puritan Bennett type, DIN, British standard, DISS*. ■ Control Alarm panel monitor highlights: ■ Presenting actual time left for treatment (in minutes) based on preset flow rate parameters. ■ Visual & audio alarm signals in case of low pressure in change between cylinders. ■ 10.1” full HD LCD touchscreen - graphicly and digitally displaying the cylinder gas pressure and output pressure, alerting in case of a pressure drop. ■ Graphically & digitally display of the actual status of each source - “In use” or “Stand by”. ■ Periodical maintenance alert ■ Advanced Communication: TCP/ IP Modbus. ■ Leak detection from cylinders. * The quantity and types of oxygen gas outlets are available based on customer requirements. ■ Gas expiration date alert - an alert for the medical gas cylinder expiration date. ■ Log History File- Event logging, recording all alarms and panel activities. ■ Customizable text & language. ■ A color trend arc showing the gas pressure status on the main line and at each cylinder. ■ Automatic adjustment of screen brightness ■ Web remote view on the Internet: online view accessible via a web browser. This website allows authorized users to remotely access and view the data in real-time - optional ■ Additional data: GPS data showing the current location of each ambulance by its number - optional ■ SMS alert when oxygen pressure reduces to a pre-set level - optional ■ 4G modem installed - optional Applicable Standards: Silbermann’s Quality Management System: <553' Medical Gas Systems Since 1950 Address: #5 Harakevet st. POB 4605, Petah-Tikva, 4900715, ISRAEL Tel: +972-3-9309186 | Fax: +972-3-9315721 E-Mail: [email protected], www.silbermnn.com

 Open the catalog to page 1
AMBULANCE OXYGEN DELIVERY SYSTEM  - 2 sources-2

Emergency Medical Services Ambulance Oxygen Delivery System for 2 Cylinders Diagram Oxygen Cylinder Oxygen Cylinder (supplied by others) (supplied by others) Specifications: ■ Gas sensors/Pressure 4-20 mA transmitters. ■ Output pressure: 3.5-4 bar (Regulated pressure) ■ Flow rate capacity of up to 100 liters per minute. ■ Voltage: 12V DC supplied from Ambulance Electrical Supply Power. ■ 5A Slow Blow fuse 5x20mm. ■ Specify the type and number of medical gas outlets required. ■ Indicate the required cylinder connection, otherwise G 3/4 shall be supplied. Medical Gas Systems Since 1950 Address:...

 Open the catalog to page 2

All Silbermann Technologies catalogs and technical brochures

  1. Humidifier

    1  Page

  2. Air Motor

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.