Catalog excerpts
GENERAL SPECIFICATIONS 4 BODY, MORGUE COOLER, END OPENING EXTERIOR - FRONT: 20 GA. (.91mm) TYPE 304 POLISHED STAINLESS STEEL, #4 FINISH SIDES, BACK, TOP: .032" (.81mm) STUCCO EMBOSSED ALUMINUM INTERIOR - WALLS, CEILING: .032" (.81mm) STUCCO EMBOSSED ALUMINUM DOOR: 20GA (.91mm) TYPE 304 STAINLESS STEEL, #4 FINISH FLOOR: 20GA (.91mm) GALVANIZED STEEL INSULATION - NOMINAL 4" (102mm) FOAMED IN PLACE POLYURETHANE INSULATION DOOR HEATER - PERIMETER ANTI-SWEAT DEVICE, REPLACEABLE, HARDWARE - EDGEMOUNT TYPE, CHROME PLATED, ADJUSTABLE; EDGE MOUNTED KEYED LATCH; CARD HOLDER(S) GASKET - EXTRUDED VINYL, WELDED CORNERS, DART STYLE, REPLACEABLE CARRIAGE & FRAME - 3 PIECE, TELESCOPING, GALVANIZED STEEL, ZINC PLATED BALL BEARING ROLLERS REMOVABLE TRAY - QUANTITY 4, MT1 16 GA. (1.5mm) TYPE 304 POLISHED STAINLESS STEEL CONDENSING UNIT - 3/4 H.P. HERMETICALLY SEALED, AIR COOLED EVAPORATING UNIT - BLOWER COIL, AUTOMATIC OFF-CYCLE DEFROST, DIGITAL TEMPERATURE CONTROLLER ELECTRICAL DATA - VOLTAGE 208-230 VOLTS/ 60 HERTZ/1 PHASE SECTIONAL CONSTRUCTION SHIPPED DISASSEMBLED SHIPPING WEIGHT - 2,975 LB. (1349 KG.) APPROXIMATELY AVAILABLE OPTIONS: □ LIGHTING FIXTURE WITH PILOT SWITCH □ STAINLESS STEEL INTERIOR □ STAINLESS STEEL EXTERIOR □ STAINLESS STEEL TRIM ENCLOSURE PANELS □ OPPOSITE DOOR SWING AVAILABLE □ ROLLER FRAME TRAY RAILS WITH ANTI-TILT FOR CSI/JEWETT BODY TRANSPORT SYSTEMS □ MODEL DTPM TEMPERATURE AND POWER MONITORING SYSTEM □ MODEL 7ER CIRCULAR SEVEN DAY CHART RECORDER □ OUTDOOR MOUNTED CONDENSING UNIT □ WATER COOLED CONDENSING UNIT □ REDUNDANT REFRIGERATION WITH AUTO-SWITCHOVER □ CONTACT CSI/JEWETT FOR CUSTOM SPECIFICATIONS OR OPTIONS THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CSV JEWETT. USE OF THIS INFORMATION WITHOUT THE EXPRESSED WRITTEN PERMISSION OF CSI/JEWETT IS STRICTLY PROHIBITED DRAWING IS FOR SALES REFERENCE ONLY 6910 WEST RIDGE ROAD
Open the catalog to page 1STATIONARY FRAME EVAPORATING UNIT SIDE ELEVATION FRONT ELEVATION 1. (2) 115 VOLTS/ 60 HERTZ/1 PHASE, 15 AMP CIRCUIT FOR DOOR HEATERS, DIGITAL CONTROLLER AND EVAPORATOR, PROVIDE DISCONNECT SWITCH FOR EACH CIRCUIT, AND ALL JUNCTION BOX(ES), CONDUIT, AND FITTINGS AS REQUIRED BY STATE AND LOCAL REGULATIONS. WITHIN 5'-0" OF DESIGNATED AREA ON DRAWING. 2. (1) 208-230 VOLTS/ 60 HERTZ/1 PHASE, 20 AMP CIRCUIT FOR CONDENSING UNIT, PROVIDE DISCONNECT SWITCH FOR EACH CIRCUIT, AND ALL JUNCTION BOX(ES), CONDUIT, AND FITTINGS AS REQUIRED BY STATE AND LOCAL REGULATIONS. PROVIDE THE ABOVE REQUIREMENTS TO AN...
Open the catalog to page 2All Spire Integrated Solutions catalogs and technical brochures
-
CWC Series
4 Pages
-
Surgical Scrub Sinks
2 Pages
-
STERIPLUS™ 40
2 Pages
-
Tesalys
8 Pages
-
Cadaver Handling Solutions
16 Pages
-
Model DEM Dyna-Poise™
2 Pages
-
Model DPEM
2 Pages
-
Medicine Station
2 Pages
-
NSM5 Specifications
2 Pages
-
Model D Deluxe Autopsy Table
2 Pages
-
MC2-B-MT1
2 Pages
-
3SC General Specifications
2 Pages
-
2SC General Specifications
2 Pages
-
1SC General Specifications
2 Pages
-
3SP1W General Specifications
2 Pages
-
Model DPV
2 Pages
-
DP AUTOPSY TABLE
2 Pages
-
R1910-31L/R
2 Pages
-
SR1910-30
2 Pages
-
REMOTE MORGUE
2 Pages
-
6R2W SPECS
2 Pages
-
3R1W SUBMITTAL
1 Pages
-
2R1W SUBMITTAL
1 Pages
-
1R SUBMITTAL
1 Pages