Data Sheet Command Module 2.8 The Spacelabs 91496 Command Module is designed to provide a flexible selection of clinical measurements and compatibility with Spacelabs patient monitors. Choose the Command Module measurement offering based on your care unit needs or patient acuity. Durable and lightweight, Command Modules can easily be moved between monitors.

Open the catalog to page 1
Ultraview SL™ Command Module - 2

Data Sheet Available leads Measurement range Adult/Pediatric/Neonate: 15 to 300 bpm ECG size Adjustable from 0.5 to 10 mV/cm Numeric update rate Every 3 seconds or immediately at onset of alarm Heart rate accuracy ±1% or 3 bpm (whichever is greater) Frequency range • Monitoring: 0.5 to 40 Hz ±10% Sample rate 896 samples per second Arrhythmia Atrial Fibrillation, Asystole, Couplet, Paroxysmal Supraventricular Tachycardia, Pause, classifications Ventricular Ectopic, Ventricular Fibrillation, Ventricular Run Diagnostic ECG 12-leads; standard or Cabrera format Diagnostic sample rate 500 samples...

Open the catalog to page 2
Ultraview SL™ Command Module - 3

Data Sheet Input impedance 2,000 Q minimum Connector hlol supports TT-253 plug, P/N 354171-001, for connection to external device Input display Defibrillator sync marker is displayed with the return signal for synchronization of defibrillators Analog output • Invasive pressure (ART, PRS, UA, UV): 10 mV/mmHg (±5%) • Other pressure labels: 25 mV/mmHg (±5%) Pacemaker pulses Not included Connector hlo2 supports TT-253 plug, P/N 354171-001, for connection to external device Space/abs Healthcare does not provide interface cables to third party equipment. Cables constructed for use with 354171-001...

Open the catalog to page 3
Ultraview SL™ Command Module - 4

Data Sheet Measurement method Oscillometric, step-deflation method Measurement Automatic interval, manual Measurement read <45 seconds, typical Pulse measurement 25 to 255 bpm range Measurement range • Adult/Pediatric 4: 30 to 260 mmHg (4 to 34.7 kPa) (systolic/diastolic/ • Pediatric 2/3: 30 to 190 mmHg (4 to 25.4 kPa) mean) • Neonate/Pediatric 1: 15 to 140 mmHg (2 kPa to 18.7 kPa) Accuracy • Standard deviation ±7.3 mmHg • Mean error ±4.5 mmHg • Meets or exceeds ANSI/AAMI standard SP-10 Initial cuff inflation • Adult/Pediatric 4: 170 mmHg Maximum cuff inflation • Adult/Pediatric 2/3/4: 290...

Open the catalog to page 4
Ultraview SL™ Command Module - 5

Data Sheet Command Module 2.8 (91496)Cardiac Output (CO)Measurement method Thermodilution Parameter Cardiac output, blood temperature, injectate temperature Measurement range • Cardiac output: 0.1 to 18 L/min Calculated values Body Surface Area (BSA), Cardiac Index (CI), Stroke Volume (SV), Stroke Volume Index (SVI), Systemic Vascular Resistance (SVR), Pulmonary Vascular Resistance (PVR), Left Ventricular Stroke Work (LVSW), Right Ventricular Stroke Work (RVSW), Systemic Vascular Resistance Index (SVRI), Pulmonary Vascular Resistance Index (PVRI), Left Ventricular Stroke Work Index (LVSWI),...

Open the catalog to page 5
Ultraview SL™ Command Module - 6

Data Sheet Numeric update rate Every 3 seconds Pulse accuracy • No motion: ±3% SpO2 Accuracy (70% to 100%) of Masimo sensors LNCS DC-I, LNCS • No motion: ±2% DC-IP, LNCS TF-I**, • Low perfusiont: ±2% LNCS Adtx, LNCS Pdtx, LNCS Inf LNOP DC-I*, LNOP • No motion: ±2% DC-IP*, LNOP Adt*, • Low perfusiont: ±2% LNOP Pdt*, LNOP Inf-L* LNOP Neo*, LNOP • No motion: ±3.5% NeoPt*, LNOP • Low perfusiont: ±3.5% LNOP Neo-L • No motion: <3 kg ±3%, >40 kg ±2% * The accuracy specification under motion conditions is ±3%. Motion is defined as continuous rubbing and tapping motions at 2 to 4 Hz, at an amplitude...

Open the catalog to page 6
Ultraview SL™ Command Module - 7

Data Sheet Numeric update rate Every 3 seconds SpO2 accuracy (70% to 100%) of Nellcor sensors MAX-N*f, MAX-P*, MAX-I*, MAX-FAST OXI-AN, OXI-P/I MAX-R**, OxiCliq N ±3.5% (Neonate), D-YSE * The accuracy specification under motion conditions is ±3%. ** The accuracy specification has been determined between saturations of 80% and 100%. f The MAX-N and the OxiCliq N were tested on patients >40 kg. Neonatal accuracy When sensors are used on neonatal subjects as recommended, the specified accuracy range is increased by ±1 digit as compared to adult usage, to account for the theoretical effect on...

Open the catalog to page 7
Ultraview SL™ Command Module - 8

Data Sheet Numeric update rate Every 3 seconds (Height x Width x Depth) Controls Stop NIBP Volatile memory Data is preserved for at least 5 minutes but not longer than 10 minutes. Module ceases data collection when power is removed. Power source Powered directly from monitor (Xprezzon® (91393), Qube® (91390), or Qube Mini (91389)) For monitor electrical specifications, refer to Xprezzon, Qube, and Qube Mini Operations Manual (P/N 070-2112-xx) Protection against Module is electrically isolated from host device. electric shock Defibrillator protection Type CF, meets IEC 60601-2-27, AAMI EC-13...

Open the catalog to page 8
Ultraview SL™ Command Module - 9

Data Sheet ECG, respiration, NIBP, pulse oximetry, four invasive blood pressures, two temperatures, cardiac output NIBP, pulse oximetry, two temperatures Four invasive blood pressures, pulse oximetry (SpO2D), two temperatures Software options Arrhythmia* (F–Basic, G–Standard, or H–Advanced) Diagnostic 12-lead reports* (D–with interpretation or E–without interpretation) SpO2 technology (M–Masimo SET, N–Nellcor OxiMax, or U–Spacelabs) Respiration* (R) ST segment analysis* (S) Varitrend® oxycardiorespirogram* (V) * Not available with 91496-I and 91496-L configurations. For further ordering...

Open the catalog to page 9
Ultraview SL™ Command Module - 10

Data Sheet Applicable standard editions or document number/revision and description IEC 60601-2-34:2011 - Medical electrical equipment – Part 2-34: Particular requirements for the safety, including essential performance, of invasive blood pressure monitoring equipment EN 60601-2-34: 2014 - Medical electrical equipment - Part 2-34: Particular requirements for the basic safety and essential performance of invasive blood pressure monitoring equipment IEC 80601-2-30:2018 - Medical electrical equipment – Part 2-30: particular requirements for the basic safety and essential performance of...

Open the catalog to page 10