Contact us in various ways www.sinovision-tech.com/en Add : No.8 building, Kangsheng Industrial Park, No.11 Kangding Street, BDA. Beijing, China Tel: 0086(10)87927112 Fax: 0086(10)87927113 E-mail: [email protected] Contents ot the brochure and the parameters indicated thereby are for reference only and shall not serve as legal offers or commitments. SinoVision reserves the rights to revise the contents, design and options in this brochure without separate notification. / AlphaCT 868^ 256-slice smart 3D central target CT
Open the catalog to page 182 cm large boreSmart 3D central target imaging platform ■ Short geometry design enables large bore imaging architecture • Provides sufficient space for smart 3D central target scans ■ Patented technology supports precise diagnosis and treatment
Open the catalog to page 2S,NO#VlS'ON /On Smart central target platform* ■ Al target scanning Smart integration platform ■ Multi-organ joint scanning ■ Multi-mode integrated scanning Smart operation platform Al smart workflow Al smart post-processing solutions
Open the catalog to page 3Focusing on the target, caring all the more Heart rate range: 62-101 bpm, average: 80 bpm; Collimation: 80mm (spiral scan mode); Scan condition: lOOkVp, 718mAs; Rotation speed: 0.235s*; Scan time: 2.3s
Open the catalog to page 4Smart centra target scanning The target was moved to the ISO by moving the table Blurred edge and less details Clear edge and more details Smart central target platform* ■ Large-bore platform empowers smart central target imaging ■ End-to-end smart central target imaging: from scan to reconstruction ■ Precise 4K reconstruction * for higher resolution and more details Smart central target imaging for specific targets from scanning to reconstruction, delivering more diagnostic confidence 'Means optional
Open the catalog to page 5Smart integration platform ■ China’s only CT manufacturer, with a full-process detector production line, ■ The detector possesses a concentric circle arrangement and “just right' thermal ■ Realizes high signal conversion rate, high sampling rate and high resolution *Means optional
Open the catalog to page 6Multi-organ smart integration ■ Multi-protocol switching supports one-stop, multi-organ scanning ■ Multi-mode integration enables efficient and accurate diagnosis
Open the catalog to page 7Smart Al workflow * Al intelligent positioning Al intelligent reconstruction Al intelligent quality control • Intelligently recognizes body parts • One-click isocenter positioning ■ Automatically defines scan range • Optimizes scanning parameters • Deep learning-based reconstruction ■ Precise 4K reconstruction ■ Intelligent dose alerts ■ Image quality traceability Smart positioning Smart scanning Smart reconstruction Smart quality control ‘Means optional
Open the catalog to page 835mAs original image 35mAs image with V-Clarity Radiation dose for lung scans has been reduced by 75%. Note: Authoritative institutions release diagnostic reference levels for radiation dose in adult chest CT examinations. Trained and validated with millions of high and low dose images Optimized scanning conditions to reduce radiation dose Applicable to multiple body parts, not limited to head, chest or abdomen
Open the catalog to page 9Liver Analysis Cardiovasology Electrophysiologic Left Atrial Appendage Occlusion Others* Advanced Energy Spectrum Analysis Means optional