1. Catalogs
  2. STERIS - CANTEL
  3. ADVANTAGE PLUS™
video corpo

ADVANTAGE PLUS™

ADVANTAGE PLUS™

ADVANTAGE PLUS™

Product catalog summary
Overview: The ADVANTAGE PLUS™ Endoscope Reprocessing System is a sophisticated automated system designed for the high-level disinfection of endoscopes, ensuring patient safety and operational efficiency. It is compatible with all flexible endoscopes and validated for various types, including TEE probes and cystoscopes.
Specifications: The system dimensions are 59 H x 45 W x 36 D inches, with a weight of 400 lbs. It requires an electrical input of 100-240 VAC and a water supply with a minimum flow rate of 1.32 GPM. The system is certified under multiple safety standards, including UL and EN.
Key Features:
  • Comprehensive Monitoring: Ensures proper hookup and monitors channels for blockages.
  • Automated Cleaning: Eliminates manual cleaning variability and optimizes the HLD process.
  • Leak Testing and Alcohol Flush: Facilitates drying and minimizes repair costs.
  • Networking Capabilities: Allows for centralized data collection and remote diagnostics.
  • RAPICIDE™ PA Disinfectant: Offers low-temp, aldehyde-free disinfection, reducing worker exposure.
Operational Benefits: The system supports a complete circle of protection by integrating with the ENDORA™ Track & Trace System, providing hands-free lid operation, and offering asynchronous basin operation for flexibility.
Ordering Information: Available in North America and internationally, with options for systems with or without an air compressor.
See more

Catalog excerpts

ADVANTAGE PLUS™-1

ADVANTAGE PLUS™ Endoscope Reprocessing System Ordering Information - North America Model Number Description ADV-1007 ADVANTAGE PLUS Endoscope Reprocessing System for RAPICIDE™ PA Disinfectant with air compressor ADV-1008 ADVANTAGE PLUS Endoscope Reprocessing System for RAPICIDE PA Disinfectant without air compressor CAS-1000 Endoscope Transport Cassette ADVANTAGE PLUS Endoscope Reprocessing System Ordering Information - International Model Number Description ADV-2001 ADVANTAGE PLUS Endoscope Reprocessing System for RAPICIDE PA Disinfectant with air compressor ADV-2002 ADVANTAGE PLUS Endoscope Reprocessing System for RAPICIDE PA Disinfectant without air compressor ADVANTAGE PLUS™, ENDORA™ and RAPICIDE™ are trademarks of Medivators Inc. Dimensions 59 H x 45 W x 36 D inches (150 H x 114 W x 92 D cm) Lid Height: Open - 54" (137 cm), Closed - 38 " (97 cm) Depth with air compressor: 37.5" (95.cm) Weight 400 lbs (182 kg) Electrical Requirements 100-240 VAC ± 10%: single phase, 50/60HZ; 1000 Watts Electrical Safety Certifications ETL Intertek Listed #75811 UL Standard 61010-1 EN Standard 61010-1 CSA/CAN Standard C22.2, No. 61010-1 Water Supply Minimum flow rate: 1.32 GPM (5 LPM) at 35 to 87 PSI (2.4 to 6 bar) Water Temperature: (35°C ± 2°C) - North America; (25°C ± 2°C) - International Water Hardness: less than 12 gpg (200 ppm) Pre-filter wall space: 26 H x 38 W x 6 D inch (66 H x 96 W x 15 D cm) Basin Size 19 W x 17 L x 7 D inch (48 H x 43 L x 18 D cm) Cantel Medical (Canada) Toll Free Phone: +1.844.34fi.5636 90 Gough Road, Unit 1 Toll Free Fax: +1.844.34fi.5637 Markham, ON L3R 5V5 Email: inf o@cante I medical.ca ADVANTAGE PLUS" Endoscope Reprocessing System I Reprocess

 Open the catalog to page 1
ADVANTAGE PLUS™-2

THE COMPLETE CIRCLE OF PROTECTION As the global vanguard in infection prevention, only Cantel Medical delivers the Complete Circle of Protection, a full-value, proactive partnership dedicated to helping you remove risk, streamline operational efficiencies and optimize your success. High-level disinfection is the cornerstone of infection prevention. Reprocessing technologies from Cantel are designed to ensure patient safety by adhering to the strictest of standards for high level disinfection, optimizing workflow efficiency, and delivering versatility by supporting a wide range of scopes. ADVANTAGE...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.