6R2W SPECS
1 / 2Pages

Catalog excerpts

6R2W SPECS - 1

GENERAL SPECIFICATIONS 6 BODY, MORGUE COOLER, END OPENING EXTERIOR - FRONT: 20 GA. (.91mm) TYPE 304 POLISHED STAINLESS STEEL, #4 FINISH SIDES, BACK, TOP: .032" (.81mm) STUCCO EMBOSSED ALUMINUM INTERIOR - WALLS, CEILING: .032" (.81mm) STUCCO EMBOSSED ALUMINUM DOOR: 20GA (.91mm) TYPE 304 STAINLESS STEEL, #4 FINISH FLOOR: 20GA (.91mm) GALVANIZED STEEL INSULATION - NOMINAL 4" (102mm) FOAMED IN PLACE POLYURETHANE INSULATION DOOR HEATER - PERIMETER ANTI-SWEAT DEVICE, REPLACEABLE, HARDWARE - EDGEMOUNT TYPE, CHROME PLATED, ADJUSTABLE; EDGE MOUNTED KEYED LATCH; CARD HOLDER(S) GASKET - EXTRUDED VINYL, WELDED CORNERS, DART STYLE, REPLACEABLE CARRIAGE & FRAME - 3 PIECE, TELESCOPING, GALVANIZED STEEL, ZINC PLATED BALL BEARING ROLLERS REMOVABLE TRAY - QUANTITY 6, MT1 16 GA. (1.5mm) TYPE 304 POLISHED STAINLESS STEEL CONDENSING UNIT - 3/4 H.P. HERMETICALLY SEALED, AIR COOLED EVAPORATING UNIT - BLOWER COIL, AUTOMATIC OFF-CYCLE DEFROST, DIGITAL TEMPERATURE CONTROLLER SECTIONAL CONSTRUCTION SHIPPED DISASSEMBLED SHIPPING WEIGHT - 3,655 LB. (1658 KG.) APPROXIMATELY AVAILABLE OPTIONS: □ LIGHTING FIXTURE WITH PILOT SWITCH □ STAINLESS STEEL INTERIOR □ STAINLESS STEEL EXTERIOR □ STAINLESS STEEL TRIM ENCLOSURE PANELS □ OPPOSITE DOOR SWING AVAILABLE □ ROLLER FRAME TRAY RAILS WITH ANTI-TILT FOR CSI/JEWETT BODY TRANSPORT SYSTEMS □ SINGLE FULL HEIGHT DOORS □ MODEL DTPM TEMPERATURE AND POWER MONITORING SYSTEM □ MODEL 7ER CIRCULAR SEVEN DAY CHART RECORDER □ OUTDOOR MOUNTED CONDENSING UNIT □ WATER COOLED CONDENSING UNIT □ REDUNDANT REFRIGERATION WITH AUTO-SWITCHOVER □ CONTACT CSI/JEWETT FOR CUSTOM SPECIFICATIONS OR OPTIONS

Open the catalog to page 1
6R2W SPECS - 2

/ELEC. CONNECTION TELESCOPING CARRIAGE STATIONARY FRAME EVAPORATING UNIT REFR. CONNECTION CONDENSING UNIT SIDE ELEVATION FRONT ELEVATION 1. (2) 115 VOLTS/ 60 HERTZ/1 PHASE, 15 AMP CIRCUIT FOR DOOR HEATERS, DIGITAL CONTROLLER AND EVAPORATOR, PROVIDE DISCONNECT SWITCH FOR EACH CIRCUIT, AND ALL JUNCTION BOX(ES), CONDUIT, AND FITTINGS AS REQUIRED BY STATE AND LOCAL REGULATIONS. WITHIN S-CP OF DESIGNATED AREA ON DRAWING. 2. (1) 208-230 VOLTS/ 60 HERTZ/1 PHASE, 15 AMP CIRCUIT FOR CONDENSING UNIT, PROVIDE DISCONNECT SWITCH FOR EACH CIRCUIT, AND ALL JUNCTION BOX(ES), CONDUIT, AND FITTINGS AS...

Open the catalog to page 2

All Spire Integrated Solutions catalogs and technical brochures

  1. CWC Series

    4 Pages

  2. Tesalys

    8 Pages

  3. Model DPEM

    2 Pages

  4. MC2-B-MT1

    2 Pages

  5. Model DPV

    2 Pages

  6. R1910-31L/R

    2 Pages

  7. SR1910-30

    2 Pages

  8. 4R2W Specs

    2 Pages

  9. 1R SUBMITTAL

    1 Pages