Capnography Module
1 /5Pages

Capnography Module

Capnography Module
1 /5Pages

Catalog excerpts

Capnography Module -1

The Capnography Module (92517) supports mainstream and sidestream monitoring modes and provides clinicians with the ability to see the carbon dioxide levels and Respiration Rate of a patient. It is designed to measure the concentration of carbon dioxide in a gas mixture and to aid in determining the patient’s ventilatory, circulatory, and metabolic status. Module use is restricted to one patient at a time Measurement of Respiration Rate and Carbon Dioxide Continuously measures end-tidal CO2, minimum CO2, and respiration rate N2O and O2 Compensation Compensates for the presence of increased levels of nitrous oxide (N2O) and oxygen (O2) assuring measurement accuracy Pressure Compensation Automatically compensates for ambient barometric pressure assuring measurement accuracy

 Open the catalog to page 1
Capnography Module -2

Data Sheet Carbon Dioxide Sidestream — FiO2 and ETCO2 are displayed after one breath and have a continuously updated breath average. ET will typically decrease below nominal value (ETnom ) when respiration rate (RR) exceeds the RR threshold (RRth) according to the following formula: Sidestream —CO2: ET=ETnom x 125/RR for RRth > 125 Mainstream — ETCO2 will be within specification for all respiration rates up to 150 Measured at I/E ratio 1:1 using breath simulator according to EN ISO 80601-2-55 fig. 201.101 Measurement Rise <200 msec typically Values Inspired/expired Gas Gross Effects <0.2% (O2,...

 Open the catalog to page 2
Capnography Module -3

Data Sheet Capnography Module v1.00 Warm Up <30 seconds following power on or a change in the operating mode between sidestream and mainstream for concentration reporting and full accuracy specification Sample Line Flow Rates 50 ml/min ±10 ml/min Total System Response Sidestream: <3 seconds Time Mainstream: <1 second CO2 Waveform Scales Selectable at 0 to 120 mmHg, 0 to 100 mmHg, 0 to 80 mmHg, 0 to 60 mmHg, Waveform Speeds Selectable at 25, 12.5, 6.25, 3.12, or 1.56 mm/second Measurement Units %, mmHg, kPa for CO2; BPM for respiration rate Alarms User-selectable; respiration rate (high and low...

 Open the catalog to page 3
Capnography Module -4

Data Sheet Ambient Humidity <4 kPa H2O (non-condensing), 95% RH at 30° C Ambient Humidity 5 to 100% RH (condensing), 100% RH at 40° C* *After condensation, store the unit for more than 24 hours in an environment with relative moisture content below 95% RH (non-condensing) Atmospheric Pressure 18.6 to 100kPa, 0 to 11,760 meters (0 to 38000 feet) Water Ingress Meets EN 60529 IPX1 only when installed in 91393 Xprezzon and 91390 Qube patient monitors Spacelabs Healthcare products specific documentation is available at https://www.sDacelabshealthcare.com/manuals. For a full list of available supplies...

 Open the catalog to page 4
Capnography Module -5

Data Sheet Capnography Module v1.00 Capnography Module complies with the following standards: We are continuously improving our products. Specifications are subject to change without notice. Product images are provided for general reference. This product may not be available for sale in all countries. Please refer to https://www.spacelabshealthcare.com/trademarks for a full listing of Spacelabs Healthcare trademarks. Other brands and product names used herein are trademarks of their respective owners. 35301 SE Center Street, Snoqualmie, WA 98065, USA | T: +1 425 396 3300 | F: +1 425 396 3301

 Open the catalog to page 5

All Spacelabs Healthcare catalogs and technical brochures

  1. SL BISx

    4  Pages

  2. Pathfinder SL

    8  Pages

  3. Qube

    6  Pages

  4. Eclipse Pro

    8  Pages

  5. SvO 2 /ScvO 2

    4  Pages

  6. XPREZZON

    8  Pages

  7. Qube Mini

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.