IMSure Brochure - 1

• FAST, precise Software for accurate and independent verification of monitor units, dose, and overall validity of standard, IMRT, rotational or brachytherapy plans – no film, no phantoms, no linac time required

Open the catalog to page 1
IMSure Brochure - 2

In Fast, Accurate Plan Verification The Model Makes the Difference In traditional radiation therapy, ‘hand-calculation’ has become an accepted practice for verifying beams and doses. Though similar, the process for verifying IMRT or rotational (RapidArc™ or VMAT) delivery is much more complex. Dynamic MLC delivery creates hundreds of small fields that are extremely difficult to ‘hand-calculate’. Additionally, IMRT that involves film, phantoms or other measurement devices can often take up to two hours per patient to perform. IMSure QA Software uses algorithms, including the patented...

Open the catalog to page 2
IMSure Brochure - 3

• The 3-Source Model In this illustration of a linac head, the red beam represents the primary photon source and the white lines show radiation scattered by the main collimator and the flattening filter. Much of this scattered radiation stays in the head but some reaches the patient through the jaws and the multi-leaf collimator. This scattered radiation can contribute up to 12% of the dose the patient receives. IMSure QA is the only dose calculation software that uses the patented 3-Source Algorithm to accurately calculate the contribution to dose from all three of these sources.

Open the catalog to page 3
IMSure Brochure - 4

Easy Monitor Unit Verification on-IMRT plans for both photon and electron beams are easy to verify in IMSure QA. The information you need to verify your plan is shown on a single screen. Imported information is automatically filled in or you can enter the information for each beam manually to create simple plans. Support for open beams, beams with blocks and wedged beams including the Varian Enhanced Dynamic Wedge, Elekta Omni Wedge and Siemens Virtual wedge is included. hand calculations ^ Cfficm& I I Ldpif f Colon | PBIHTH Onjfi [cmUPiKBtl ISC]_ Advanced Features I MSure QA Software...

Open the catalog to page 4
IMSure Brochure - 5

mporting the structure set along with your plan allows for better visualization of your plan data. Utilize contours to draw blocks for tissue sparing or to account for missing tissue (flash). .decimal Compensator Support tilizing a full convolution algorithm, IMSure models the scatter, beam hardening effects and field-size dependencies to calculate a true compensator factor for even the most complex .decimal filters. Cyberknife Plan Verification Module he Cyberknife module quickly and easily validates monitor units and dose for Raytrace and Monte Carlo plans created on the MultiPlan®...

Open the catalog to page 5
IMSure Brochure - 6

Fast IMRT, RapidArc™ and VMAT Dose Verification he IMSure QA Software 3-Source Model delivers an accurate secondary check of your treatment plan quickly and easily. Only two steps, and less than a minute, are needed to perform a dose calculation with IMSure QA. Click the ‘Import Plan’ button, and choose your patient treatment plan. Then click the ‘Calculate Dose’ button, and you are ready to analyze the results. The patented Stanford University 3-Source Model considers the dose from the primary photon source, the primary collimator scatter, and the flattening filter scatter, resulting in...

Open the catalog to page 6
IMSure Brochure - 7

RapidArc Plan Calculation Simplified The ARC QA Tool helps limit the complex calculations associated with RapidArc plans by splitting DICOM-RT plan files into user-defined sub-arcs. The sub-arcs allow for accurate SSD and effective depth values that provide better agreement than full arc calculations. • Full Plan Evaluation for RapidArc Reset gantry, collimator and couch angles to 0, mimicking a multi-field IMRT plan, allowing for the creation of fluence maps for each sub-beam. IMSure then conducts a full evaluation of the plan, including a fluence comparison. Split Plans for Measured QA...

Open the catalog to page 7
IMSure Brochure - 8

Comprehensive Report Formats rint comprehensive reports of your calculation results for attachment to the patient record or export to a PDF file for use with electronic record keeping. Visit www.standardimaging.com or call 800-261-4446 for more details. I M S u r e Q A S o f t w a r e ( R EF 9 1 3 2 6 ) sp e c i f i c a ti o n s operating system Windows® XP Windows Vista® Windows® 7 Hard Drive Screen resolution Processor Intel ® or AMD®, 600 MHz or greater CD–ROM Drive product standards Windows and Windows Vista are registered trademarks of Microsoft Corporation. Specifications subject to...

Open the catalog to page 8
IMSure Brochure - 9

IMSure QA™ Software BRACHYTHERAPY Fast, Accurate Brachytherapy Plan Checks The Brachytherapy Module, available as an add-on component to IMSure version 3.3, imports DICOM-RT plan files from treatment planning systems and utilizes the TG-43 formulism for dose calculations (Comparison to plan is in percentage difference). View calculation reference points and sources, including catheters and dwell positions, in three dimensions with keyboard shortcuts for viewing orthogonal, sagittal, transverse and coronal planes. In-depth Analysis of Each Dwell Position Choose the calculation point and...

Open the catalog to page 9
IMSure Brochure - 10

www.standardimaging.com 800-261-4446 . ph 608-831-0025 . fax 608-831-2202 3120 Deming Way Middleton WI 53562-2532 USA © 2011 Standard Imaging, Inc.