SH800S

SH800S
1 / 14 PagesView full catalog

SH800S

Product catalog summary
Overview: The SH800S Cell Sorter by Sony Biotechnology Inc. is a benchtop device designed for sorting various cell sizes using microfluidics sorting chips. It offers advanced automation for setup, acquisition, sorting, and analysis, ensuring user-friendliness and precision.
Specifications: The system includes up to four collinear excitation lasers (488 nm, 405 nm, 561 nm, and 638 nm) and six fluorescence detectors. It supports sorting into tubes and 96- and 384-well plates, with data exportable in FCS 3.0 and 3.1 formats. The device features a collinear optical system and detection parameters for 6 fluorescent and 2 scatter channels, using 8-channel 20-bit ADCs at 110MHz for pulse measurement.
Automation and Ease of Use: The SH800S offers one-touch setup with automated chip loading and positioning, optical axis adjustment, droplet calibration, and side stream calibration. It uses patented CoreFinder™ technology and features a 7-inch LCD monitor for easy operation.
Software: The intuitive software includes wizards for step-by-step guidance through startup, multicolor compensation, sorting, and cleaning. It supports various sorting methods and vessels, and provides tools for data analysis and export.
Biosafety Options: An optional Class II biosafety cabinet, custom-designed for the SH800S, meets international standards for personnel and product protection, including a built-in aerosol management system.
Applications: The SH800S supports a range of applications and cell sizes, offering high fluorescence sensitivity and resolution, suitable for immunophenotyping assays and advanced sorting techniques.
Key Features: The system's compact design, automation, and flexibility make it ideal for individual and core labs. Optional e-beam sterilized consumables are available to prevent cross-contamination.
Fluidics: The system supports single, auto-loading sample tubes of various sizes and offers 2-way tube sorting, multiwell plates, PCR tubes, and slides. Temperature control ranges from 5°C to 37°C with an agitation unit capable of 300 rpm.
Performance: The sorter achieves an event rate of 100,000 events per second, with sorting speeds using a 70 µm chip at 50 kHz reaching 12,000 events per second with >98% purity and >80% yield. Scatter resolution is 0.5 µm, and fluorescence resolution is <2.5% HPCV.
Ancillary Features: The device dimensions are 21.7” x 21.7” x 28.4”, with a fluidics cart weighing 71 lb. It includes a 7-inch LCD panel and operates on a power supply of 100-240 V, consuming up to 500 W. The operating temperature range is 17.5 to 27.5°C with 20 to 80% relative humidity.
Compliance and Safety: The device complies with environmental standards (RoHS) and safety standards (UL, CE, CSA). It operates on Microsoft Windows 8 Professional, 64-bit, and uses Flow Cytometry Standard (FCS) 3.0 or 3.1 for data file structure.
Fluorescent Protein Analysis: The document includes analysis of human cell lines co-expressing various fluorescent proteins and sorting and viability analysis of mouse embryonic stem cells expressing Isl1Cre-tdTomato.
Filter Guide: Details on filter sets for various fluorochromes are provided, including specific filters for EGFP, FITC, Alexa Fluor, and others.
Contact Information: Contact details for Sony Biotechnology in Japan, North America, and Europe are provided for sales and support.
See more

Catalog excerpts

SH800S-2

SH800S Cell Sorter Sorting Made Simple™ The benchtop SH800S cell sorter permits sorting of a wide range of cell sizes and applications using the 70 µm, 100 µm, and 130 µm microfluidics sorting chips. This novel, chip-based design is fully integrated with comprehensive fluidics controls and advanced automation for set-up, acquisition, sort and analysis to make sorting less subjective, more precise and easier to use. System software is intuitive and supports sorting into tubes and 96- and 384-well plates. The software generates FCS 3.0 and FCS 3.1 files that also can be exported to third party...

 Open the catalog to page 2
SH800S-3

Automation from Set-up to Analysis The SH800S provides the highest level of automation and ease of use available in a cell sorter. Researchers can accurately set-up, calibrate and monitor sorting with a push of a button. This delivers true ease of operation to save time and improve consistency of results. A novel microfluidics sorting chip uses patented CoreFinder™ technology to automate key steps of instrument setup and operation streamlining workflow. The system is versatile, allowing researchers to sort of a wide range of cell sizes to accommodate application requirements. Chip sizes include...

 Open the catalog to page 3
SH800S-4

Automated Chip Loading & Positioning Automated Optical Axis Adjustment Automated Droplet Calibration System set-up begins with a one-touch install to load the microfluidics flow cell chip. Actuators ensure precise positioning of the chip inside the chip loader. Sheath, sample and vacuum lines connect and seal automatically to their respective ports once the chip is loaded. Made of durable plastic the chip is easy to replace when needed. The alignment of the chip to the lasers is optimized automatically during setup using the Sony patented Blu-Ray™ technology for aligning and tracking laser position....

 Open the catalog to page 4
SH800S-5

Software Software, sensors and CoreFinder patented technology provide automation across the workflow from set up to shut down to ensure consistency, save time and improve the accuracy of results. The interface is designed with ribbon tabs that logically organize features to make them rapidly accessible. An experiment-centric approach makes the software easy to teach, learn and use. Software wizards include step-wise workflows that guide users through start up, multicolor compensation, sorting and system cleaning. Since the system simplifies even advanced sorting techniques it can be used by researchers...

 Open the catalog to page 5
SH800S-6

Experiment Settings Data Analysis and Display Users can create an experiment by selecting a new template, a recent experiment, or a shared template (public) from the experiment window. If a new template is selected the user is guided via dialogs to choose experiment settings such as sample groups, tubes and pulse parameters for data acquisition. Once a template is selected the user can start acquisition or compensation wizard. Data is displayed as dot plots and histograms on worksheets and events can be marked using gates. The software has a number of tools to select, adjust, label and measure...

 Open the catalog to page 6
SH800S-7

Biosafety Cabinet The BCC300AMS Class II biosafety cabinet custom designed for SH800S by the Baker Company is available as an option to provide personnel and product protection. The cabinet measures 1,180 mm (W) x 991 mm (D) x 2,239 mm (H). Biosafety Safety Standards Compliance The cabinet was tested by the Baker Company using microbiological assays with the SH800S sorter inside the work area. The testing concluded that the Biosafety Cabinet with the SH800S inside met several international biosafety standards including National Sanitation Foundation Standard 49 (NSF49), and the European Standard...

 Open the catalog to page 7
SH800S-8

E-Beam Sterilized Consumables Exchangeable Sample Fluidics Versatile Application Support For applications where cross-contamination between samples or with external biological entities are a factor, optional e-beam sterilized consumables including chip, setup beads and sample lines can be used to streamline workflow. The SH800S sorting chip is an integrated flow cell-nozzle assembly. It contains microfluidic channels for controlling the flow of sample and sheath fluid. The sample is interrogated by the lasers within the chip before it passes through the nozzle for sorting. Easy installation Chip...

 Open the catalog to page 8
SH800S-9

Applications Resolution and Sensitivity 653 653 Events Events Events Events Events Events Events Events A. Fluorescence sensitivity MESF values measured using Spherotech 8 peak beads are: FITC 120 and PE 110. B. Fluorescence resolution was measured using propidium iodide (PI) stained chicken erythrocyte nuclei (CEN). Coefficient of variation of <2.5% was observed for the G0/G1 peak. Singlets Singlets Singlets Singlets Events Events PE-H-Compensated PE-H-Compensated Events Events Singlets: Singlets: 68.45% 68.45% Singlets: Singlets: 68.45% 68.45% Immunophenotyping Assays Distinct resolution of...

 Open the catalog to page 9
SH800S-10

Fluorescent Protein Analysis D Human cell lines co-expressing GFP, YFP, dsRed and CFP using the fluorescent protein optical filters is shown. Refer to the filter guides for the fluorescent protein filter sets. Sorting and Viability Analysis DAPI-A-Compensated DAPI-A-Compensated DAPI-A-Compensated DAPI-A-Compensated DAPI-A-Compensated DAPI-A-Compensated Live Cells Live Cells Live Cells: 87.69% Live Cells: 87.69% FSC-A FSC-A tdTomato-A-Compensated tdTomato-A-Compensated DAPI-A-Compensated DAPI-A-Compensated DAPI-A-Compensated DAPI-A-Compensated DAPI-A-Compensated DAPI-A-Compensated Sorting and...

 Open the catalog to page 10
SH800S-11

Small Particle Resolution High speed sorting of E.coli using 70um sorting chip- Concentrated sample of E.coli cells was sorted at a threshold event rate of 30,000 events/sec at a sort setting of 50kHz and 40psi. Post sort analysis shows that >95% purity was obtained.

 Open the catalog to page 11
SH800S-12

Fluorochrome Guide Filter Set 1

 Open the catalog to page 12
SH800S-14

North America/International 1730 North First Street San Jose, CA 95112 U.S.A. Voice: +1 800-275-5963 FAX: +1 408-352-4130 [email protected] http://www.sonybiotechnology.com 1-7-1, Konan, Minato-Ku, Tokyo, 108-0075 Japan Tel: +81 120-677-010 Fax:+81 120-388-060 [email protected] http://www.sony.co.jp/LS The Heights, Brooklands. Weybridge, Surrey, KT13 0XW, UK Tel: +44 (0) 1932 817448 [email protected] ©2016 Sony Biotechnology Inc. All rights reserved. Sony, the Sony logo, Blu-ray, Sorting Made Simple and CoreFinder, are trademarks of Sony Corporation. Alexa...