1. Catalogs
  2. STERIS - CANTEL
  3. ADVANTAGE PLUS® Pass-Thru Endoscope
video corpo

ADVANTAGE PLUS® Pass-Thru Endoscope

ADVANTAGE PLUS® Pass-Thru Endoscope

ADVANTAGE PLUS® Pass-Thru Endoscope

Product catalog summary
Overview
The MEDIVATORS® ADVANTAGE PLUS® Pass-Thru Endoscope Reprocessing System is designed for efficient and high-standard endoscope reprocessing. It integrates advanced infection prevention and control measures with ergonomic and hands-free operation, making it suitable for high-volume facilities.

Key Features
  • Pass-Through Design: Facilitates separation of clean and contaminated areas, reducing contamination risk.
  • Compatibility: Works with all flexible endoscopes and supports asynchronous operation for increased availability.
  • Disinfection: Utilizes peracetic acid for high-level disinfection, ensuring fast and effective endoscope availability.
  • Data Management: Equipped with a barcode reader and PC-based system for accurate data entry and cycle monitoring.
  • Modular Design: Allows for future growth and customization to fit facility needs.

Endoscope Reprocessing
  • Cycle Time: Approximately 23 minutes per endoscope.
  • Cleaning Cycle: Features continuous channel monitoring and blockage detection for thorough cleaning.
  • Documentation: ENDORA™ Tracking System ensures all reprocessing steps are completed properly.

ENDODRY™ Storage & Drying System
  • Drying Process: Uses HEPA filtered air to eliminate moisture and reduce bacterial growth.
  • Protection: Rigid cassette system prevents damage and contamination during storage.
  • Data Management: Integrated sensors and interfaces provide detailed drying status and traceability.

Specifications
  • ADVANTAGE PLUS Pass-Thru Reprocessor: Dimensions: 2000mm (h) x 1316mm (w) x 792mm (d); Power: 230 V, 1800 Watts; Water Supply: 5L/min at 2-6 bar.
  • ENDODRY Cabinet: Dimensions: 1900mm (h) x 669mm (w) x 542mm (d); Power: 100-240 VAC; Holds 8 endoscopes.

Contact Information
Medivators Inc. and its global offices provide support and distribution for the ADVANTAGE PLUS® system.
See more

Catalog excerpts

ADVANTAGE PLUS® Pass-Thru Endoscope-1

ADVANTAGE PLUS® Pass-Thru Endoscope Reprocessing System MEDIVATORS® ADVANTAGE PLUS® Pa Endoscope Reproce MEDIVATORS® ADVANTAGE PLUS® Pas Endoscope Reprocess Advanced pass-through design ® MEDIVATORS® ADVANTAGE PLUS Pas Fast Endoscope Reproces and efficient turnover Hands-free operation Built on proven ADVANTAGE PLUS technology ADVANTAGE PLUS® Pass-Thru Endoscope Reprocessing System MEDIVATORS® ADVANTAGE PLUS® P

 Open the catalog to page 1
ADVANTAGE PLUS® Pass-Thru Endoscope-2

FAST AND FLEXIBLE – THE FUTURE OF ENDOSCOPE REPROCESSING Medivators offers a unique reprocessing system that fully integrates the highest standards in infection prevention and control with protection and security for flexible endoscope management. The ADVANTAGE PLUS® Pass-Thru Reprocessor, built upon the proven ADVANTAGE PLUS Reprocessor platform, answers highest requirements of endoscopy units and “Centers of Excellence” worldwide. With its pass-thru capability and integrated smart technology for fast, asynchronous reprocessing utilizing touch-free operation and reduced scope handling, it allows...

 Open the catalog to page 2
ADVANTAGE PLUS® Pass-Thru Endoscope-3

HANDS-FREE & ERGONOMIC PASS-THROUGH DESIGN O Built on the highly successful ADVANTAGE PLUS Reprocessor platform O 100% serviceable from the dirty side O Provides ease of use & lessens risk of contamination REPROCESSES A VARIETY OF ENDOSCOPES O Compatible with all flexible endoscopes O Asynchronous operation, maximizing scope availability PERACETIC ACID HIGH-LEVEL DISINFECTANT O Proven endoscope compatibility O Fast endoscope availability O 5-min at 20°C disinfection O Reduced worker exposure O Environmentally responsible O Compatible with RAPICIDE® PA and ADASPOR® Single Shot PA EXTENSIVE CYCLE...

 Open the catalog to page 3
ADVANTAGE PLUS® Pass-Thru Endoscope-4

NEW DESIGN, EASIER USABILITY – THE CASSETTE SYSTEM D esigned specifically for use with MEDIVATORS® ADVANTAGE PLUS® Pass-Thru Reprocessor and ENDODRY™ Storage & Drying System: Cassettes now made from biocompatible polypropylene: even lighter and easier to use Hookup cassette is transported from reprocessor and inserts directly into shelf ventilation port – one simple connection; maximizes efficiency and saves time HIGH PERFORMANCE CLEANING CYCLE C ontinuous endoscope channel monitoring & blockage detection D edicated hookup ensures all channels are connected & fully reprocessed D ouble wash feature...

 Open the catalog to page 4
ADVANTAGE PLUS® Pass-Thru Endoscope-5

ENDODRY™ STORAGE & DRYING SYSTEM – ENSURING MAXIMUM SAFETY MEDIVATORS™ ENDODRY Storage & Drying System sets a higher standard for endoscope drying and storage by ensuring your flexible endoscopes remain bacteria free during storage. The ENDODRY cabinet continuously forces HEPA filtered air through all endoscope channels and the outer sheath. This eliminates residual moisture and results in a completely dry endoscope and a reduced risk of bacterial growth. The short drying cycle also improves scope turn-around time. PROTECT FLEXIBLE ENDOSCOPES FROM DAMAGE AND CONTAMINATION T he cabinet works with...

 Open the catalog to page 5
ADVANTAGE PLUS® Pass-Thru Endoscope-6

Product Specifications ADVANTAGE PLUS® PASS-THRU ENDOSCOPE REPROCESSOR AND ENDODRY™ STORAGE & DRYING SYSTEM ADVANTAGE PLUS®, RAPICIDE®, INTERCEPT®, ENDORA™ and ENDODRY™ are trademarks and registered trademark of Medivators Inc. ADASPOR® is a registered trademark of Cantel Medical (Italy) S.r.l. MEDIVATORSA Cantel Medical Company Medivators Inc. 14605 28th Avenue North id Medivators BV Sourethweg 11 6422 PC Heerlen The Netherlands Tel: +31.45.5.471.471 Fax: +31.45.5.429.595 Cantel Medical (UK) Limited Wolseley House Staffordshire Technology Park Beaconside, Stafford ST18 0GA United Kingdom Tel:...

 Open the catalog to page 6
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.