1080 - 2

Easily Analyze Difficult to Oxidize Samples Total organic carbon (TOC) measurement is a well-established technique that provides valuable information about water quality for process control and regulatory compliance. Though high-temperature combustion TOC has been shown to be very effective for the analysis of samples that are of a high molecular weight or contain substantial amounts of salt or difficult-tooxidize organics (e.g, humic acid), these types of samples are problematic for combustion TOC analyzers. They can clog the instrument, cause catalyst poisoning, and shorten the injector...

Open the catalog to page 2
1080 - 3

Designed for Performance & Simplicity Engineered for Performance High-temperature catalytic combustion oxidizes and converts the organic compounds present in aqueous samples to CO2 for measurement by a solid-state, non-dispersive infrared (SS-NDIR) detector. Patent-pending technologies protect the catalyst, increase reliability, reduce maintenance and operating costs, and extend the life of the instrument. Automation The 1080 TOC also offers automatic sample acifidification and sparging. The automatic dilution function reduces sample salinity, acidity, and alkalinity, significantly...

Open the catalog to page 3
1080 - 4

Superior Technology for Better Results 1080 High-Temperature Combustion TOC Analyzer Our experienced team of chemists and engineers set out to design an instrument that would make TOC analysis easy and affordable. The new technology of the 1080 Combustion TOC Analyzer inspires confidence in results, lowers operating costs, and ensures reliability. Ease of Operation The 1080 TOC Analyzer was designed with the operator in mind. It has been carefully engineered to provide an intuitive workflow experience. You can view the instrument status at a glance from anywhere in the lab with the TruColour™...

Open the catalog to page 4
1080 - 5

Superior sample flexibility Large or small, sample size is no with no loss in precision longer a problem! The new pulsed time injection® more accurately injects sample volumes for greater flexibility over a large range. Reduce instrument downtime OI Analytical's Smart Slide Injector® significantly extends the life of the injector, reducing operating costs. High sensitivity for difficult samples A novel stop-flow process converts the sample to steam prior to detection for improved low-level sensitivity. Our specially designed Catalyst Guard® combustion reactor comes standard with the 1080...

Open the catalog to page 5
1080 - 6

Intuitive Software & Optional Accessories TOC View Software Interface The TOC View Software provides fully automated data collection, analysis, reporting, and storage in a LIMS environment using a logical, easy-to-follow layout. Methods Menu Create methods for the analysis of a wide variety of samples for optimal results. Sequences Menu Easy to setup and priority samples can be added on the fly. Maintenance Menu Perform routine checks and tests at the touch of a button. Main (Monitor) Menu Quickly and easily monitor sequence status and other important instrument parameters at a glance....

Open the catalog to page 6
1080 - 7

Sea Water Application Results * -11 TOO- Measurement Method: NPOCi with sample acidification Measurement Results: 10-ppm C in 3.5% NaCI matrix Environmental Sample Results Optional Accessories The 1080 TOC can be equipment with a number of instrument options and automation accessories to improve sample throughput and productivity. 88-position Rotary Autosampler Model 1088 Rotary Autosampler is positioned below the TOC analyzer for convenient installation. • Automated Dilution • In-Situ Stirring • 88 (40 mL) sample vials Total Bound Nitrogen (TNb) The optional TNb Nitrogen detector allows...

Open the catalog to page 7
1080 - 8

O'l-Analytical SS a xylem brand 151 Graham Road PO Box 9010 College Station, Texas 77842-9010 (979) 690-1711 (800) 653-1711 USA/Canada FAX (979) 690-0440 www.oico.com E-mail: oi-info@xyleminc.com Microsoft® and Windows are registered trademarks of Microsoft Corporation. Teflon® is a registered trademark of E.I. DuPont de Nemours, Inc. OI Analytical® is a registered trademark of Xylem, Inc. *U.S. & World Patents Pending

Open the catalog to page 8