Adam, A.J. & Defibrillation Trainer
12Pages

{{requestButtons}}

Catalog excerpts

Adam, A.J. & Defibrillation Trainer - 1

Adam , A.J. & Defibrillation Trainer CPR Training Manikins Instructions For Use,Care and Maintenance Latex Free

Open the catalog to page 1
Adam, A.J. & Defibrillation Trainer - 2

The purpose of this manual is to familiarize the user with the function, care and maintenance of the Simulaids Adam CPR™ and AJ CPR™ training manikins. It is not meant to provide instruction in Cardiopulmonary Resuscitation (CPR) or other emergency life support procedures. Please read it thoroughly before attempting to use your manikin. All Simulaids manikins are designed and manufactured to exacting standards and will provide years of effective and trouble free use when the simple steps of care and maintenance are regualarly performed after each training session. FEATURES Both Adult &...

Open the catalog to page 2
Adam, A.J. & Defibrillation Trainer - 3

INFLATION When the head is in a neutral position, the ball in the AIRWAY CUT-OFF VALVE is in a forward position, preventing air from entering the lungs. This replicates an obstructed airway of an unconscious person in need of emergency ventilation. (Fig. #2) When proper head tilt and chin lift is applied, the ball will roll rearward and open the valve. This allows the air to pass through the corrugated tube in the neck and the nonrebreathing valve. Air then enters the lung and causes a visible rise in the chest. (Fig. #3) EXHALATION When inflation ceases the non-rebreathing valve closes and...

Open the catalog to page 3
Adam, A.J. & Defibrillation Trainer - 4

DISASSEMBLY 1. After removing shirt and carotid pulse bulb assembly, remove CHEST SKIN from torso and remove/discard the disposable lung. (Fig. #4)

Open the catalog to page 4
Adam, A.J. & Defibrillation Trainer - 5

2. Remove EXHAUST TUBE from port at base of torso. (Fig. #5) 3. Stand torso upright and remove mouth/nose piece from face. Remove HEAD by unsnapping the two tab strips and lift from torso with valve and tubes attached. (Fig. #6)

Open the catalog to page 5
Adam, A.J. & Defibrillation Trainer - 6

4. Remove AIRWAY CUTOFF VALVE from inside the head by unthreading nut inside oropharyngeal area. (Fig. #7) Set aside for cleaning and disinfecting. NOTE: AIRWAY CUTOFF VALVE, MOUTH/NOSE pieces and LOWER AIRWAY may be cleaned and disinfected by following the procedure described in the manual. (Lungs cannot be reused.) CLEANING & DISINFECTION The only components of Adam CPR™ and AJ CPR™ that require scrupulous disinfection is the AIRWAY CUT-OFF VALVE and the MOUTH/NOSE pieces. The LOWER AIRWAY tubing and valve are designed to be disposed of at the end of the training class. However, they may...

Open the catalog to page 6
Adam, A.J. & Defibrillation Trainer - 7

No. 100 DEFIBRILLATION TRAINER Do not open electronic boxes. There are no user serviceable electronic parts. Lay manikin down, face up with neck collar when storing. Before using this unit read all directions carefully. Manikin Connections: Manual Defibrillatior: Install proper adapters in the defibrillation sites on the overlay skin. Connect the monitoring leads from the monitor to the lead positions on the skin. Connect the four color coded leads from the defibrillation skin to the Arrhythmia Simulator Box. Turn on the Arrhythmia Simulator Box to generate waveforms. Deliver shock to...

Open the catalog to page 7
Adam, A.J. & Defibrillation Trainer - 8

ILLUSTRATION: Adam CPR™ WITH ELECTRONICS Catalog #2300 AJ CPR™ WITH ELECTRONICS Catalog #2400 POWER SUPPLY / ELECTRONIC MODEL The manikin console box contains 4 “AA” batteries (included). To replace batteries, slide open the panel from the underside of console box. Remove old batteries and replace with 4 new “AA” batteries in proper polarity (+ or -) direction. Slide the panel back into place. If the lights fail to flash, either the batteries are dead or the leads have become disconnected. Check to make certain that they are in the correct position, contact is being made, and tubing...

Open the catalog to page 8
Adam, A.J. & Defibrillation Trainer - 9

CARRYING BAG WITH KNEELING PADS The carrying bags for your Adam CPR™ and AJ CPR™ are designed so that when completely opened and placed on the floor with the manikin in the middle (see illustration), they become their own “Training/Practice Stations” NOTE: (If the student will place his/her knee on the nylon bag while performing Abdominal Thrusts, it will keep the bag and the manikin from “walking” on th

Open the catalog to page 9
Adam, A.J. & Defibrillation Trainer - 10

RETURN GOODS POLICY Should it be necessary to return an item for any reason, contact our Customer Service Department to obtain a RETURN AUTHORIZATION NUMBER. Merchandise cannot be accepted without prior return authorization. Please refer to your invoice number when phoning in your request for returning merchandise. If needed, a shipping carton and packing instructions will be sent to you to facilitate return

Open the catalog to page 10
Adam, A.J. & Defibrillation Trainer - 11

WARRANTY Simulaids warrants this product to be free from any defect in materials and/or workmanship for a period of three years from the date of purchase, as evidenced by the date of invoice when the product was shipped to the end user. This warranty expressly does not cover abuse, accidental or purposeful damage, or any form of modification to the product. Simulaids reserves the right to either repair or replace affected parts or the entire unit, at their sole discretion, after investigating and reviewing the actual product and the damage. In most instances, a digital photo of the product...

Open the catalog to page 11
Adam, A.J. & Defibrillation Trainer - 12

PO Box 1289 - 16 Simulaids Avenue Saugerties New York 1277 Toll Free (800) 431-4310 Fax (845) 679-8996 www.simulaids.com info@simulaids.com

Open the catalog to page 12

All Simulaids catalogs and technical brochures

  1. 100-1640

    4 Pages

  2. 150-1800

    4 Pages

  3. Alex

    2 Pages

  4. SMART MOM

    2 Pages

  5. SMART STAT