Product Description: The Ear Lavage Catheter is a single lumen open end polyurethane catheter designed with four distal side holes and a proximal female Luer connector. It is intended for veterinary use to flush or aspirate ear wax and debris from the ear canal.
Specifications: The catheter is latex-free and sterilized using ethylene oxide. It is available in models CELC700, CELC850, and CELC1200.
Instructions for Use: Before use, inspect the packaging for sterility and any damage. If damaged, discard the product. The procedure involves sedating or anesthetizing the patient, restraining them in lateral recumbency with the affected ear exposed, and using the catheter with a sterile syringe to flush the ear according to standard hospital protocol. After flushing, the ear canal should be dried.
Warnings: Improper use of the device may damage the ear canal. Failure to immobilize the patient properly during the procedure can result in serious injury or death. Follow local regulations for the disposal of sharps and biohazardous waste. The catheter is for single patient, single application use only and should not be reused.
Contact Information: Manufactured by Smiths Medical PM, Inc., located at N7W22025 Johnson Drive, Waukesha, Wisconsin 53186. For inquiries, contact via phone at 1-262-513-8500 or toll-free at 1-888-745-6562 (U.S.A. only).
Sterilized using ethylene oxide Latex Free Do not reuse. Single patient, single application use. For use by or on the order of a licensed veterinarian. Description The Ear Lavage Catheter is a single lumen open end polyurethane catheter with four distal side holes and a proximal female Luer connector. See individual package label for product specifications. Function The Ear Lavage Catheter is used to flush or aspirate ear wax and debris from the ear canal. Instructions for Use 1. Inspect packaging for sterility. Remove product from package and visually inspect for any damage. WARNING! Discard if product or packaging is damaged. 2. Sedate or anesthetize patient. 3. Restrain patient in lateral recumbency with affected ear exposed. 4. Using catheter and sterile syringe, flush ear in accordance with standard hospital protocol. 5. Dry ear canal. Warning! Improper use of this device may result in damage to the ear canal. WARNING! Failure to properly immobilize patient during the procedure may result in serious injury and/or death. WARNING! Follow local governing ordinances regarding disposal of sharps and biohazardous wastes. Smiths Medical PM, Inc. N7W22025 Johnson Drive Waukesha, Wisconsin 53186 Phone: 1-262-513-8500 Toll-Free: 1-888-745-6562 (U.S.A. only) Fax: 1-262-513-9069 SurgiVet and the Smiths design mark are trademarks of the Smiths Medical family of companies. The symbol ® indicates the trademark is registered in the U.S. Patent and Trademark Office and certain other countries. ©2009 Smiths Medical Family of companies. All rights reserved.