diaton

diaton

diaton

Product catalog summary
Overview: The Diaton IOP measuring device is a hand-held, portable tool designed for measuring intraocular pressure (IOP) through the eyelid, eliminating the need for corneal contact. This makes it particularly effective in situations where standard tonometry is not feasible.
Key Features:
  • Measures IOP through the eyelid, avoiding corneal contact.
  • No anesthesia or sterilization required.
  • Usable in both sitting and reclined positions without removing contact lenses.
  • Hand-held and easily portable.
Ideal Use Cases:
  • Pediatric patients.
  • Patients with chronic conjunctivitis.
  • Post-LASIK, keratoprothesis, or other corneal surgeries.
  • Corneal erosions or edema.
  • Eye trauma, including emergency room scenarios.
Specifications:
  • Measurement Range: 5 - 60 mmHg.
  • Measurement Error: 5 - 20 mmHg ± 2 mmHg; 20 – 60 mmHg ± 10%.
  • Maximum Time of Measurement: 3 seconds.
  • Minimum Measurements per Battery Set: 1,500 measurements.
  • Supply Voltage: 3 VDC.
  • Weight: 0.2 lbs / 89 g.
  • Length: 6.9 in. / 17.4 cm.
Patents: United States Patent No. US 6,394,954; Japan Patent No. 3593314; Russia Patent No. 2123798.
Contact Information: Sonomed Escalon, 1979 Marcus Avenue C105, Lake Success, NY 11042, USA. Phone: 800-227-1285 or 516-354-0900. Email: [email protected]. Website: www.sonomedescalon.com.
See more

Catalog excerpts

diaton-1

Hand-held and easy to use Measures through the eyelid – no corneal contact Effective in cases where standard tonometry cannot be reliably used

 Open the catalog to page 1
diaton-2

Ideal for cases where standard tonometry cannot be reliably used: • Pediatric patients • Chronic conjunctivitis • Following LASIK, keratoprothesis, or other corneal surgery • Corneal erosions or edema • Eye trauma, including emergency room patients Measures through the eyelid– no corneal contact, no anesthesia required, and no need for sterilization Easy to use in either sitting or reclined position with no need to remove contact lenses Hand-held and easily portable Specifications Measurement Range Measurement Error 5 - 20 mmHg 5 - 60 mmHg ± 2 mmHg 20 – 60 mmHg ± 10% Max. Time of Measurement...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.