Electrosurgery
20Pages

{{requestButtons}}

Catalog excerpts

Electrosurgery - 1

DYONICS™ RF-S WHIRLWIND 90° Probe • owerful high-flow suction aids P in rapid tissue removal • Provides unobstructed image • ndicated for multiple procedures I DYONICS EFLEX™ Radiofrequency Probes • nable access to multiple zones E in the hip joint • robes can deflect up to 100° P • ultiple configurations M fa

Open the catalog to page 1
Electrosurgery - 2

DYONICS™ RF Arthroscopy System DYONICS RF System DYONICS RF System Smith & Nephew is proud to present a variety of RF options to meet the specialized needs of today’s arthroscopist. The DYONICS RF Radiofrequency System is designed for arthroscopic surgeons who need to rapidly resect and sculpt soft tissue and coagulate bleeding vessels. Patented bipolar technology emphasizes a high degree of control, while maximizing speed and efficiency of tissue removal. Reference # DYONICS RF System System includes: DYONICS RF generator, foot pedal and power cord Foot pedal Accessory Kit includes IFU and...

Open the catalog to page 2
Electrosurgery - 3

DYONICS™ RF Arthroscopy System DYONICS RF System Probe Indications High-performance DYONICS RF probes are designed to deliver rapid resection and precision sculpting of soft tissue. Large surface areas ensure quick tissue removal and cutting, while the patented bipolar technology delivers precisely focused energy to the targeted tissue. Probes are available in a variety of angle and electrode configurations, ideal for shoulder and knee procedures. NON-SUC TION PROBES DY O 722 NICS 02 139 RF-S WH DY IRL ON WI 722 ICS ND 02 RF 90 138 -S °P DY rob NA DY e MO ON 722 ICS 90 °P 02 RF rob 140 -S e...

Open the catalog to page 3
Electrosurgery - 4

DYONICS™ RF Arthroscopy System DYONICS RF System Bipolar Probes Suction Probes These powerful RF suction probes are equipped with a grated suction design that helps trap large debris before potentially causing a blockage. Reference # 72202139 DYONICS RF-S WHIRLWIND 90° Probe, 3.75 mm shaft diameter, 5.5 mm minimum cannula size 72202138 DYONICS RF-S DYNAMO 90° Probe, 3.5 mm shaft diameter, 5.5 mm minimum cannula size 72202140 DYONICS RF-S CROSS 50° Probe, 3.0 mm shaft diameter, 5.5 mm minimum cannula size Non-suction Probes Reference # 72202142 DYONICS RF BROADNOSE 90° Probe, 4.5 mm shaft...

Open the catalog to page 4
Electrosurgery - 5

DYONICS™ RF Arthroscopy System DYONICS RF System Probe Indications – Canada Only Part Numbers High-performance DYONICS RF probes are designed to deliver rapid resection and precision sculpting of soft tissue. Large surface areas ensure quick tissue removal and cutting, while the patented bipolar technology delivers precisely focused energy to the targeted tissue. Probes are available in a variety of angle and electrode configurations, ideal for shoulder and knee procedures. NON-SUC TION PROBES DY O 722 NICS 03 178 RF-S WH DY IRL ON WI 722 ICS ND 03 RF 90 177 -S °P DY rob NA DY e MO ON 722...

Open the catalog to page 5
Electrosurgery - 6

DYONICS™ RF Arthroscopy System DYONICS RF System Bipolar Probes – Canada Only Part Numbers Reference # DYONICS RF System System includes DYONICS RF generator, foot pedal and power cord Foot Pedal Accessory Kit (includes IFU and US power cord) Suction Probes These powerful RF suction probes are equipped with a grated suction design that helps trap large debris before potentially causing a blockage. Description 72203178 DYONICS RF-S WHIRLWIND 90° Probe, 3.75 mm shaft diameter, 5.5 mm minimum cannula size 72203177 DYONICS RF-S DYNAMO 90° Probe, 3.5 mm shaft diameter, 5.5 mm minimum cannula...

Open the catalog to page 6
Electrosurgery - 7

VULCAN™ RF Arthroscopy System VULCAN RF Arthroscopy System The Smith & Nephew VULCAN Arthroscopy System is designed to help improve procedure efficiency and outcome with a complete line of RF products for knee, shoulder, hip and extremity procedures. Flexible Monopolar, bipolar, temperature control and impedance monitoring capabilities aid in optimizing energy delivery to produce the desired tissue effect. Simple All Smith & Nephew RF probes are available with integrated cables which increases staff efficiency by eliminating cable sterilization and storage requirements. Convenient Autoprobe...

Open the catalog to page 7
Electrosurgery - 8

VULCAN™ RF Arthroscopy System VULCAN RF System Probe Indications The Smith & Nephew VULCAN Arthroscopy System includes the most versatile line of RF probes in the industry. Please refer to the following pages for more detail on each of these products. SAPHYRE™, ABLATOR™, SCULPTOR™* DYONICS™ GLIDER LIGAMENT CHISEL™* DYONICS ELECTROBLADE™ Resector Shoulder Subacromial decompression Capsular release Capsulorrhaphy Synovectomy Knee Meniscectomy ACL/PCL debridement Chondroplasty Medial plication Lateral release Hip Acetabular labrum resection Synovectomy Loose body excision Tendon resection and...

Open the catalog to page 8
Electrosurgery - 9

SAPHYRE0 Biopolar Ablation Probes SAPHYRE Ablation Probes SAPHYRE Ablation Probes deliver powerful, consistent RF energy for vigorous soft tissue ablation and hemostasis. The jewel-cut electrodes deliver focused energy to target tissue with reduced current output requirements, generating less heat than competitive ablation probes. In addition, the SAPHYRE Bipolar Ablation Probe Coolback Shaft reduces the risk of secondary tissue heating at the return electrode site. Reference # Description Shaft Color 7209686 SAPHYRE Ablation Probe, 90° Pewter 7209685 SAPHYRE Ablation Probe, 60° Pewter...

Open the catalog to page 9
Electrosurgery - 10

ABLATOR0 and SCULPTOR0 Monopolar Ablation Probes ABLATOR Monopolar Ablation Probes The ABLATOR monopolar probes provide a wide scope of probe styles for arthroscopic applications in the shoulder, knee and small joint. Features such as the power pocket electrode high-flow extractor lumen on suction probes help optimize tissue ablation, coagulation and visualization of the surgical site. Reference # Description 7209659 ABLATOR Ablation Probe, 90° Black 7209654 ABLATOR-S Ablation Probe, 90° with suction Black 7209657 ABLATOR Ablation Probe, 60° Black 7209653 ABLATOR-S Ablation Probe, 60° with...

Open the catalog to page 10
Electrosurgery - 11

VULCAN™ RF Arthroscopy System DYONICS™ GLIDER™ Monopolar Articular Cartilage Probe Designed exclusively for treatment of chondromalacia, indicated specifically for chondroplasty. The DYONICS GLIDER monopolar probe debrides and smooths diseased cartilage along the contoured surfaces of the joint while limiting the depth of chondrocyte death to 150 microns or less.† Articular Cartilage Probe The GLIDER probe is an early-intervention tool for treatment of articular cartilage disease. Through controlled application of RF energy on Grade II and III chondromalacia, the GLIDER probe is designed to...

Open the catalog to page 11

All Smith & Nephew catalogs and technical brochures

  1. polarstem

    8 Pages

  2. anthem

    4 Pages

  3. BST-CarGel ®

    20 Pages

  4. Knee

    73 Pages

  5. HIP