SOUTHERN IMPLANTS’ Innovative Treatment Solutions INTERNAL HEX Implants Product Catalogue
Open the catalog to page 1Southern Implants is a leading provider of unique and innovative dental implant products with a focus on top-end professional users who want more choices. Southern's expertise in research, development and manufacturing of dental implants allows us to provide Innovative Treatment Solutions that will reduce treatment times and improve patient outcomes. Striving for excellence and meeting customer needs, has led to our wide product range characterized by Unique and Innovative products which include; - Multiple interfaces, to suit customer preference. - INVERTA™ implant, featuring a body-shift design,...
Open the catalog to page 2CO-AXIS® 04.2mm Co-Axis Implants (Tapered) Implants & Surgical Components Page 10 Prosthetic Flowchart Page 11 Site Preparation & Instrumentation Page 12 Platform Matched Prosthetics for 05mm implants Page 14 Prosthetic Flowchart Page 15 Insertion Tool Depth Markings Page 15 Drill Information Page 16 Insertion Tool Protocol Implant Placement Procedure for Straight Internal Hex implants Page 16 Co-Axis® Fixture Mount Removal Protocol Page 16 Driver Information Page 17 Instrument Trays l-INT-HEX-EG Page 18 Torque Table for Southern Screws Page 21 Implant Information Page 22 Explanation of Symbols...
Open the catalog to page 3NOTE: • Images are for illustration purposes only and do not necessarily accurately represent the product. • All dimensions in this catalogue are in mm, unless otherwise specified. • Not all products are cleared for sale in all countries.
Open the catalog to page 4Implants are available in lengths of: NOTE: Implant dimensions and information - page 22 ITEM CODE ITEM CODE ITEM CODE TAPERED IMPLANT LENGTHS (in mm) TAPERED IMPLANT LENGTHS (inmm) TAPERED IMPLANT LENGTHS pnmm) Surgical Components Cover Screw
Open the catalog to page 6Direct Healing Prosthetic Components Retaining Screws Indirect Compact Conical Abutments MC-M TC-M (engaging) TC-NM (non-engaging) GC-EM (engaging) GC-NM (non-engaging) (digital analogue) DIRECT Abutments SCANNABLE Abutments PASSIVE Abutments TCA-M (engaging) CAB-M (engaging) CAB-NM (non-engaging) CIA-EM (engaging) CIA-NM (non-engaging) Brass (1.27 Hex) ‘'(Blackened and for laboratory use only) PA-EM-S (engaging) PA-NM-S (non-engaging) Titanium TMCSL (long version) Brass (1.27 Hex) "(Blackened - for laboratory use only) NOTE: Refer to CAT-1189 for Equator Overdenture options.
Open the catalog to page 7(All illustrations are for 13mm implants) NOTE: • Site preparation sequence recommended by Southern Implants does not replace the judgement and experience of the surgeon. • Refer to page 16 for the Fixture Mount Removal Protocol. Placement Tool l-WI-SS I-HD-22U-S/M/L l-QDI-S/M/L Pi :: I! Wrench insert NOTE: • Refer to CAT-1155 for more information on wrench insert converters • Most instruments are available in various lengths
Open the catalog to page 8IM-T42-12d Implants are pre-mounted and available in lengths of: note: implant dimensions and information - page 22 ITEM CODE IMPLANT LENGTHS irnnm) Cover Screw Healing Abutments
Open the catalog to page 10Healing Abutments Impression Copings Laboratory Analogues Prosthetic Components Retaining Screws DIRECT Abutments GC-EM (engaging) GC-NM (non-engaging) TCA-M (engaging) SFT-M (scanning flag) CAB-M (engaging) CAB-NM (non-engaging) (digital analogue) SCANNABLE Abutments Brass (1.27 Hex) ‘'(Blackened and for laboratory use only) PASSIVE Abutments Compact Conical Abutments MC-M (digital analogue) Ttanlum TMCSL (long version) NOTE: Refer to CAT-1189 for Equator Overdenture options.
Open the catalog to page 1104.2mm Tapered Co-Axis8(IM-T42-12d) (illustration is for 13mm implants) NOTE: • Site preparation sequence recommended by Southern Implants does not replace the judgement and experience of the surgeon. • Refer to page 16 for the Fixture Mount Removal Protocol. Placement Tool l-HM-S / M / L l-WI-NI-S / M / L l-WI-CST l-WI-SS ta Wrench insert For Handpiece inserts (Latch-type) featuring the W&H hex DriversI-HD-22U-S/M/L l-QDI-S/M/LFinal tapered drill position PLEASE NOTE: Point 1 This comer of the drill is to be at bone level. Point 2 This corner of the drill will be subcrestal. 1.22 Universal Quad...
Open the catalog to page 12PLATFORM MATCHED PROSTHETICS for 05mm implants
Open the catalog to page 13In applications of the Internal Hex 05mm implants, for single posterior teeth, where the patient is known to have a very strong bite force, the clinician may choose to follow this “Platform Matched” approach. This approach uses the implant platform, in order to give the single tooth prosthetics greater stability. Warning: These Platform Matched Prosthetics are not compatible with Internal Hex 03.7mm/ 04.2mm implants or Internal Hex Co-Axis™ 04.2mm implants. Standard internal cone Platform Matched interfacing prosthetics Prosthetics Compatible with: NOTE: Implant dimensions and Information - page...
Open the catalog to page 14Direct Healing Impression Abutments Copings Laboratory Analogues Prosthetic Components Retaining Screws (pick-up) (transfer) SCANNABLE Abutments Gold (Quad) PASSIVE Abutments Brass (1.27 Hex) ‘(Blackened and for laboratory use only) Passive Abutment Screws PA-M-18T PA-Q-18G PA-M-18B* Titanium Gold *(Blackened - for laboratory use only) INSERTION TOOL DEPTH MARKINGS IT l-HM-L used tor illustration purposes l-WI-M-L used tor illustration purposes NOTE: • Laser markings at 3mm, 5mm, 6mm and 9mm from implant platform. • Refer to CAT-1201 for Insertion Tool markings and depths. Important: The PEEK...
Open the catalog to page 15INSERTION TOOL PROTOCOL Implant Placement Procedure for Straight Internal Hex implants 1. The tool l-HM-S / M / L is used to pick up the implant from the packaging. 2. The hexagon of the insertion tool in the implant must be fully engaged before torque is applied, to prevent any damage [The hexagon is fully engaged when the straight portion of the hexagon tool Is almost completely sunken In the implant (fig-VY 3. The implant is placed in the prepared site and screwed in with a motor unit at 15rpm while applying downwards pressure. The tool l-HM-S / M / L is used to pick up the implant from the...
Open the catalog to page 1628 Pages