Catalog excerpts
Trochanteric Gamma3™ Locking Nail Key Statistics Stable and Non-Stable Intertrochanteric Fractures 120°, 125°, 130° 0° 15.5mm 11mm 180mm Self-Tapping Thread Diameter: 10.5mm Core Diameter: 6.7mm Lengths: 75-120mm Fully Threaded (or Partially Threaded) Self-Tapping Cortical Screws Diameter: 5mm Lengths: 25-120mm 8mm x 17.5mm Titanium Alloy with Type II Anodization (Ti-6Al-4V) Indications: Target Angles: Anteversion: Proximal Diameter: Distal Diameter: Length: Lag Screws: Distal Screw: Distal Locking Screw The Compact Titanium Version of the TM Gamma Nail System Long Gamma3™ Locking Nail Key Statistics Sub-Trochanteric Fractures, Non-Stable Intertrochanteric Fractures, Combination Intertrochanteric/Sub-Trochanteric Fractures, Pathological/Impending Pathological Fractures 120°, 125°, 130° 10° 15.5mm 11, 13, 15mm 280-480mm, left and right Self-Tapping Thread Diameter: 10.5mm Core Diameter: 6.7mm Lengths: 75-120mm Fully Threaded (or Partially Threaded) Self-Tapping Cortical Screws Diameter: 5mm Lengths: 25-120mm 8mm x 17.5mm Titanium Alloy with Type II Anodization (Ti-6Al-4V) Target Angles: Anteversion: Proximal Diameter: Distal Diameter: Lengths: Lag Screws: Distal Screw: Set Screw: Material: REFERENCES: Distal Locking Screws 1. Grosse A., Favreul E., Tagland G., "The GammaTM Nail; The results at the CTO Strasbourg" Paper presented at the International Symposium "Recent Advances in Locking Nails", Hong Kong, 1992 2. Taglang G. Favreul E., "Results from the Centre de Traumatologie et d’Orthopedie, Strasbourg": Paper presented at the Advanced Course in Intramedullary Locking Nailing, Courchevel, France, February 1991. 3. Leung K.S. et a., (Prince of Wales Hospital, Hong Kong), J. Bone Joint Surg [Br] 1992; 74B, 3:345-51 4. Boriani S. et al, results of Multicentric Italian Experience on the Gamma® Nail. A report on 648 cases, Orthopedics 1991; 14, 12: 1307-1314. 5. Radford, P.J., (University Hospital Queen’s Medical Centre, Nottingham, England)": Comparison of results of the GammaTM Nail and Dynamic Hip Screw in Extracapsular fractures of the Proximal Femur.": Paper presented at Advanced Course in Intramedullary Locking Nailing, Courchevel, France, February 1991. 6. Williams, J.J. Cohen, P.Z. Pittsburgh Orthopaedic Journals, 1990, Volume 1, pages 20-23. 7. DeGroote, W., Van Hoye M. et al, (St. Jan General Hospital, Bruge/Middelheim General Hosptial, Antwerp, Belgium): "The GammaTM Locking Nail in the treatment of trochanteric fractures" Article in press. 325 Corporate Drive Mahwah NJ 07430 t: 201-831-5000 t: 800-447-7836 www.stryker.com The information presented in this brochure is intended to demonstrate the breadth of Stryker product offerings. Always refer to the package insert, product label and/or user instructions before using any Stryker product. Surgeons must always rely on their own clinical judgment when deciding which treatments and procedures to use with patients. Products may not be available in all markets. Product availability is subject to the regulatory or medical practices that govern individual markets. Please contact your Stryker representative if you have questions about the availability of Stryker products in your area. The marks bearing the symbol ™ are trademarks of Stryker. The marks bearing the symbol ® are registered trademarks of Stryker. Literature Number: LG3B Rev.1 GC/GS 5m 04/05 Copyright © 200
Open the catalog to page 1Trochanteric Gamma3™ Locking Nail Long Gamma3™ Locking Nail The Gamma3™ instrument set design is based on the T2™/S2™ IM Nail instrument platform. Gamma3™ Basic Instrument Tray Catalog # Titanium Alloy with Type II Anodization (Ti-6Al-4V) Designed to Address Stable and Non-Stable Intertrochanteric Fractures Option for the Younger or Smaller Patient where Bone Removal is a Concern The Alternative to Compression Hip Screws May Reduce Trauma to the Patient Through Closed Operating Technique3,4 Limited Incision at the Tip of the Greater Trochanter May Result in Minimal Blood Loss and...
Open the catalog to page 2Trochanteric Gamma3™ Locking Nail Long Gamma3™ Locking Nail The Gamma3™ instrument set design is based on the T2™/S2™ IM Nail instrument platform. Gamma3™ Basic Instrument Tray Catalog # Titanium Alloy with Type II Anodization (Ti-6Al-4V) Designed to Address Stable and Non-Stable Intertrochanteric Fractures Option for the Younger or Smaller Patient where Bone Removal is a Concern The Alternative to Compression Hip Screws May Reduce Trauma to the Patient Through Closed Operating Technique3,4 Limited Incision at the Tip of the Greater Trochanter May Result in Minimal Blood Loss and...
Open the catalog to page 3Trochanteric Gamma3™ Locking Nail Long Gamma3™ Locking Nail The Gamma3™ instrument set design is based on the T2™/S2™ IM Nail instrument platform. Gamma3™ Basic Instrument Tray Catalog # Titanium Alloy with Type II Anodization (Ti-6Al-4V) Designed to Address Stable and Non-Stable Intertrochanteric Fractures Option for the Younger or Smaller Patient where Bone Removal is a Concern The Alternative to Compression Hip Screws May Reduce Trauma to the Patient Through Closed Operating Technique3,4 Limited Incision at the Tip of the Greater Trochanter May Result in Minimal Blood Loss and...
Open the catalog to page 4Trochanteric Gamma3™ Locking Nail Key Statistics Stable and Non-Stable Intertrochanteric Fractures 120°, 125°, 130° 0° 15.5mm 11mm 180mm Self-Tapping Thread Diameter: 10.5mm Core Diameter: 6.7mm Lengths: 75-120mm Fully Threaded (or Partially Threaded) Self-Tapping Cortical Screws Diameter: 5mm Lengths: 25-120mm 8mm x 17.5mm Titanium Alloy with Type II Anodization (Ti-6Al-4V) Indications: Target Angles: Anteversion: Proximal Diameter: Distal Diameter: Length: Lag Screws: Distal Screw: Distal Locking Screw The Compact Titanium Version of the TM Gamma Nail System Long Gamma3™ Locking Nail Key...
Open the catalog to page 5All Stryker catalogs and technical brochures
-
VariAx® DistalFibula
20 Pages
-
ACCOLADE® II
20 Pages
-
VariAx® 2
20 Pages
-
TruRize® Clinical Chair
2 Pages
-
TruRize™ Clinical Chair
4 Pages
-
Prime TC®
4 Pages
-
ENT navigation system
7 Pages
-
Smart Equipment Management
3 Pages
-
OrthoMap®
4 Pages
-
AxSOS 3® Titanium
36 Pages
-
Luxor
4 Pages
-
Humeral Nailing System
44 Pages
-
AVS Anchor® -C
2 Pages
-
Aviator™
2 Pages
-
Aero® -C
6 Pages
-
Stryker Biologics
46 Pages
-
Escalate®
16 Pages
-
Dynatran
13 Pages
-
Reflex®
24 Pages
-
OASYS®
44 Pages
-
SurgiCount
4 Pages
-
Reusable Cuff
2 Pages
-
Disposable Cuff
2 Pages
-
SmartPump
2 Pages
-
Patient Education
2 Pages
-
Revolution
6 Pages
-
Cast Vac
2 Pages
-
Cast Cutter
2 Pages
-
Stryker NAV3i
4 Pages
-
S3 MedSurg Bed
8 Pages
-
Asnis ® Micro Xpress
2 Pages
-
EasyClip
2 Pages
-
Universal Neuro III
10 Pages
-
Right Angled Screwdriver
8 Pages
-
Neptune E-SEP
2 Pages
-
Neptune 2
2 Pages
-
InterPulse - Orthopaedics
4 Pages
-
Mixevac III
2 Pages
-
System 7 Family
7 Pages
-
SDC 3
2 Pages
-
SmartTip ™
3 Pages
-
Label Changes
2 Pages
-
the Mill
2 Pages
-
CBC II
2 Pages
-
Scorpio ®Knee TS
6 Pages
-
GMRS
13 Pages
-
trident
12 Pages
-
Gamma3 U-Blade Lag Screw
18 Pages
-
Gamma3 Fragment Control Clip
6 Pages
-
Gamma3 Long Nail R2.0
48 Pages
-
Gamma3 Trochanteric Nail 180
48 Pages
-
CD4 & SABO2 Family
5 Pages
-
System 7 Sterilization Case
2 Pages
-
System 7 Battery
2 Pages
-
System 7 Precision
2 Pages
-
System 7
7 Pages
-
ACL Instrumentation Brochure
6 Pages
-
C-Arm T racking System
2 Pages
-
company overview
12 Pages