Stereotactic Dose Verification Phantom
8Pages

{{requestButtons}}

Catalog excerpts

Stereotactic Dose Verification Phantom - 1

• VERSATILE Stereotactic QA For fast and accurate commissioning of Accuray CyberKnife® treatment systems and patient specific dose verification plans Stereotactic Dose Verification Phantom

Open the catalog to page 1
Stereotactic Dose Verification Phantom - 2

Stereotactic Radiosurgery QA The Stereotactic Dose Verification Phantom provides dose measurements for commissioning treatment systems, such as Accuray CyberKnife®, and specific plan dose verification. With just one phantom, use film, ion chambers and the unique SRS Dosimetric QA Slab to perform fast and accurate system evaluation. Included ion chamber plugs Model A16 Exradin Microchamber Model A19 Exradin Classic Farmer-type Chamber Precise orientation and positioning – Ideal for Accuray CyberKnife®

Open the catalog to page 2
Stereotactic Dose Verification Phantom - 3

Convenient Design The standard phantom is 20 x 20 x 10 cm in size, comprised of two 4 cm top and bottom build-up slabs, and two interchangeable 2 cm test inserts in the center. Optional inserts include the SRS Dosimetric QA Slab and SDVP Heterogeneity insert. Rigid alignment posts ensure phantom configurations are precisely repositioned, and thumb or flat-head screws secure the phantom together for repeatable results. The Stereotactic Dose Verification Phantom is constructed of Blue Water material and additional slabs are available in many thicknesses for increased build-up. gold markers...

Open the catalog to page 3
Stereotactic Dose Verification Phantom - 4

Customizable Configurations Validate dose conformity, Monte Carlo algorithms and small field measurements with the Stereotactic Dose Verification Phantom inserts. SDVP with Srs Dosimetric Qa Insert SDVP with SDVP Heterogeneity Insert Srs Dosimetric Qa Insert [optional] SDVP Heterogeneity Insert [optional] For rigorous testing and evaluation of imaging, treatment planning, and dose conformity. Verify your treatment planning system’s Monte Carlo dose calculation within 0.5%. The SRS Dosimetric QA Insert provides complex geometric targets to evaluate the imaging avoidance and inclusion...

Open the catalog to page 4
Stereotactic Dose Verification Phantom - 5

SDVP with Film Dosimetry Insert SDVP with Ion Chamber Insert Film Dosimetry Insert [included] Ion Chamber Insert [included] Five water equivalent Blue Water slabs allow film to be positioned 2 mm apart for dose profile measurements of very small SRS targets. A cavity in each slab positions a 2.5 x 2.5 inch film in the exact center. The 2 cm Blue Water Ion Chamber Insert has a cavity drilled to accommodate inter-changeable ion chamber plugs, allowing one slab to accommodate several plugs drilled for different ion chambers. The ion chamber plug positions the detector in the exact center of...

Open the catalog to page 5
Stereotactic Dose Verification Phantom - 6

Blue Water Construction Blue Water Construction Build-up Slabs • Two 4.0 cm thick Blue Water slabs positioned above and below the film, chamber or SRS QA Dosimetric Slab provide adequate build-up • White fiducial lines are located on the X, Y, Z coordinates of the phantom • Two 4.0 cm thick Blue Water slabs positioned above and below the film, chamber or SRS QA Dosimetric Slab provide adequate build-up • Alignment posts provide a clamping mechanism to prevent the phantom slabs from moving during use Build-up Slabs 6 MV X-Rays Water vs Blue Water 1.020 • White fiducial lines are located on...

Open the catalog to page 6
Stereotactic Dose Verification Phantom - 7

Related Products Supermax Electrometer & Exradin W1 Scintillator The SuperMAX electrometer paired with the Exradin W1 makes dose verification with the CyberKnife easier, simplifying and streamlining the process via integrated design and a straightforward user interface. SuperMAX • The premier two-channel, reference-grade electrometer on the market • Two independent measurement channels • Built-in detector library W1 Scintillator • Near water equivalence • Linear dose response • Dose rate independence Pipspro Software PIPSpro 5.1 is your CyberKnife image analysis software. Version 5.1 of...

Open the catalog to page 7
Stereotactic Dose Verification Phantom - 8

www.standardimaging.com 800-261-4446 . ph 608-831-0025 . fax 608-831-2202 3120 Deming Way Middleton WI 53562-1461 USA © 2014 Standard Imaging, Inc.

Open the catalog to page 8