LABO MATE 500 NEW CENTURY ARTICULATOR

LABO MATE 500 NEW CENTURY ARTICULATOR

LABO MATE 500 NEW CENTURY ARTICULATOR

Product catalog summary
Specifications:
The Labo Mate 500 features a handle that can be adjusted without loosening the screw by pulling it up. It includes a centric needle that indicates the anterior centric point of Bonwill's triangle. The device offers different degrees of incisal guidance: 0°, 5°, 10°, 20°, and adjustable, with corresponding item numbers for each degree. The incisal pin is scaled for easy occlusive height adjustment. The support pin can be positioned at the rear or upper component for a clear view.
Procedures:
To adjust the condyle angle (0° - 70°), loosen the screw on the upper component. For Bennett's angle (0° - 30°), loosen the Bennett's screw and adjust with the small handle. The device is of the Arcon type, with the condyle located at the lower component. Immediate side shift is possible by loosening screws with an Allen wrench and simulating the ligament with a rubber band.
Features:
The device allows for centric movement by pulling the centric lock to the back side. It can also perform lateral and protrusion movements by pushing it forward. Two foot stools enable a 30° inclination, and the mobile design is space-saving. The maximum width from the rear side is 146mm.
See more

Catalog excerpts

LABO MATE 500 NEW CENTURY ARTICULATOR-1

Item No. 02100-14 You can put the support pin at the rear side without the incisal pin or at upper component for a clear view. You can change the direction of the handle without loosen the screw by pulling it up. Item No. 02100-29 Centric needle points out the anterior centric point of Bonwill's triangle. Right Condyle Left Condyle The incisal pin has a scale. It makes it easier to adjust the occlusive height. Bonwill's Triangle Mandibular Incisal Item No. 0° - 02100-28A / 5° - 02100-28B / adjustable - 02100-28E 10° - 02100-28C / 20° - 02100-28D Different degrees of incisal guidance table : 0°、5°、10°、20°、adjustable. There's a mark to let it back the original position. adjustable (option)

 Open the catalog to page 1
LABO MATE 500 NEW CENTURY ARTICULATOR-2

Condyle Angle(0° -70° ) Loose the screw on the upper component, then change the angle you want. Bennett's Angle (0° -30° ) Loose the Bennett's screw, you can adjust the angle with the small handle. Note: As the picture, it is 0° . Arcon type The condyle is at the lower component. Immediate Side Shift Loose the screws with Allen wrench. Wide view f rom rear s ide. Maxim um w idth -- 146 mm. Simulate the ligament with the rubber band. It allows the condyle going back to the centric position. unlocked Pull the centric lock to the back side to lock the condyle. And we can do the centric movement...

 Open the catalog to page 2