video corpo

ADVANTAGE PLUS™ Pass-Thru
2Pages

{{requestButtons}}

Catalog excerpts

ADVANTAGE PLUS™ Pass-Thru - 1

ADVANTAGE PLUS® Pass-Thru AER System Specifications Electrical Safety Certifications ETL Intertek Listed #75811 UL Standard 61010-1 EN Standard 61010-1 CSA/CAN Standard C22.2, No. 61010-1 Electrical Requirements 120 VAC ± 10%: single phase, 60HZ; 1200 Watts Dimensions 78 %" H x 51 W x 31 y4" D (200 cm H x 130.6 cm W x 79.2 cm D) Weight 882 lbs (400 kgs) Water Supply Minimum flow rate: 1.32 GPM (5 LPM) at 30 to 87 PSI (2 to 6 bar) Water Temperature: 35°C ± 2°C Air Supply 58 to 145 psi (4 to 10 bar). Min flow of 1.5 cfm (0.71 L/sec) Optional air compressor available ADVANTAGE PLUS" Pass-Thru Automated Endoscope Reprocessor I Reprocess ADVANTAGE PLUS™ Pass-Thru AER System Ordering Information -North America Model Number Description ADVPT-3007 ADVANTAGE PLUS™ Pass-Thru AER, 120V (w/air compressor) ADVPT-3008 ADVANTAGE PLUS™ Pass-Thru AER, 120V (w/out air compressor) Part Number Description 4 bottles/case - 2 Part A, 2 Part B ML02-0116 RAPICIDE™ PA High-Level Disinfectant (Canada) 4 bottles/case - 2 Part A, 2 Part B ML02-0118 RAPICIDE™ PA Test Strips (2 bottles/pack, 100 strips/bottle) ML02-0145 INTERCEPT™ PLUS Detergent (2 bottles/case) CAS-1000 Endoscope Transport Cassette 1 Rutala, W.A., Weber, D. J., and the Healthcare Infection Control Practices Advisory Committee (2008). Guideline for Disinfection and Sterilization in Healthcare Facilities (Last update: February 15, 2017). Retrieved from CDC: https://www.cdc.gov/infectioncontrol/pdf/guidelines/disinfection-guidelines.pdf 2 UK Department of Health (2016). Health Technical Memorandum 01-06: Decontamination of flexible endoscopes: Part B - Design and installation. Retrieved from: https://www.gov.uk/government/uploads/system/uploads/ attachment_data/file/530420/HTM0106_PartB.pdf 3 Association for the Advancement of Medical Instrumentation and American National Standards Institute (2015). ANSI/AAMI ST91:2015 Flexible and semi-rigid endoscope processing in health care facilities. 4 Society of Gastroenterology Nurses and Associates (2012). Standards of Infection Control in Reprocessing of Flexible Gastrointestinal Endoscopes. Retrieved from: https://www.sgna.org/Portals/0/Education/PDF/Standards-Guidelines/sgna_stand_of_infection_control_0812_FINAL.pdf 5 Testing data on file. Reprocessing Reimagined Intuitive Design Trusted Technology Efficient Workflow Reliable Outcomes % CANTEL MEDICAL Cantel Medical (Canada) Toll Free Phone: +1.844.34fi.5636 90 Gough Road, Unit 1 Toll Free Fax: +1.844.34fi.5637 Markham, ON L3R 5V5 Email: inf o@cante I medical.ca # CANTEL MEDICAL © 2017 Medivators Inc. P/N 50098-1498A-ENCAN

Open the catalog to page 1
ADVANTAGE PLUS™ Pass-Thru - 2

THE COMPLETE CIRCLE OF PROTECTION As the global vanguard in infection prevention, only Cantel Medical delivers the Complete Circle of Protection, a full-value, proactive partnership dedicated to helping you remove risk, streamline operational efficiencies and optimize your success. High-level disinfection is the cornerstone of infection prevention. Reprocessing technologies from Cantel are designed to ensure patient safety by adhering to the strictest of standards for high level disinfection, optimizing workflow efficiency, and delivering versatility by supporting a wide range of endoscopes...

Open the catalog to page 2

All STERIS - CANTEL catalogs and technical brochures

  1. DEFENDO™

    6 Pages

  2. Dry & Store

    4 Pages

  3. DSD EDGE ®

    4 Pages

  4. MediClean EZ

    2 Pages