History Value Proposition Treatment Solution Focus Commitment
1 / 12Pages

Catalog excerpts

History Value Proposition Treatment Solution Focus Commitment - 1

Predictable Anterior Aesthetics with the INVERTA™ Implant – A Dossier Optimizing Predictable Anterior Aesthetics with an Innovative Body-Shift™ Implant Des

Open the catalog to page 1
History Value Proposition Treatment Solution Focus Commitment - 2

Introducing the INVERTA™ Implant A NEW Implant Designed for Optimizing Aesthetics in Maxillary Anterior Extraction Socket Sites Body-Shift™ Design Subcrestal Angle Correction® INVERTA Site Preparation Research Summaries Coronal Chamber for Bone Growth The Background of Breakthrough Innovations – Evolution of the INVERTA™ Implant Case Studies INVERTA Product Breadth

Open the catalog to page 2
History Value Proposition Treatment Solution Focus Commitment - 3

INVERTA Implant Design History Initial commercial release consists of INVERTA™ Co-Axis® and Straight Deep Conical and External Hex configurations. Additional configurations planned for release are designs in PROVATA™ Internal Hex connection and narrower, and wide bodies. - Graham Blackbeard A foreword based on the account of Dr. Stephen Chu, Graham Blackbeard, and Jeremy Pitman In 2016 Dr. Stephen Chu (Prosthodontist, New York, USA) and Graham Blackbeard, Engineer, founder and managing director of Southern Implants, Pty (Republic of South Africa) met for discussions about dental implant...

Open the catalog to page 3
History Value Proposition Treatment Solution Focus Commitment - 4

The INVERTA™ Difference Deep Conical Internal Connection INVERTA™ Site Preparation External Hex Popular Co-Axis Feature ® Shown here for a 13mm x Ø3.5/4.5mm Deep Conical INVERTA Implant. Built-in 12° Subcrestal Angle Correction® without using angled abutments resulting in greater facial soft-tissue volume and Coronal Thread All INVERTA Implants feature a shallow square thread at the coronal aspect designed for blood clot and graft stability and thereafter the ability to effectively transfer load to the bone. Coronal aspect is narrow and tapers SInergy™ Surface with 20-Year History outward...

Open the catalog to page 4
History Value Proposition Treatment Solution Focus Commitment - 5

Research Summary: Evaluation of an Innovative Hybrid Macrogeometry Dental Implant in Immediate Extraction Sockets: A Histomorphometric Pilot Study in Foxhound Dogs. Nevins M, Chu SJ, Jang W, Kim DM. Summary by: P Östman, DDS, PhD, MD .O. A preclinical pilot study was performed to evaluate the safety, efficacy, primary stability, and wound healing of a hybrid dental implant with a unique macrogeometry design in which the coronal section is narrower and cylinder-shaped followed by a wider, tapered apical portion, each comprising approximately one half the length of the implant. Eighteen...

Open the catalog to page 5
History Value Proposition Treatment Solution Focus Commitment - 6

Utilizing the INVERTA™ Co-Axis® Implant to Achieve Predictable and Highly Aesthetic Outcomes “The INVERTA Implant design represents a paradigm shift in biologic and aesthetic thinking. Combining apical stability with an inverted Body-Shift design allows for coronal spacing, optimizing the ability to provide more bone and ultimately superior aesthetics for patients.” Clinical Treatment By: Stephen J. Chu, DMD, MSD, CDT & Dennis P Tarnow, DDS . Case Overview A 47 year old female patient presented with a chief complaint of discoloration of tooth #9 and #10. Radiographic and clinical...

Open the catalog to page 6
History Value Proposition Treatment Solution Focus Commitment - 7

Immediate Implant Placement with 18-Month Follow-Up and No Buccal Recession “To be able to use IINVERTA Implants in aesthetically challenging cases gives me a predictable outcome with limited buccal recession and healthy soft tissue.” Clinical Treatment By: P.O. Östman, DDS, PhD, MD Case Overview A 35 year old male patient presented with a crown and root fracture endodontic complication. Radiographs and clinical examination resulted in a diagnosis of a mobile tooth #9 with horizontal root fracture, endodontic complication, biotype 2 with keratinized mucosa, and tooth #8 enamel/dentin...

Open the catalog to page 7
History Value Proposition Treatment Solution Focus Commitment - 8

Achieving Predictable Aesthetic Results When Immediately Loading the Anterior Maxilla Extraction Socket Achieving High Primary Stability After Immediate Implant Placement in the Aesthetic Zone Costa Nicolopoulos, BDS, FFD (MFOS) (Oral Maxillofacial Surgeon) & Petros Yuvanoglu, DMD (Prosthodontist) Case Overview Case Overview A 38 year old male patient presented with mobility in anterior. Radiographs and clinical examination resulted in a diagnosis of an unrestorable, fractured root at tooth #8. Based on diagnosis, treating clinicians recommended extraction of the fractured tooth, immediate...

Open the catalog to page 8
History Value Proposition Treatment Solution Focus Commitment - 9

Immediate implant placement and provisionalization with GBR/GTR Treating the Endodontic Tooth with a Long-Term, Aesthetic Option Case Overview Case Overview A 22 year old female presented complaining about an infection and short front tooth. Radiographs and clinical examination resulted in a diagnosis of severe root resorption at tooth #9, 2-3mm atrophy of facial plate, localized moderate periodontitis with CAP #9, non-restorable. Based on the diagnosis the treating clinician recommended extraction of tooth #9, Guided Bone Regeneration (GBR), Guided Tissue Regeneration (GTR) and implant...

Open the catalog to page 9
History Value Proposition Treatment Solution Focus Commitment - 10

Immediate Extraction with Implant Placement and Immediate Non-Occlusal Loading Achieving High Primary Stability After Immediate Implant Placement in the Aesthetic Zone Michael Will, DDS, MD, FACS Case Overview Case Overview A 22 year old male patient presented unhappy with his anterior aesthetics. Radiographs and clinical examination resulted in a diagnosis of a crown fracture on the palatal side, composite build-up with defective margins and recurrent decay of tooth #9. Based on diagnosis, treating clinician recommended immediate extraction, implant placement with non-occlusal load using a...

Open the catalog to page 10
History Value Proposition Treatment Solution Focus Commitment - 11

INVERTA™ Product Breadth Acknowledgment It isn’t often that a chance meeting, a short three years ago, would lead to a groundbreaking innovation in optimizing predictable aesthetics. Available in INVERTA Co-Axis and Straight Deep Conical and External Hex Implants. Additional configurations coming soon are designs in PROVATA™ Internal Hex connection and narrower, and wide bodies. ® Three years to design, test, research and commercialize a line of products is unheard-of, yet, INVERTA happened! By combining Southern Implants expertise and willingness to seize an opportunity to optimize patient...

Open the catalog to page 11