Brochure Cleanroom Technology - 2

PBS, FMS, and FBS series device families feature a modular design, meaning that the individual components are compatible with one another. Thus the laminar flow box FBS is made up of the protection box PBS plus the filter module FMS. For the user of a protection box PBS, this means that he can retrofit it to be a full laminar flow box by purchasing a filter module FMS. The FMS series laminar flow modules can be found on both the clean room cell and the clean room workbench. Laminar flow boxes Laminar flow module FMS series ,,SuSi“ Filter module without box Laminar flow module FMS...

Open the catalog to page 2
Brochure Cleanroom Technology - 3

Portable clean room technology ncreasing requirements for product quality and process reliability require a clean environment during manufacturing, treating and processing, and for storage. Clean room technology plays an increasingly important role in nearly all high-tech sectors. Laminar flow Examples: • Laser technology • Optics and optoelectronics • Microelectronics • anufacturing, processing and packaging M of food • ackaging of pharmaceutical products P • Chemical analysis The basic principle for the development of clean room technology was established in the USA in the Sixties, when...

Open the catalog to page 3
Brochure Cleanroom Technology - 4

High performance filter The SPETEC® laminar flow box FBS uses a type H 14 filter. It features a retention rate of 99.995%. This means that at a particle size of 0.12 pm (according to MPPS), the filter removes at least 99.995% of all particles. At a particle size of 0.3 pm, the retention rate is approx. 99.9995%. By using the H 14 filter, the SPETEC® laminar flow box FBS has an isolation factor of 10. This means that the air quality inside the laminar flow box is improved by a factor of at least 10 000 relative to the ambient air. Design The box is primarily made from anodized aluminium...

Open the catalog to page 4
Brochure Cleanroom Technology - 5

Laminar flow module The laminar flow module which comes equipped with a ceiling suspension can for example be used as a clean air shower or be integrated directed in a machine enclosure. Through the master/slave function, one control unit is able to control up 100 slave-modules (optional). Seri e£lA/Sl/ Super Silent Filter change The main filter is stored in a filter cartridge which is attached to the laminar flow module on its underside. This mechanism is especially advantageous when the modules are suspended from the ceiling or when these are mounted on clean room cells. As a result the...

Open the catalog to page 5
Brochure Cleanroom Technology - 6

Laminar flow module The Basic-module is a simpler, more affordable alternative to the laminar flow module of the “SuSi” series. The laminar flow module is offered in a simple, robust version. With an EC-motor with step-less speed regulation the air flow speed can be adjusted to the requirements. Through the Master/ Slave function one control unit is able to control up 100 Slave-modules (optional). The laminar flow module can be used as a separate filter unit or in combination with a clean room cell. Retrofitting into a laminar flow box is not possible. Dimensions: Name See page 26 for...

Open the catalog to page 6
Brochure Cleanroom Technology - 7

With the laminar flow box of the FBS series a portable clean room workspace is created which, depending on the model, can measure between 0.24 to 1.12 m2. It is used for the manufacture of products and for the storage of objects in clean room conditions. Ambient air is drawn in using EC fans and pushed through the filter. This generates an ISO class 5 laminar flow, i.e. the air streams down in parallel flow lines. Particles are picked up the flow of air and transported out of the box through the perforated floor. Technical Data The technical data have been tested and certified by...

Open the catalog to page 7
Brochure Cleanroom Technology - 8

As an alternative to the laminar flow box of the FBS series “SuSi”, this version is offered without a sliding door and perforated metal floor. As a result, work can be performed directly on the existing table A well thought out air circulation ensures that the air flow happens from the inside to the outside and no contamination through outside air occurs on the inside of the box. Dimensions: Name See page 27 for device dimensions.

Open the catalog to page 8
Brochure Cleanroom Technology - 9

PVC clean room strip curtain FBS-V series models consist of a laminar flow module FMS and a PVC clean room strip curtain. The PVC strip curtain which hangs down from the laminar flow module is adjusted so that its ends are flush with the device housing. Thanks to the laminar flow of air, there is no mixing of dirty ambient air. Dimensions: The laminar flow module is attached to the building's ceiling with ceiling hangers. The curtain prevents the entry of dirty air when people walk by or transport vehicles drive by. In general, this system is used to create localized clean room conditions...

Open the catalog to page 9
Brochure Cleanroom Technology - 10

The EFBS series laminar flow box also features an additional acid-resistant extraction system. The telescoping extraction arm, which can be positioned in three dimensions, can be adjusted precisely so that gases and vapours are extracted exactly where they are generated. There is practically no mixing of the vapours being extracted with the clean air flowing down from above, since the flow velocity at the tip of the extraction tube is higher than that of the clean air flow. The exhaust system has a maximum capacity of 1 cubic meter per minute and is continuously adjustable. Dimensions: Name...

Open the catalog to page 10
Brochure Cleanroom Technology - 11

The EFBS-V series devices are used where clean room conditions are required, but where these conditions are at the same time impaired by vapours, combustion gases, etc., e.g. AAS graphite tubes, ICP/MS, and laboratory benches used for chemical analysis. The extraction system has a maximum capacity of 1 cubic meter per minute and is continuously adjustable. The PVC strip curtain is adjusted so that its ends are flush with the device housing. Dimensions: Name Telescoping arm for extraction. Arm with three-dimensional position adjustment for connection to the acid-resistant extraction system....

Open the catalog to page 11
Brochure Cleanroom Technology - 12

Protection box PBS series The protection box PBS is used in the optics, analysis, and electronics industries to protect items against dust. However, it is not equipped with a filter module, but can be retrofit with one at any time to produce a laminar flow box. Portable tabletop exhaust hood EBS series The portable tabletop exhaust hood EBS is universally usable. It is corrosion and acid resistant. The maximum extraction capacity is 1 cubic meter per minute. Dimensions: Name The interior height is 805 mm The total height is 940 mm Height with the door open is 1441 mm The interior height is...