3SC General Specifications
2Pages

{{requestButtons}}

Catalog excerpts

3SC General Specifications - 1

GENERAL SPECIFICATIONS 3 BODY, MORGUE COOLER, SIDE OPENING EXTERIOR - FRONT: 20 GA. (.91mm) TYPE 304 POLISHED STAINLESS STEEL, #4 FINISH SIDES, BACK, TOP: .032" (.81mm) STUCCO EMBOSSED ALUMINUM INTERIOR - WALLS, CEILING: .032" (.81 mm) STUCCO EMBOSSED ALUMINUM DOOR: 20 GA. (.91mm) TYPE 304 STAINLESS STEEL, #4 FINISH FLOOR: 20GA (.91mm) GALVANIZED STEEL INSULATION - NOMINAL 4" (102mm) FOAMED IN PLACE POLYURETHANE INSULATION DOOR HEATERS - PERIMETER ANTI-SWEAT DEVICE, REPLACEABLE, HARDWARE - ADJUSTABLE, EDGEMOUNT TYPE, CHROME PLATED; EDGE MOUNTED KEYED LATCH; CARD HOLDER(S) GASKET - EXTRUDED VINYL, WELDED CORNERS, DART STYLE, REPLACEABLE CARRIAGE & FRAME - DOOR MOUNTED ROLLER FRAME, STAINLESS STEEL, ZINC PLATED BALL BEARING ROLLERS REMOVABLE TRAYS - QUANTITY 3, MT1 16 GA. (1.5mm) TYPE 304 POLISHED STAINLESS STEEL CONDENSING UNIT - DROP IN, SELF CONTAINED (TOP MOUNT), INDOOR REFRIGERATION SYSTEM; DESIGN LOAD OF 4,640 BTUH AT 95°F (35°C) AMBIENT TEMPERATURE AND 35°F (2°C) BOX TEMPERATURE; R-404A REFRIGERANT; OFF CYCLE DEFROST TIMER; 208-230 VOLTS/ 60 HERTZ/1 PHASE ELECTRICAL, 8.5 UNIT AMPS, PSC TYPE MOTORS ON CONDENSING UNIT WITH EC TYPE MOTORS ON EVAPORATOR; SYSTEM IS FACTORY-ASSEMBLED, EVACUATED, CHARGED, AND RUN TESTED DIGITAL TEMPERATURE READOUT SECTIONAL CONSTRUCTION SHIPPED DISASSEMBLED SHIPPING WEIGHT - 2,365 LB. (1073 KG.) APPROXIMATELY AVAILABLE OPTIONS: □ LIGHTING FIXTURE WITH PILOT SWITCH □ STAINLESS STEEL INTERIOR □ STAINLESS STEEL EXTERIOR □ STAINLESS STEEL TRIM ENCLOSURE PANELS □ ROLLER FRAME TRAY RAILS WITH ANTI-TILT FOR CSI/JEWETT BODY TRANSPORT SYSTEMS □ MODEL DTPM TEMPERATURE AND POWER MONITORING SYSTEM □ MODEL 7ER CIRCULAR SEVEN DAY CHART RECORDER □ CONTACT CSI/JEWETT FOR CUSTOM SPECIFICATIONS OR OPTIONS

Open the catalog to page 1
3SC General Specifications - 2

CONDENSING UNIT PACKAGE SYSTEM FRONT ELEVATION SIDE ELEVATION 1. (1) 115 VOLTS/60 HERTZ/1 PHASE, 15 AMP CIRCUIT FOR DOOR HEATERS, PROVIDE DISCONNECT SWITCH FOR EACH CIRCUIT, AND ALL JUNCTION BOX(ES), CONDUIT, AND FITTINGS AS REQUIRED BY STATE AND LOCAL REGULATIONS. WITHIN 5'-0" OF DESIGNATED AREA ON DRAWING. 2. (1) 208-230 VOLTS/ 60 HERTZ/1 PHASE, 15 AMP CIRCUIT FOR CONDENSING UNIT, PROVIDE DISCONNECT SWITCH FOR EACH CIRCUIT, AND ALL JUNCTION BOX(ES), CONDUIT, AND FITTINGS AS REQUIRED BY STATE AND LOCAL REGULATIONS. PROVIDE THE ABOVE REQUIREMENTS TO AN AREA ABOVE THE REFRIGERATOR AND WITHIN...

Open the catalog to page 2

All Spire Integrated Solutions catalogs and technical brochures

  1. CWC Series

    4 Pages

  2. Tesalys

    8 Pages

  3. Model DPEM

    2 Pages

  4. MC2-B-MT1

    2 Pages

  5. Model DPV

    2 Pages

  6. R1910-31L/R

    2 Pages

  7. SR1910-30

    2 Pages

  8. 6R2W SPECS

    2 Pages

  9. 4R2W Specs

    2 Pages

  10. 1R SUBMITTAL

    1 Pages