X-Ray Tube Current: Pulsed Fluoro: Radiography: mA Accuracy: rise time is ideal for extremeties, specialized applications and vascular imaging. Benefit from Spellman’s 70 plus years of high voltage innovation with this MMB125PN3.5 Monoblock® X-Ray source specifically designed for the C-Arm OEM. Our advanced technology and design expertise in conjunction with our depth of manufacturing capabilities position Spellman as the wise choice for your Monoblock® requirements. Spellman’s Ultra-Fast MMB Series utilizes our unique technologies that increases the quality of the X-Ray beam and significantly reduces patient dose. Pulsed Fluoroscopy enhances imaging of dense and complex anatomy to further support dose management. With a rise time of <1ms, Spellman’s MMB Series is among the fastest in the industry. • Integrated HV Supply, Filament Supply, X-Ray Tube, Beam Port and Control Electronics • Compact & Lightweight • <1ms Rise Time is Ideal for Extremities • Specifically designed for the C-Arm OEM Input Power: Input Voltage: 190-264Vac, single phase, 50/60 Hz X-Ray Tube Voltage: Operational Range: kV Rise Time: Reproducibility: kV Ripple: kV Accuracy Fluoroscopy: kV Overshoot: 0.2mA to 6 mA (small focal spot) 0.5mA to 10 mA (small focal spot) 10mA to 40mA (large focal spot) ±10% Maximum Operating Conditions: Low Level Fluoro: 6 mA for 5 minutes X-Ray Characteristics: Focal Spot: Target Angle: Target Material: Beam Filter: Beam Geometry: X-Ray Leakage: Maximum Filament Current: High Level Fluoro: 10 mA for 2 minutes 0.5mm for small focus 1.6mm for large focus 16° Refer to line drawing from tank surface. Pulsed Fluoro: Pulse on time: Radiographic: Single shot large focal spot, Filament Inverter Switching Frequency: Anode Heat Content: Maximum Anode Heat Dissipation: Distance Between Focal Spot to X-Ray Output Window: Focal Spot Position: Maximum Anode Heat Dissipation: Average Power: Tank Heat Content: Max. Cooling Rate: 600W for 5 minutes No less than 675kHU 150W Refer to outline drawing, additionally it is marked on tank cover. X-Ray Tube Current Protection: Over Current (High mA): Trip point is set at 15% over maximum rated current, or at 15% over programmed output current value for longer than 50ms. Under Current (High mA): Trip point is set at 15% under programmed output current value for longer than 50ms. Over Current (Low mA): Trip point is set at 20% over maximum rated current, or at 20% over programmed output current value for longer than 50ms. Under Current (Low mA): Trip point is set at 20% under programmed output current value for longer than 50ms. Spellman I High Voltage Electronics Corporation Corporate Headquarters Hauppauge, New York USA +1 -631 -630-3000 FAX: +1 -631 -435-1620 e-mail: [email protected] www.spellmanhv.com Spellman High Voltage is an ISO 9001 and ISO 14001 Copyright © 2019 Spellman High Voltage Electronics Corp.
Open the catalog to page 1Spellman High Voltage is an ISO 9001 and ISO 14001 Copyright © 2019 Spellman High Voltage Electronics Corp. I High Voltage Electronics Corporation Corporate Headquarters Hauppauge, New York USA -631-630-3000 FAX: +1-631-435-1620 e-mail: [email protected]
Open the catalog to page 2SPELLMAN HIGH VOLTAGE ELECTRONICS CORPORATION PAGE 3 OF 3 DIMENSIONS: in.[mm] GENERATOR TANK FRONT VIEW 16° SIDE VIEW CONTROL UNIT FRONT VIEW REFER SERVICE TO QUALIFIED PERSONNEL INTERNAL PARTS MAY PRESENT A RISK OF ELECTRICAL SHOCK DURING SERVICING Corporate Headquarters Hauppauge, New York USA +1-631-630-3000 FAX: +1-631-435-1620 e-mail: [email protected] Spellman High Voltage is an ISO 9001 and ISO 14001 registered company Copyright © 2019 Spellman High Voltage Electronics Corp.
Open the catalog to page 34 Pages
4 Pages
2 Pages
2 Pages
1 Page
2 Pages
7 Pages
292 Pages
3 Pages
3 Pages
6 Pages
2 Pages
3 Pages
2 Pages
2 Pages
262 Pages
6 Pages