AdvancedVascular Diagnostics Arterial and Venous Diagnostic Solutions
Open the catalog to page 1SOT Medical Systems SOT Medical Systems is engaged in medical business since more than 37 years within Austria as well as internationally. In 1991 the family-owned company started operating in the fields of angiology, phlebology and cardiology. Since 1999, a system for the fast and reliable diagnosis of PAD patients has been developed: The AngE – AngioExperienceTM System. Due to its modularity, it constitutes the ideal expertsolution for angiologists, phlebologists, vascular surgeons and for the diagnosis of diabetic patients. "We Support General and Specialist Practitioners to Early Detect Blood...
Open the catalog to page 2The AngE-System is conceived as modular solution for vascular and cardiovascular diagnostics. This enables us to provide custom-made configurations that can be adapted to individual diagnostic requirements at any time. AngE™ABI+ AngE™COMPLETE 1 -Minute Vascular Screening 2-Channel Arterial and Venous PPG Page 3 Fully equipped Vascular Diagnostics Lab Page 9 Patient Management Venous & Arterial PPG Temperature Recording TBI and Toe Pressure ABI, PWV and PWI™ Heart Rate Variability Venous Occlusion Plethysmography Bidirectional Doppler Your Advantages when choosing SOTFlexibility A modular system...
Open the catalog to page 3Venous Measurements in Pocket Size Assessment of Chronic Venous Insufficiency - CVI 2 Optical USB-Powered PPG Sensors Temperature Probes Venous Function Tests The AngE Phlebo is a 2-channel D-PPG/LRR device that uses two IR-sensors to perform venous function measurements, evaluating Muscle Pump and Venous Valves. Two times 2-channel Venous Function Test (without and with Tourniquet) with determination of Pump Volume (V0), Fill Time (T0), Half-Life Time (T50) and Temperature. See how it's applied Access Videos, Report Samples and More
Open the catalog to page 4Pump Volume and Vein Fill Time Deep and Superficial Veins Automatic calculation of the pump volume (V0), With the included set of Tourniquet cuffs and manual the venous fill time (T0), as well as the venous half-fill time (T50). manometer pump, the system can differentiate between superficial and deep venous problems. The simple traffic light display allows for a fast assessment of Chronic Venous Insufficiency – CVI. "The AngE Phlebo is the state-of-art, haemodynamically significant D-PPG system for venous diagnostics. This non-invasive functional investigation has always helped me accurately examine venous...
Open the catalog to page 5AngE™ABI ^ Easy to Use and Evaluate ✓ Peripheral Arterial and Venous Tests^ macOS ft and Windows SS compatible - store directly to EHR/PACS ———- ■ advancc ''tnwncwj V>*cul»r Olagn <S> ^ g> <S> as ce h as ce T1 (CHI): Wrist left 110/84 IIOmmHg AI-Assisted Vascular Score I Ampl II Easy interpretation of vascular health, regardless of blood pressure or calcified vessels. Vascular Health Score Cardiac Output Rise Time Ankle Amplitude Diff. Ankle Time Shift 2 ms Arms .-4-Channel simultaneous Pulse Wave Recording on Arms and Ankles.
Open the catalog to page 6Vascular Health Screening Included Parameters Related Conditions ABI – Ankle Brachial Index PAD – Peripheral Arterial Disease PWV – Pulse Wave Velocity Atherosclerosis & Arterial Stiffnes PWI™ – Pulse Wave Index Limb Ischemia Segmental Pressures Interarm Blood Pressure (IAD) Diabetic Foot Ulcera Optional: TBI & Systolic Toe Pressure Arhythmic Heartbeat with Skin Temperature TOS – Thoracic Outlet Syndrome Optional: HRV – Heart Rate Variability & ECG Raynaud’s Syndrome See how it's applied Access Videos, Report Samples and More Mobile trolley and tablet computer optional.
Open the catalog to page 7AngE™ABI+Comprehensive Vascular Screening ^ Early Diabetic Foot detection in under 3 Minutes Determine ABI, TBI, Toe Pressure, Pulse Wave Velocity, Heart Rate Variability and more ✓ Blood Pressure independent PWI™ - Pulse Wave Index Micro- and Macrocirculation to estimate Wound Healing success. (?) Oscillography (PVR) Vascular Screening (ABI* PPG *eCG) g) © (T) 39 • RIGHT _ LEFT Cardiac Output Amplitude Diff. Ankle Interarm BP Diff. Rise Time Ankle Time Shift I Years © 145 ms Right © 3 ms Legs 6-Channel Simultaneous Pulse Wave Recording on Wrists, Ankles and Toes using the TOPP-Method (Tissue...
Open the catalog to page 8Comprehensive Screening AngE ABI+ combines four measuring cuffs and two The measurement can be conducted easily by following optical sensors to enable the measurement on six only a few steps and without significant stress for the measuring spots simultaneously. This creates diverse possibilities to detect blood flow disorders within the terminal vessels as well as to assess the wound healing success, especially in diabetic patients. "The high sensitivity of the optical sensors allow for a good documentation of the pulse waves, even with marginal blood flow. Given the virtually unfiltered display of...
Open the catalog to page 9COMPLETE The All-in-One Vascular Diagnostic System Cardiovascular Testing By recording the R-wave it allows the calculation of Heart Rate Variability and Pulse Wave Velocity. PPG-Sensors Optical sensors for venous and arterial measurements of the microcirculation. Phlebodynamometry Invasive venous- and compartment pressure measurements with one or two channels. 8-Channel Segmental Oscillography Each measuring track can be recorded and evaluated separately. This allows for the localization of occlusions as well as fully automated calculation of pulse wave parameters within 45 seconds. Venous Air...
Open the catalog to page 10Multiple Cuff Sizes AngE COMPLETE comes with a variety of cuff sizes, suitable for every patient type and medical condition, such as lymphatic legs. 8-Channel Oscillography The AngE Pro 8 allows recording pulsations simultaneously or segmentally with up to eight cuffs at the same time. 4 and 8 MHz Doppler Conduct Biderectional Doppler pressure measurements on up to 16 individual arteries. DICOM and HL7 compatible The AngE Software provides out-of-the box compatibility with DICOM and HL7 interfaces for easy connection to the Hospital Information HIS/EHR system. Multi-Channel Stress Tests Through...