video corpo

SMP-100ML

SMP-100ML
1 / 23 PagesView full catalog

SMP-100ML

Product catalog summary
About SMP Canada: SMP Canada specializes in medical technology, focusing on innovation and excellence. The company prioritizes safety, efficiency, and technological advancement, adhering to global healthcare standards such as NFPA, HTM, CSA, CE, FDA, IEC, UL, and ISO 13485.
General Remarks: The SMP-100ML hospital bed is CE-certified, designed to meet safety and operational requirements. The manual provides essential information for safe use and should be accessible to caregivers and patients.
Performance Characteristics:
  • Removable headboard and footboard for easy access.
  • Manual crank system for backrest adjustment.
  • Retractable aluminum side rails for safety.
  • IV pole with four hooks, installable in all corners.
  • Single wheel castor brakes for easy use.
  • Adjustable back and foot sections for comfort.
  • 5-inch castors for maneuverability.
  • Lightweight side bumpers for protection.
Technical Data: The bed supports a safe working load of 280 kg and a backrest angle of 0-80°.
Warranty and Liability: SMP Canada covers errors within warranty terms but excludes other damage claims. Technical changes may occur.
Safety Regulations: The bed must be used as intended, following safety regulations. Only qualified individuals should operate it. Warnings include avoiding exposure of body parts during crank operation and returning the bed to its lowest position after use.
Operational Safety Checks: Regular checks are essential, with tests recommended before first use and throughout its service life.
Specifications and Intended Use: Designed for hospitals, clinics, and nursing institutions, the bed is not for children under 12, untrained patients, or sloping surfaces over 10°. It should not be moved by pulling on the mattress or with brakes applied.
Safety Precautions:
  • Castor Brakes: Apply brakes when stationary.
  • Movement Adjustment: Ensure no limbs or objects are between the frame and chassis.
  • Side Rails: Operate only by trained caregivers, ensuring they are fully raised and locked or fully lowered.
First-Time Use and Functional Testing: Read the manual and conduct a functional test before first use. Repeat tests for new patients, after storage, cleaning, or annually.
Cleaning and Disinfection: Use non-corrosive agents with a pH of 6-8. Avoid solvents and follow guidelines for water hardness and chemical concentrations.
Maintenance: Minimal maintenance is required, with regular inspections for worn parts or loose screws. Repairs should be conducted by authorized personnel.
Operation Functions:
  • Backrest Adjustment: Use the crank handle.
  • Castor Brakes: Use the lever on the castors.
  • Headboard and Footboard Installation: Align and secure with bolts.
  • Side Rails: Raise or lower by engaging the latch.
Environmental Conditions: For transport and storage, maintain temperatures between -40°C and +70°C, and for use, between 10°C and 30°C. Use in dry rooms and move only on firm surfaces.
See more

Catalog excerpts

SMP-100ML-1

Solutions Start Here... Solutions Start Here www.smpcanada.com 10 Sims Crescent, Richmond Hill Ontario, L4B-1K9 Canada Tel: (905) 764-7767 Fax: 1-866-627-9798 [email protected] USER & MAINTENANCE MANUAL www.smpcanada.com | [email protected] | Tel: 1.905.764.7SMP (1.905.764.7767) | Fax: 1.866.627.9798 10 Sims Crescent, Richmond Hill Ontario, L4B 1K

 Open the catalog to page 1
SMP-100ML-2

USER MANUAL MANUAL BED SMP 100ML About Us We are a company that draws on innovation and excellence to provide solutions that enhance the ability for caregivers to effectively fulfill their duties. Our goal is to build a high-performing medical technology company that gives healthcare providers the tools they need to achieve better outcomes. We are committed to helping our customers deliver safer, more efficient, technologically advanced equipment to the market place. Caregivers throughout the world look to us for solutions because we strive for excellence and adhere to their suggestions for improvement....

 Open the catalog to page 2
SMP-100ML-3

USER MANUAL MANUAL BED SMP 100ML 1 Crank Manual Hospital Bed - User & Maintenance Manual

 Open the catalog to page 3
SMP-100ML-4

USER MANUAL MANUAL BED SMP 100ML General Remarks We congratulate you on your choice of an SMP-100ML hospital bed and would like to thank you for your confidence in our product. You have purchased a SMP-100ML Hospital Bed developed and manufactured in accordance with the current state of technical knowledge. SMP Canada’s manual hospital bed fully meets all safety and operational requirements. They are tested in accordance with international standards and carry the CE seal. This confirms that they fulfill the safety requirements relating to medical products. This user manual is intended to give...

 Open the catalog to page 4
SMP-100ML-5

USER MANUAL MANUAL BED SMP 100ML

 Open the catalog to page 5
SMP-100ML-6

USER MANUAL MANUAL BED SMP 100ML

 Open the catalog to page 6
SMP-100ML-7

USER MANUAL MANUAL BED SMP 100ML 1.1) Removeable Headboard and Footboard for easier access to the patient SMP’s ergonomic design allows the care givers to have access to the patient’s head or feet by instantly removing the headboard and footboard. See section 10.5 for details. 1.2) Single manual crank system SMP-100ML bed allows you to adjust the backrest of the bed via it’s single crank located at the footend of the bed. See section 9, and 10.1for more details. 1.3) Side rails The SMP-100ML is equipped with retractable aluminum side rails which can be used as added safety measure to limit the...

 Open the catalog to page 7
SMP-100ML-8

USER MANUAL MANUAL BED SMP 100ML pushing the bed. Our castors have passed the load bearing test of the European council directive 1002/95/EC & 1005/618/EC. 1.8) Side bumpers In emergency situations, when you are pushing the bed from patient room to surgical room the last thought on your mind is to protect the bed from scrapes and scratches. That is why we have specially designed light weight bumpers and installed them on all four corners of the bed.

 Open the catalog to page 8
SMP-100ML-9

USER MANUALMANUAL BED SMP 100ML2.) Technical Data: No.

 Open the catalog to page 9
SMP-100ML-10

* Product withstands storage/transportation in relative humidity range of 10 to 95% * Product withstands storage/transportation in relative humidity range of 10% to 3.) Warranty and liability We accept liability for possible errors and omissions within the terms of warranty laid down in the main contract. Claims for damages - from whatever legal ground they may be held to derive - are expressly excluded. We reserve the right to make technical changes to the hospital beds described in this user’s manual in accordance with technical developments. We accept no liability whatsoever for damage and/or...

 Open the catalog to page 10
SMP-100ML-11

USER MANUAL MANUAL BED SMP 100ML WARNING! – Increased safety measures are necessary when the bed is being used: • By a child under 12 years of age. • By a person with reduced mental faculties. • For psychiatric purposes. WARNING! – In order to avoid falls, always return the bed to lowest position after each use of the adjustment functions. Make sure that: a) The bed is in lowest position before getting into or out of it, and b) The brakes are applied. WARNING! – Safety frames only mark the limits of the bed. Other appropriate measures must be used to restrain patients. WARNING! • Only use original...

 Open the catalog to page 11
SMP-100ML-12

USER MANUAL MANUAL BED SMP 100ML 4.5) Side Rails - Danger of entrapment In the case of patients whose, physical or mental state may be felt to call for the use of side rails to protect them from falling out of bed, the following safety measures must be observed at all times: 1. Side rails may be operated only by care givers instructed in their use. 2. Make sure side rails – or elements of them – are either fully raised and locked or \ fully lowered. 3. During the adjustment of the mattress-frame, make sure that the patient is not touching the side rails. Also make absolutely sure that no limbs...

 Open the catalog to page 12
SMP-100ML-13

USER MANUAL MANUAL BED SMP 100ML 6.) Before using the bed for the first time Before the bed is put into service for the first time, this user’s manual must be closely read by all those responsible for nursing care. Before the bed is put into service for the first time, it is absolutely essential to carry out a functional test. Before first use, care givers must receive detailed instructions on the operation of the bed. In addition, care givers must be made fully aware of potential dangers that can arise in spite of the correct operation of the bed. 6.1) Functional test A functional test must...

 Open the catalog to page 13
SMP-100ML-14

USER MANUAL MANUAL BED SMP 100ML Follow these instructions when using cleaning agents and/or disinfectants: − Decontaminants in the prescribed concentrations may not exceed or fall below a pH value of 6-8. − They may not contain any corrosive or caustic substances. − They may not contain any substances that alter surface finishes or the Adhesive properties of plastics. − They may not affect the properties of lubricants. − Water hardness may not exceed 0.9 mmol/l (to 5° d). Fully desalinated water may not be used. Chloride < 100 ppm Silicate as Sio2 < 15 ppm Iron < 0,05 ppm Manganese < 0.01 ppm...

 Open the catalog to page 14
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.