Overview: The document describes the Phoenix rotational atherectomy system, a medical device designed for treating peripheral vascular diseases. It combines features of existing atherectomy systems to offer a unique treatment option.
Specifications:
  • The system includes catheters of three diameters: 1.8 mm, 2.2 mm, and 2.4 mm, suitable for different vessel sizes and lesion types.
  • The 1.8 mm and 2.2 mm catheters are used for small vessels or highly stenosed lesions, while the 2.4 mm catheter is for larger vessels or eccentric lesions.
Effectiveness:
  • The EASE trial data supports the system's effectiveness in treating a range of tissue types, achieving a clinically driven target lesion revascularization (TLR) rate of less than 1%.
  • The system is effective for lesions both above and below the knee.
Ease of Use:
  • The system requires a single insertion, eliminating the need to remove and clean out debulked material.
  • It is battery-powered and does not require additional equipment or accessories.
Safety:
  • The front cutter design minimizes vessel trauma, with a perforation rate of 1.9% and dissection rate of 0.9%.
  • Distal embolization requiring intervention is less than 1%, with no use of distal protection.
Mechanism of Action:
  • The system operates on a cut, capture, and clear mechanism, using a front cutter, continuous capture blades, and an Archimedes screw to manage debulked tissue.
Clinical Case Studies:
  • Case studies demonstrate the system's ability to restore flow and increase lumen size without causing vessel injury.
Product Details:
  • Various catheter sizes and specifications are provided, including part numbers, catheter sizes, introducer sizes, working lengths, and guidewire diameters.
Design:
  • The system features a rotation knob, disposal outlet, handle on/off switch, and central guidewire port, with no external components required.
Manufacturer Information:
  • The device is manufactured by Koninklijke Philips N.V., with contact details provided for their locations in Belgium and the USA.
See more

Catalog excerpts

Phoenix atherectomy system Rotational atherectomy system-1

Phoenix Atherectomy catheter 2.2 mm deflecting The safe, simple and effective choice

 Open the catalog to page 1
Phoenix atherectomy system Rotational atherectomy system-2

The Phoenix rotational atherectomy system combines the benefits of existing atherectomy systems to deliver a unique atherectomy option. This will help you tailor your treatment approach for your patients. Safe Clinical concern Phoenix solution Vessel injury Front cutter clears tissue in a way that may help reduce potential trauma to the vessel Distal embolization requiring intervention Design of the Phoenix cutter head allows debulked material to be continuously captured <1% distal embolization 0% use of distal protection Effective • ASE trial data confirms Phoenix’s ability to effectively treat...

 Open the catalog to page 2
Phoenix atherectomy system Rotational atherectomy system-3

Phoenix has a cut, capture, and clear mechanism of action Cut Front cutter clears tissue in a way that may help reduce potential trauma to the vessel. Capture Blades are designed for continuous capture of debulked material. Archimedes screw clears debulked tissue.

 Open the catalog to page 3
Phoenix atherectomy system Rotational atherectomy system-4

Low profile system for distal lesion access2,4 Case performed by Dr. Christopher LeSar at the Vascular Institute of Chattanooga. Lesion identified in the dorsalis pedis.2 Low profile (5F), front cutting device allowed for direct access to very distal lesion location.2 Flow is restored post treatment with Phoenix. Phoenix created 67% luminal gain without vessel injury4 Case performed by Dr. Joseph Griffin at Baton Rouge General Hospital. IVUS pre-Phoenix: lesion identified in the popliteal artery. IVUS showed length of plaque and vessel diameter, confirmed Phoenix as optimal treatment choice and...

 Open the catalog to page 4
Phoenix atherectomy system Rotational atherectomy system-5

Phoenix atherectomy system Part number Catheter size Introducer size Working length Guidewire diameter A simple and easy to use system Central guidewire port Disposal outlet Handle on/off switch Phoenix catheter The Phoenix atherectomy system, shown with the catheter inserted into the handle drive unit. No external, off-table components are require

 Open the catalog to page 5
Phoenix atherectomy system Rotational atherectomy system-6

© 2020 Koninklijke Philips N.V. All rights reserved. Trademarks are the property of Koninklijke Philips N.V. or their respective owners. part nr.: D000123757/D www.philips.com/IGTdevices Philips Excelsiorlaan 41 1930 Zaventem, Belgium Volcano Corporation 2870 Kilgore Road Rancho Cordova, CA 95670 USA