LABO MATE 400 NEW CENTURY ARTICULATOR

LABO MATE 400 NEW CENTURY ARTICULATOR

LABO MATE 400 NEW CENTURY ARTICULATOR

Product catalog summary
Specifications:
  • The Labo Mate 400 features a centric needle that identifies the anterior centric point of Bonwill's triangle.
  • Item numbers for various components include: 02100-29 for the centric needle, 02100-14 for the support pin, and 02200 for the complete set.
  • The incisal pin, item number 02100-05, includes a scale for adjusting occlusive height.
  • Incisal guidance tables are available in different degrees: 0°, 5°, 10°, 20°, and adjustable, with corresponding item numbers.
Procedures:
  • The device is a non-Arcon type, with the condyle located at the upper component.
  • To prevent the condyle from dropping during lateral movement, rotate the rod inward.
  • Use the centric lock screw to fix the condyle for centric movement.
Adjustments:
  • Condyle angle can be adjusted between 0° and 50° by loosening the big wheel.
  • The Bennett angle is adjustable from 0° to 20° by unscrewing the small wheel.
  • Height can be raised by 0-5mm, with each scale representing 1mm.
Design Features:
  • Two foot stools allow for a 30° inclination.
  • The mobile design is space-saving.
See more

Catalog excerpts

LABO MATE 400 NEW CENTURY ARTICULATOR-1

Labo mate 400 Item No. 02100-14 You can put the support pin at the rear side without the incisal pin or at upper component for a clear view. Item NO. 02100-05 The incisal pin has a scale. It makes it easier to adjust the occlusive height. Item No. 02100-29 Centric needle points out the anterior centric point of Bonwill's triangle. Right Condyle Left Condyle Bonwill's Triangle Mandibular Incisal Item No. 0° - 02100-28A / 5° - 02100-28B / adjustable - 02100-28E 10° - 02100-28C / 20° - 02100-28D Different degrees of incisal guidance table : 0°、5°、10°、20°、adjustable. There's a mark to let it back the original position. adjustable (option)

 Open the catalog to page 1
LABO MATE 400 NEW CENTURY ARTICULATOR-2

Non-Arcon type, the condyle is at the upper component. Rotate the rod inward to prevent the condyle drops out from the track when doing lateral movement. Screw the centric lock screw to fix the condyle to do the centric movement. Condyle Angle Condyle angle (0° -50° ) Loosen the big wheel to change the condyle angle. The rubber bands at both sides help the condyle back to the centric position after the lateral or posterior movement. Bennett angle (0° -20° ) Unscrew the small wheel to adjust the Bennett angle. Also, we can raise the height a little bit (0-5mm, each scale is 1mm). Two foot stools...