Amsco® Examiner® 10 Examination Lighting System
4Pages

{{requestButtons}}

Catalog excerpts

Amsco® Examiner® 10 Examination Lighting System - 1

AMSCO® EXAMINER® 10 EXAMINATION LIGHTING SYSTEM APPLICATION The Amsco Examiner 10 Examination Lighting System, available in three configurations, provides cool, colorcorrected light for examination, treatment and emergency areas. DESCRIPTION Ceiling-mounted fixtures are suspended on a seamless, vertical tube (cut to size by others). The lighthead suspension arm slips into a casting on the lower end of the vertical tube and is secured by a close-fitting hinge pin. The upper end of the vertical tube is welded to a steel ceiling plate. A brushedaluminum cover is furnished to conceal the plate. The vertical tube may be cut to length to suit various ceiling heights. STERIS recommends a minimum ceiling height of 8' (2438 mm) to a maximum ceiling height of 11' (3353 mm). Wall-mounted fixtures are furnished with a predrilled mounting bracket assembly. With this type of mounting, the lighthead may be extended, or, when not in use, the lighthead folds close to the wall. Optional 14" (356 mm) extension available to maximize reach. Mobile floor stand fixtures are provided with a vertical stand. The stand supports the lighthead suspension arm. The stand is affixed to a sturdy metal base having ball-bearing casters with neoprene wheels. The stand is 67" (1702 mm) high with a 34" (864 mm) base. Mobile floor units are equipped with a 20' (6096 mm) power cord to provide more area coverage. STANDARDS (Typical only - some details may vary.) IEC 60601-1, Medical Electrical Equipment – Part 1: General Requirements for Safety,1988 (General), Amendment 1, 199111, Amendment 2, 1995-03, as certified by Intertek Testing Services, Inc. IEC 60601-1-2, (1st Edition, 1993-04), Medical Electrical Equipment -Part 1: General Requirements for Safety; Electromagnetic Compatibility – Requirements and Tests (General), as certified by Intertek Testing Services, Inc. Medical Device Directive (93/42/ EEC) FDA Good Manufacturing Practices Regulation 21CFR 820 for Medical Devices FEATURES UL 60601-1 Standard for Medical Electrical Equipment, Part 1: General Requirements for Safety, as certified by Intertek Testing Services, Inc. State-of-the-art design – 150-watt, quartz-halogen lamp (rated at 500 hours) and dichroic, coated, parabolic reflector. The reflector has a color-correcting cold mirror which reflects a controlled portion of the visible light onto a Pyrex®1 diffuser. The diffuser smooths, blends and directs the light to the examination site. The cold mirror passes a majority of the heat (from the lamp) up through the vented lighthead cover, away from the examination site. CAN/CSA C22.2 No. 601.1-M90 Standard for Medical Electrical Equipment, as certified by Intertek Testing Services, Inc. 1. Pyrex® is a registered trademark of Corning Incorporated. Each lighting fixture meets applicable requirements of the following listings and standards, and carries the appropriate symbol: The Selections Checked Below Apply To This Equipment MODEL ❑ Ceiling Mounted ❑ Single ❑ With 14" (356 mm) Horizontal Suspension Arm Extension ❑ Without Horizontal Suspension Arm Extension ❑ Dual – with 14" Horizontal Suspension Arm Extension ❑ Wall Mounted ❑ With one 14" (356 mm) Horizontal Suspension Arm Extension ❑ Without Horizontal Suspension Arm Extension ❑ Mobile Floor Stand Fixture – 34" (864 mm) Base 67" (1702 mm) Stand OPTIONS ❑ Seismic Design (for Ceiling-mounted Fixtures) ACCESSORIES ❑ One 14" (356 mm) Extension (for Wall or Ceilingmounted Fixtures) ❑ Adapter Plate (to make Burton 4-15/16" bolt circle suitable for Examiner 10) ❑ Sterile Handle Kit (One Required for Each Lighthead) ❑ 200-240 Volt Transformer Item ________________________ Location(s)___________________ ____________________________ SD243 (02/01/10)

Open the catalog to page 1
Amsco® Examiner® 10 Examination Lighting System - 2

Glare-reducing construction - glare is blocked by a retro- reflector positioned so as not to interfere with the light pattern. Easy lamp replacement - no tools are required. One extra lamp is furnished with each fixture. Smooth, exact positioning - without drifting, accomplished by using positioning ring on the lighthead outer cover. The lighthead is mounted in a movable yoke attached by a swivel to a spring-balanced suspension arm assembly. The swivel allows the yoke to be maneuvered through a wide range of positions. The power ON/OFF switch is on the yoke; the power cord and positioning...

Open the catalog to page 2
Amsco® Examiner® 10 Examination Lighting System - 3

Single Ceiling-Mounted Fixture* Mobile Floor Stand Fixture 101° Sweep Finished Ceiling 101° Sweep Cut to Req’d Length 20’ (6096 mm) Long Cord 27-1/2" (698 mm) 2-3/4" (70 mm) 27-1/2" (698 mm) 26° 26° Recommended Minimum Mounting Height 6'-4" 12-11/16" (322 mm) Diameter Three Prong Grounded Plug A 12-11/16" (322 mm) Diameter * 8'0" (2438.4 mm) minimum ceiling height to 11'0" (3353 mm) maximum ceiling height. 6" (152.4 mm) Dual Ceiling-Mounted Fixture* Finished Floor Cut to Req’d Length 101° Sweep 27-1/2" (698 mm) 26° 12-11/16" (322 mm) Diameter Finished Ceiling 101° Sweep 27-1/2" (698 mm)...

Open the catalog to page 3
Amsco® Examiner® 10 Examination Lighting System - 4

Ceiling-Mounted Fixture Mounting Screw Mounting Screw PLAN VIEW Electrical Service Mounting Plate Wall-Mounted Fixture Electrical Junction Finished Wall Finished Ceiling Three Wire Service For Further Information, contact: SD243 ©2010, STERIS Corporation. All rights reserved. (02/01/10) This document is intended for the exclusive use of STERIS Customers, including architects or designers. Reproduction in whole or in part by any party other than a Customer is prohibited.