AMSCO LD202 IN-CEILING LIGHTING SYSTEM
4Pages

{{requestButtons}}

Catalog excerpts

AMSCO LD202 IN-CEILING LIGHTING SYSTEM - 1

AMSCO® LD202 IN-CEILING LIGHTING SYSTEM APPLICATION For cool, color-corrected illumination appropriate for focused areas such as birthing, critical care areas and minor surgery. Non-imposing installation assists in creating an unobtrusive, comfortable atmosphere. DESCRIPTION The Amsco LD202 In-Ceiling Lighting System includes single or dual ceiling mounted lightheads with dichroic reflectors and a wall mounted control panel. The lighthead mounts flush in a ceiling while the control panel is positioned in a wall. Light beam may be moved and beam intensity level adjusted via a remote, wall-mounted control panel. Position control adjusts angle of lamp to bed in any direction. Five discrete intensity levels are available. Unit operates on standard 120-220 Volt electrical service. Other electrical configurations are available for international use. Typical only – details may vary Unobtrusive design of lighthead and wall control do not interfere with comfortable atmosphere desired in birthing rooms and critical care applications. STANDARDS Lighting fixture meets the applicable requirements of the following standards and/or regulations: • Canadian Standards Association (CSA) Standard Light beam adjusts remotely for optimum positioning. Five discrete intensity levels ensure proper illumination for the work area. C22.2 No. 601.1-M90, Standard for Electro-Medical LED intensity display on wall control, indicates intensity level. Equipment, as certified by ETL Testing Laboratories, Inc. Control functions indicated by intuitive graphic symbols. • EN 55011: Group I, Class B, Emissions Testing, as certified by ETL Testing Laboratories, Inc. • EN 60601-1: 1993 Amendment 2, 1995, Electrical Safety, as certified by ETL Testing Laboratories, Inc. • FDA Good Manufacturing Practices Regulations 21CFR820 for Medical Devices. Membrane-type wall control touchpad is easy to clean. Dichroic-coated reflector design radiates heat away from the patient. Low-voltage wall control simplifies installation with class 2 wiring. LD202 light uses same proven, reliable lamp as Quantum® light series. • IEC 601-1-2: 1993, Electromagnetic Compatability, as certified by ETL Testing Laboratories, Inc. INSTALLATION • Medical Device Directive (93/42/EEC) An LD202 wall control is required for each single or dual installation. Recessed wall control panel houses intensity control and position control. Each includes 100 feet (30 meters) of NEC type CM cable for connection between the lighthead(s) and wall control. NOTE: Cable is not plenum rated. • Underwriters Laboratories (UL) Standard 60601-1, 1st ED, as certified by ETL Testing Laboratories, Inc. FEATURES Nominal light intensity of 4000 footcandles (43,000 lux) from each lighthead. STERIS furnishes all components necessary to obtain a complete working unit, ready for (but not including) installation and connection to builders' electrical supply. Above-ceiling support is not provided by STERIS. The Selections Checked Below Apply To This Equipment LIGHT CONFIGURATION OPTION ❒ Single Lighthead ❒ Dual Lighthead ❑ Seismic Design Item ______________ Location(s)_________ _______________ SD582 (02/01/10)

Open the catalog to page 1
AMSCO LD202 IN-CEILING LIGHTING SYSTEM - 2

PREVENTIVE MAINTENANCE ENGINEERING DATA A global network of skilled service specialists can help provide periodic inspections and adjustments to help assure low-cost peak performance. STERIS representatives can provide information regarding annual maintenance agreements. 1. For single lighthead system, position lighthead over centerline of bed. For dual lighthead systems, space lamps 48" (1219 mm) apart on center. 2. Lighthead positioning may vary depending on specific 3. Consult equipment drawings for additional installation 4. Specifications and descriptions are subject to change without...

Open the catalog to page 2
AMSCO LD202 IN-CEILING LIGHTING SYSTEM - 3

Refer to the Following Equipment Drawings for Installation Details 150824-642 LD202 SURGICAL LIGHT DUAL SYSTEM - LABOR AND DELIVERY ROOM APPLICATION 150824-801 LD202 SURGICAL LIGHT SINGLE SYSTEM - LABOR AND DELIVERY ROOM APPLICATION Building Superstructure Chain (supplied by STERIS) 15" (381 mm) Square Bolt Hole Turnbuckles 3/8" Eye Hooks 12" (305 mm) NOTE: 1" (25 mm) clearance must be provided on each side of the lighthead shell for ventilation. 4" (102 mm) Minimum Equipment Drawing Title 16" (406 mm) Minimum Equipment Drawing Number LD202 Lighthead on ti lla a Ceiling Tile Ceiling Grid...

Open the catalog to page 3
AMSCO LD202 IN-CEILING LIGHTING SYSTEM - 4

Refer to the Following Equipment Drawings for Installation Details Equipment Drawing Number Equipment Drawing Title 150824-642 LD202 SURGICAL LIGHT DUAL SYSTEM - LABOR AND DELIVERY ROOM APPLICATION 150824-801 LD202 SURGICAL LIGHT SINGLE SYSTEM - LABOR AND DELIVERY ROOM APPLICATION 40-1/2" (1029 mm) * 35" (889 mm) * Ceiling Height 29-1/2" (749 mm) * 10'-0" (3048 mm) Minimum clearance to support structure: Chain – 16" (406 mm) Rigid Frame – 20" (508 mm) 9'-0" (2743 mm) at ll ta ns rI Fo ot N 8'-0" (2438 mm) n io Position access panel latches away from bed For single lighthead system, position...

Open the catalog to page 4