Catalog excerpts

GENERAL SPECIFICATIONS 3 BODY, MORGUE COOLER, END OPENING EXTERIOR - FRONT: 20 GA. (.91mm) TYPE 304 POLISHED STAINLESS STEEL, #4 FINISH SIDES, BACK, TOP: .032" (.81mm) STUCCO EMBOSSED ALUMINUM INTERIOR-WALLS, CEILING: .032" (.81mm) STUCCO EMBOSSED ALUMINUM DOOR: 20 GA. (.91mm) TYPE 304 STAINLESS STEEL, 2B FINISH FLOOR: 20 GA. (.91mm) TYPE 304 STAINLESS STEEL, 2B FINISH INSULATION - NOMINAL 4" (102mm) FOAMED IN PLACE POLYURETHANE INSULATION DOOR HEATERS - PERIMETER ANTI-SWEAT DEVICE, REPLACEABLE, HARDWARE - HINGES: EDGE MOUNT TYPE, CHROME PLATED, ADJUSTABLE; LATCHES: SAFEGUARD RADIAL LATCH, SURFACE MOUNT TYPE, CHROME PLATED, POSITIVE CATCH, KEYED, ROLLER STRIKE ASSEMBLY, AND INSIDE EMERGENCY RELEASE HANDLE; NAME PLATE HOLDERS: BRUSHED ALUMINUM, SIDE FEED GASKET - EXTRUDED VINYL, WELDED CORNERS, REPLACEABLE CARRIAGE & FRAME - 3 PIECE, TELESCOPING, GALVANIZED STEEL ZINC PLATED BALL BEARING ROLLERS REMOVABLE TRAY - QUANTITY 1, MT1 16 GA. (1.5mm) TYPE 304 POLISHED STAINLESS STEEL CART GUIDES -18 GA. (1.3mm) TYPE 304 STAINLESS STEEL, #4 FINISH CONDENSING UNIT -1/2 H.P. HERMETICALLY SEALED, AIR-COOLED EVAPORATING UNIT - BLOWER COIL, AUTOMATIC OFF-CYCLE DEFROST, DIGITAL TEMPERATURE CONTROLLER CAPACITY - (3) BODY WITH OPTIONAL MC2 CART SECTIONAL CONSTRUCTION SHIPPED DISASSEMBLED AVAILABLE OPTIONS: □ LIGHTING FIXTURE WITH PILOT SWITCH □ STAINLESS STEEL INTERIOR □ STAINLESS STEEL EXTERIOR □ STAINLESS STEEL TRIM ENCLOSURE PANELS □ OPPOSITE DOOR SWING □ ROLLER FRAME TRAY RAILS WITH ANTI-TILT FOR CSI/JEWETT BODY TRANSPORT SYSTEMS □ TWO-BODY MORGUE CART, MC2 WITH BODY TRAYS □ MODEL DTPM TEMPERATURE AND POWER MONITORING SYSTEM □ MODEL 7ER CIRCULAR SEVEN DAY CHART RECORDER □ OUTDOOR MOUNTED CONDENSING UNIT □ WATER COOLED CONDENSING UNIT □ CONTACT CSI/JEWETT FOR CUSTOM SPECIFICATIONS OR OPTIONS
Open the catalog to page 1
TELESCOPING CARRIAGE EVAPORATING UNIT MORGUE CART (OPTIONAL EXTRA) STEEL RAMP SIDE ELEVATION FRONT ELEVATION 1. (2) 115 VOLTS/60 HERTZ/1 PHASE, 15 AMP CIRCUIT FOR DOOR HEATERS, DIGITAL CONTROLLER AND EVAPORATOR, PROVIDE DISCONNECT SWITCH FOR EACH CIRCUIT, AND ALL JUNCTION BOX(ES), CONDUIT, AND FITTINGS AS REQUIRED BY STATE AND LOCAL REGULATIONS. WITHIN 5'-0" OF DESIGNATED AREA ON DRAWING. 2. (1) 208-230 VOLTS/ 60 HERTZ/1 PHASE, 20 AMP CIRCUIT FOR CONDENSING UNIT, PROVIDE DISCONNECT SWITCH FOR EACH CIRCUIT, AND ALL JUNCTION BOX(ES), CONDUIT, AND FITTINGS AS REQUIRED BY STATE AND LOCAL...
Open the catalog to page 2All Spire Integrated Solutions catalogs and technical brochures
-
CWC Series
4 Pages
-
Surgical Scrub Sinks
2 Pages
-
STERIPLUS™ 40
2 Pages
-
Tesalys
8 Pages
-
Cadaver Handling Solutions
16 Pages
-
Model DEM Dyna-Poise™
2 Pages
-
Model DPEM
2 Pages
-
Medicine Station
2 Pages
-
NSM5 Specifications
2 Pages
-
Model D Deluxe Autopsy Table
2 Pages
-
MC2-B-MT1
2 Pages
-
3SC General Specifications
2 Pages
-
2SC General Specifications
2 Pages
-
1SC General Specifications
2 Pages
-
Model DPV
2 Pages
-
DP AUTOPSY TABLE
2 Pages
-
R1910-31L/R
2 Pages
-
SR1910-30
2 Pages
-
REMOTE MORGUE
2 Pages
-
6R2W SPECS
2 Pages
-
4R2W Specs
2 Pages
-
3R1W SUBMITTAL
1 Pages
-
2R1W SUBMITTAL
1 Pages
-
1R SUBMITTAL
1 Pages