RELIANCE EPS Endoscope Processing System
4Pages

{{requestButtons}}

Catalog excerpts

RELIANCE EPS Endoscope Processing System - 1

Finally, a safe and efficient alternative to commonly-used high level disinfection (HLD) solutions and processors. Safe for your staff Safe for your patients Safe and efficient for your GI Department The Reliance™ EPS Endoscope Processing System and the Reliance™ DG oxidizing chemistry offer a safe alternative to aldehydes in a validated system designed specifically for use in the GI Department. The NEXT step in safety for your GI Department

Open the catalog to page 1
RELIANCE EPS Endoscope Processing System - 2

Reliance™ EPS Endoscope Processing System Chemistry Delivery System Easy-to-load container for Reliance DG single use, dry oxidative chemistry HLD solution is generated within the processor Automated Leak Test for Endoscopes Boot Technology Creates a virtually connector-less system Optional leak detection after pre-cleaning process Process Indicator Verifies that an effective dose of HLD solution was generated Valve Irrigators Actuates suction valves for complete HLD solution contact

Open the catalog to page 2
RELIANCE EPS Endoscope Processing System - 3

Key Features at Glance…A Total System Take the Next Stepain Safety with Reliance EPS Printer Documentation with every cycle Verification of critical process parameters Touch Button Controls Single or dual scope reprocessing capabilities Optional wash phases One touch decontamination cycles Real time cycle status Audible alarms Barcode Scanner Allows positive identification on cycle print out for Operator Device Procedure Patient Physician Bag-in-a-Box Compartment Klenzyme® Enzymatic Cleaner for washing phases CIP 200® Process Cleaner for chemical decontamination cycles Storage area The...

Open the catalog to page 3
RELIANCE EPS Endoscope Processing System - 4

The Reliance EPS processor and Reliance DG chemistry are designed and validated to perform together. The value of a total system: Safe for your Staff Eliminate staff exposure hazards associated with toxic glutaraldehyde and other aldehyde-based HLD solutions by utilizing a dry oxidizing chemistry Greatly diminishes chemical exposure and requires no special venting, measuring, mixing or pouring Part Number Preferred Configuration Reliance Endoscope Processor, 208 V, 60 Hz, 3-Ph (includes: basic processor and all options listed below including automatic leak test and pressure regulator...

Open the catalog to page 4