IMRT - 1

• VERSATILE COMPREHENSIVE Gain confidence in the accuracy of your treatment plans and help improve patient outcomes • VERIFY PATIENT IMRT TREATMENT PLANS The anthropomorphic design of the IMRT Dose Verification HELPS COMPLETE • FAST AND VERSATILE SET-UP AND EASILY DOSE VERIFICATION QUICKLY Phantom mimics human anatomy which assists in set The IMRT Dose Verification Phantom can combine up and treatment for patient dose verification. It is ideal absolute, relative and point dose measurements, with for prostate and head and neck regions, as well as for up to 16 chamber positions, 5 film positions and up to commissioning respiratory gated protocols because the 9 diodes or TLDs. By using a fast coronal film orientation, accuracy of prescribed dose is evaluated and confirmed in the IMRT Dose Verification Phantom captures the dose simulated patient conditions. The IMRT Dose Verification contribution of all fields and segments, as well as showing Phantom is available in Acrylic REF 91230 or Virtual Water™ hot and cold spots on the film, for comparison to the treatment plan. The IMRT Dose Verification Phantom effectively evaluates head and neck junction issues SSURE ACCURACY IN RESPIRATORY GATING WITH A THE OPTIONAL RESPIRATORY GATING PLATFORM of upper neck and half beam superclav fields. It also The unique Respiratory Gating Platform REF 72249 lung equivalents. simulates breathing providing the means to create a comprehensive program for commissioning, training, quality assurance, and dose verification of gated IMRT treatments. incorporates inhomogeneity structures with bone and

Open the catalog to page 1
IMRT - 2

Optional Accessories Solid Acrylic (Virtual Water™) Ion Chamber Slab has six cavities for thimble ion chamber measurement. The diameter of each cavity is 19 mm. Solid acrylic (Virtual Water) plugs are included to fill the cavities for simulated patient thickness. One solid acrylic (Virtual Water™) plug is drilled for the ion chamber of choice. A bone equivalent plug is included for bone simulation of heterogeneity measurements. Solid Acrylic (Virtual Water™) Blank Slab is a solid slab to provide simulated patient build-up material. Four 2 mm steel balls are imbedded in the slab as reference...

Open the catalog to page 2

All Standard Imaging catalogs and technical brochures

  1. SuperMAX

    8 Pages

  2. MIMI

    2 Pages

  3. Lucy 3D QA

    12 Pages

  4. DoseView 1D

    4 Pages

  5. DoseView 3D

    12 Pages