Product catalog summary
Overview: The Gamma3™ Nail System by Stryker is a titanium-based system designed for treating various femoral fractures, including stable and non-stable intertrochanteric, sub-trochanteric, and pathological fractures. It is made from a titanium alloy with Type II anodization, providing a stable construct that supports early weight bearing.
Specifications:
  • Target Angles: 120°, 125°, 130°
  • Anteversion: 0° for Trochanteric, 10° for Long Nail
  • Proximal Diameter: 15.5mm
  • Distal Diameter: 11mm (Trochanteric), 11, 13, 15mm (Long Nail)
  • Lengths: 180mm (Trochanteric), 280-480mm (Long Nail)
  • Lag Screws: Self-tapping, 10.5mm diameter, 75-120mm lengths
  • Distal Screws: Fully or partially threaded, 5mm diameter, 25-120mm lengths
  • Material: Titanium Alloy (Ti-6Al-4V)
Key Features:
  • Designed for both stable and non-stable intertrochanteric fractures.
  • Suitable for younger or smaller patients where bone removal is a concern.
  • Alternative to compression hip screws, potentially reducing trauma through a closed operating technique.
  • Limited incision at the greater trochanter may result in minimal blood loss and reduced operative time.
  • Early weight bearing is typically allowed due to the stable construct.
Instrument Trays:
  • Basic Instrument Tray: Includes T-Handle, K-Wire, Screwdriver, Nail Holding Bolt, Targeting Arm, and various sleeves and guides.
  • Optional Instrument Tray: Includes K-Wire for Condyle Screws, Guide Pin, Conical Reamers, Cannulated Cutter, and other specialized tools.
Procedures and Recommendations:
  • Surgeons should rely on their clinical judgment when selecting treatments and procedures.
  • Product availability may vary based on local regulatory and medical practices.
Clinical References: The document references multiple studies and papers presented at international symposiums, highlighting the effectiveness of the Gamma™ Nail System in various clinical settings.
See more

Catalog excerpts

Gamma3 T-1

Trochanteric Gamma3™ Locking Nail Key Statistics Stable and Non-Stable Intertrochanteric Fractures 120°, 125°, 130° 0° 15.5mm 11mm 180mm Self-Tapping Thread Diameter: 10.5mm Core Diameter: 6.7mm Lengths: 75-120mm Fully Threaded (or Partially Threaded) Self-Tapping Cortical Screws Diameter: 5mm Lengths: 25-120mm 8mm x 17.5mm Titanium Alloy with Type II Anodization (Ti-6Al-4V) Indications: Target Angles: Anteversion: Proximal Diameter: Distal Diameter: Length: Lag Screws: Distal Screw: Distal Locking Screw The Compact Titanium Version of the TM Gamma Nail System Long Gamma3™ Locking Nail Key Statistics Sub-Trochanteric Fractures, Non-Stable Intertrochanteric Fractures, Combination Intertrochanteric/Sub-Trochanteric Fractures, Pathological/Impending Pathological Fractures 120°, 125°, 130° 10° 15.5mm 11, 13, 15mm 280-480mm, left and right Self-Tapping Thread Diameter: 10.5mm Core Diameter: 6.7mm Lengths: 75-120mm Fully Threaded (or Partially Threaded) Self-Tapping Cortical Screws Diameter: 5mm Lengths: 25-120mm 8mm x 17.5mm Titanium Alloy with Type II Anodization (Ti-6Al-4V) Target Angles: Anteversion: Proximal Diameter: Distal Diameter: Lengths: Lag Screws: Distal Screw: Set Screw: Material: REFERENCES: Distal Locking Screws 1. Grosse A., Favreul E., Tagland G., "The GammaTM Nail; The results at the CTO Strasbourg" Paper presented at the International Symposium "Recent Advances in Locking Nails", Hong Kong, 1992 2. Taglang G. Favreul E., "Results from the Centre de Traumatologie et d’Orthopedie, Strasbourg": Paper presented at the Advanced Course in Intramedullary Locking Nailing, Courchevel, France, February 1991. 3. Leung K.S. et a., (Prince of Wales Hospital, Hong Kong), J. Bone Joint Surg [Br] 1992; 74B, 3:345-51 4. Boriani S. et al, results of Multicentric Italian Experience on the Gamma® Nail. A report on 648 cases, Orthopedics 1991; 14, 12: 1307-1314. 5. Radford, P.J., (University Hospital Queen’s Medical Centre, Nottingham, England)": Comparison of results of the GammaTM Nail and Dynamic Hip Screw in Extracapsular fractures of the Proximal Femur.": Paper presented at Advanced Course in Intramedullary Locking Nailing, Courchevel, France, February 1991. 6. Williams, J.J. Cohen, P.Z. Pittsburgh Orthopaedic Journals, 1990, Volume 1, pages 20-23. 7. DeGroote, W., Van Hoye M. et al, (St. Jan General Hospital, Bruge/Middelheim General Hosptial, Antwerp, Belgium): "The GammaTM Locking Nail in the treatment of trochanteric fractures" Article in press. 325 Corporate Drive Mahwah NJ 07430 t: 201-831-5000 t: 800-447-7836 www.stryker.com The information presented in this brochure is intended to demonstrate the breadth of Stryker product offerings. Always refer to the package insert, product label and/or user instructions before using any Stryker product. Surgeons must always rely on their own clinical judgment when deciding which treatments and procedures to use with patients. Products may not be available in all markets. Product availability is subject to the regulatory or medical practices that govern individual markets. Please contact your Stryker representative if you have questions about the availability of Stryker products in your area. The marks bearing the symbol ™ are trademarks of Stryker. The marks bearing the symbol ® are registered trademarks of Stryker. Literature Number: LG3B Rev.1 GC/GS 5m 04/05 Copyright © 200

 Open the catalog to page 1
Gamma3 T-2

Trochanteric Gamma3™ Locking Nail Long Gamma3™ Locking Nail The Gamma3™ instrument set design is based on the T2™/S2™ IM Nail instrument platform. Gamma3™ Basic Instrument Tray Catalog # Titanium Alloy with Type II Anodization (Ti-6Al-4V) Designed to Address Stable and Non-Stable Intertrochanteric Fractures Option for the Younger or Smaller Patient where Bone Removal is a Concern The Alternative to Compression Hip Screws May Reduce Trauma to the Patient Through Closed Operating Technique3,4 Limited Incision at the Tip of the Greater Trochanter May Result in Minimal Blood Loss and Potentially...

 Open the catalog to page 2
Gamma3 T-3

Trochanteric Gamma3™ Locking Nail Long Gamma3™ Locking Nail The Gamma3™ instrument set design is based on the T2™/S2™ IM Nail instrument platform. Gamma3™ Basic Instrument Tray Catalog # Titanium Alloy with Type II Anodization (Ti-6Al-4V) Designed to Address Stable and Non-Stable Intertrochanteric Fractures Option for the Younger or Smaller Patient where Bone Removal is a Concern The Alternative to Compression Hip Screws May Reduce Trauma to the Patient Through Closed Operating Technique3,4 Limited Incision at the Tip of the Greater Trochanter May Result in Minimal Blood Loss and Potentially...

 Open the catalog to page 3
Gamma3 T-4

Trochanteric Gamma3™ Locking Nail Long Gamma3™ Locking Nail The Gamma3™ instrument set design is based on the T2™/S2™ IM Nail instrument platform. Gamma3™ Basic Instrument Tray Catalog # Titanium Alloy with Type II Anodization (Ti-6Al-4V) Designed to Address Stable and Non-Stable Intertrochanteric Fractures Option for the Younger or Smaller Patient where Bone Removal is a Concern The Alternative to Compression Hip Screws May Reduce Trauma to the Patient Through Closed Operating Technique3,4 Limited Incision at the Tip of the Greater Trochanter May Result in Minimal Blood Loss and Potentially...

 Open the catalog to page 4
Gamma3 T-5

Trochanteric Gamma3™ Locking Nail Key Statistics Stable and Non-Stable Intertrochanteric Fractures 120°, 125°, 130° 0° 15.5mm 11mm 180mm Self-Tapping Thread Diameter: 10.5mm Core Diameter: 6.7mm Lengths: 75-120mm Fully Threaded (or Partially Threaded) Self-Tapping Cortical Screws Diameter: 5mm Lengths: 25-120mm 8mm x 17.5mm Titanium Alloy with Type II Anodization (Ti-6Al-4V) Indications: Target Angles: Anteversion: Proximal Diameter: Distal Diameter: Length: Lag Screws: Distal Screw: Distal Locking Screw The Compact Titanium Version of the TM Gamma Nail System Long Gamma3™ Locking Nail Key Statistics...

 Open the catalog to page 5

All Stryker catalogs and technical brochures

  1. Hoffmann® 3

    2  Pages

  2. Gamma3

    2  Pages

  3. ICU Brochure

    6  Pages

Archived catalogs

  1. System 7

    7  Pages

  2. trident

    12  Pages

  3. GMRS

    13  Pages

  4. CBC II

    2  Pages

  5. the Mill

    2  Pages

  6. Label Changes

    2  Pages

  7. SmartTip ™

    3  Pages

  8. SDC 3

    2  Pages

  9. Mixevac III

    2  Pages

  10. Neptune 2

    2  Pages

  11. Neptune E-SEP

    2  Pages

  12. EasyClip

    2  Pages

  13. Stryker NAV3i

    4  Pages

  14. Cast Cutter

    2  Pages

  15. Cast Vac

    2  Pages

  16. Revolution

    6  Pages

  17. SmartPump

    2  Pages

  18. Reusable Cuff

    2  Pages

  19. SurgiCount

    4  Pages

  20. OASYS®

    44  Pages

  21. Reflex®

    24  Pages

  22. Escalate®

    16  Pages

  23. Aero® -C

    6  Pages

  24. Dynatran

    13  Pages

  25. Aviator™

    2  Pages

  26. Luxor

    4  Pages

  27. OrthoMap®

    4  Pages

  28. Prime TC®

    4  Pages

  29. VariAx® 2

    20  Pages

  30. ACCOLADE® II

    20  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.