Stening® Devices’ Presentation
30Pages

{{requestButtons}}

Catalog excerpts

Stening® Devices’ Presentation - 1

Devices’ Presentation

Open the catalog to page 1
Stening® Devices’ Presentation - 2

Table of Contents o Bronchology • Stents • Special Prostheses o Laryngology and Tracheostomy • T-Tubes • Cannulas •

Open the catalog to page 2
Stening® Devices’ Presentation - 4

Bronchology Stents

Open the catalog to page 4
Stening® Devices’ Presentation - 5

Stening® Tracheal Stent (ST) The Stening® Tracheal stent is the classical and straight stent for tracheal affections. It has a tubular structure, with flat surface anchoring studs on its outer wall to prevent stent migration. It is used in: • Primary or secondary tracheal neoplasm • Tracheoesophageal fistula • Tracheal rupture • After laser resection, cryotherapy or electrocautery, to maintain the airway opened. • Extrinsic compression or compromise of the submucosa • Post intubation stenosis • Post-traumatic stenosis • Post infectious stenosis (endobronchial tuberculosis, histoplasmosis...

Open the catalog to page 5
Stening® Devices’ Presentation - 6

Stening® Bronchial Stent (ST) Stening® Bronchial stent follows the Stening® Tracheal stent general design, with some changes on its walls’ thickness and its dimensions. It is introduced in a wide range of diameters and lengths, sharing a lot of indications described for the tracheal version. It is used in: • Bronchial neoplasms • Neoplasms that invade the tracheal carina or its slopes • Imminent atelectasis • After laser resection, cryotherapy or electrocautery, to maintain the airway opened • Bronchial stenosis • Post infectious stenosis (endobronchial tuberculosis, histoplasmosis...

Open the catalog to page 6
Stening® Devices’ Presentation - 7

Tracheal Stenosis Stent (SET) It is a tracheal stent of easy implant and removal. It is especially suitable for the benign stenosis treatment. With a 14, 15 and 16 mm diameter on its edges and a 12, 13 and 14 mm diameter respectively on its central portion, constitutes a profile that increase the difficulty of its spontaneous displacement after being introduced. The stents for tracheal stenosis (SET) have a 5 mm longer version: “L”. These variants are how Stening® responds to the needs on treatment for special clinical situations. It is used in: • Simple tracheal stenosis • Complex and long...

Open the catalog to page 7
Stening® Devices’ Presentation - 8

Stening® “Y” Stent (SY) Flexible tracheo-carino-bronchial prosthesis for supporting tracheal bifurcation and carinal angle, able to maintain ventilation through the main bronchi in very advanced obstructive conditions. It is used in: • Tracheal neoplasms • Long tracheobronchial neoplasm, with or without a compromise for the carina and/or its slopes • Neoplasms that affect both sources • Oesophageal carcinoma with an airway invasion • Tracheoesophageal or tracheocutaneous fistula • After laser resection, cryotherapy or electrocautery, to maintain the airway opened • Extrinsic compression or...

Open the catalog to page 8
Stening® Devices’ Presentation - 9

Bronchology Special Prostheses

Open the catalog to page 9
Stening® Devices’ Presentation - 10

Stening® Class Stent (CLASS) The Stening® Class Stent is a device designed to maintain the clearance of the airway in sufficient conditions for ventilation. It has a conical elastic tubular structure, with non-slip spurs arranged in several rows and distributed symmetrically along its surface. Special features: Gradual resistance: To accompany the functionality of the bronchus and its physiology, the strength of its wall is progressively reduced distally at a rate of 3% per each centimeter of the length of the stent. Increase in fixing capacity: Although the increase in the fixing capacity...

Open the catalog to page 10
Stening® Devices’ Presentation - 11

Stening® Class LSD Stent (CLASS LSD) The Stening® Class LSD Stent is a device designed to maintain the clearance of the airway in sufficient conditions for ventilation. It has a side hole that allows ventilation of the right upper lobe. It has a conical elastic tubular structure, with non-slip spurs arranged in several rows and distributed symmetrically along its surface. Special features: Gradual resistance: To accompany the functionality of the bronchus and its physiology, the strength of its wall is progressively reduced distally at a rate of 3% per each centimeter of the length of the...

Open the catalog to page 11
Stening® Devices’ Presentation - 12

Stening® Roll (Roll) The Stening® Roll is the Stening response to the clinical need on carrying out diseases treatments for small bronchi, but that are still capable of providing ventilation to its distal segments. This can be seen in the neoplastic infiltrations in the lower lobar bronchi both right and left ones. In this way, the interventionist and therapeutic bronchoscopy extends its scopes and Stening accompanies it with the development of devices that can be applicable in minor bronchi. As well as in peripheral ones and those with low resistance on their thin walls. These force the...

Open the catalog to page 12
Stening® Devices’ Presentation - 13

Stening® Bronchial LSD Stent (ST LSD) The LSD from Stening®, with a lateral hole, is useful for diseases in the main right bronchus or the intermediate one when you want to preserve the ventilation of the upper lobe through the lateral hole of the stent. The hole must be orientated to this lobar. It is used in: • Neoplasms in the main right bronchus or intermediate one that do not affect the upper lobar • Extrinsic compression under equal conditi

Open the catalog to page 13
Stening® Devices’ Presentation - 14

Stening® Solid Stent MS10 (MS10) Stening® Solid Stent made out of silicone and intended for bronchial occlusion in the treatment of different bronchopleural pulmonary affections such as the bronchopleural fistula and persistent air loss in pneumothorax cases that cannot be treated with conventional surgery. It is radiopaque (white or pale yellow). Presentation: the Stening® Solid Stent, MS10, is supplied in a container that has two units of 5mm of greater diameter, four of 6mm, two of 7mm and two of 8mm. It is used in: • Bronchopleural fistula • Suture failure in a stump after lobar...

Open the catalog to page 14
Stening® Devices’ Presentation - 15

Stening® Solid Stent MS03 (MS03) Stening® Solid Stent made out of silicone and intended for bronchial occlusion in the treatment of different bronchopleural pulmonary affections such as the bronchopleural fistula and persistent air loss in pneumothorax cases that cannot be treated with conventional surgery. The Solid Stent is presented in three different sizes: MS810, MS911 and MS1012. It is radiopaque (white or pale yellow). It is used in: • Bronchopleural fistula. • Suture failure in a stump after lobar pulmonary resection. • Occluded bronchial treat

Open the catalog to page 15

All Stening catalogs and technical brochures

  1. stening

    50 Pages