1. Catalogs
  2. SUCO Robert Scheuffele GmbH & Co. KG
  3. E.1 "Performance", adjustable at factory
video corpo

E.1 "Performance", adjustable at factory

E.1 "Performance", adjustable at factory
1 / 12 PagesView full catalog

E.1 "Performance", adjustable at factory

Product catalog summary
Overview: This document provides comprehensive technical specifications and operational guidelines for electronic pressure switches, emphasizing their performance, adaptability, and application in various industrial settings.
Specifications:
  • Available in normally open (NO) and normally closed (NC) configurations with PNP transistor output.
  • Supply voltage ranges from 9.6 to 32 VDC, featuring reverse voltage protection.
  • Output current is 0.5 A, with short-circuit and overvoltage protection.
  • Adjustment range from 0 to 250 bar, with specified maximum overpressure and burst pressure.
  • Mechanical life expectancy of 5,000,000 pulsations at specified rise rates.
  • Accuracy is ±0.5% of full scale at room temperature, with long-term stability of ±0.1% per year.
  • Temperature ranges for operation and media depend on seal material (NBR, EPDM, FKM, TPE).
  • Protection classes include IP65, IP67, and IP6K9K, with various electrical connection options.
Technical Features:
  • Utilizes ceramic sensor technology with adjustable hysteresis and window function for pressure monitoring.
  • Switching points and delay times programmable via PPD05 device.
  • High adaptability for custom solutions, focusing on high overpressure protection and compact design.
Operational Guidelines:
  • Switching point accuracy and hysteresis are adjustable, with factory settings available.
  • Temperature compensation minimizes errors within specified ranges, depicted in a butterfly graph.
  • Service life and long-term stability influenced by operating conditions and measuring cell technology.
  • Output functions include PNP (plus-switching) and NPN (minus-switching) configurations.
Applications and Recommendations:
  • Suitable for high-volume deployment due to cost-effectiveness and adaptability.
  • Recommended for applications requiring precise pressure monitoring and control, with options for optical displays and menu control.
  • Not recommended for food applications due to the use of fluorine oil in some measuring cells.
Additional Specifications:
  • Sampling rate defines the number of samples per time unit from an analogue signal, indicating output signal response speed to pressure changes.
  • Response time is between 2 to 4 milliseconds, depending on the model.
Standards and Compliance:
  • Complies with the 2014/30/EU EMC Directive and marked with a CE mark.
  • Meets industrial EMC standards, including EN 61000-6-3 and EN 61000-6-2, and various immunity tests.
  • Designed for Group 2 fluids under the Pressure Equipment Directive 2014/68/EU.
Material Compatibility:
  • Highlights materials like titanium and stainless steel (AISI 303 and AISI 316L) for resistance and suitability for various applications, including corrosive media and oxygen/hydrogen applications.
Installation and Usage:
  • Should be installed by authorized specialists, adhering to safety regulations.
  • Guidance on mounting positions, IP protection classes, and thread types provided.
Technical Explanations:
  • Details on insulation strength, pressure peak dampening, and overpressure protection.
  • Advises on testing insulation strength and using pressure snubbers for transient pressure loads.
Conversion Charts:
  • Includes conversions between units like Pascal, bar, Torr, PSI, Kelvin, Celsius, and Fahrenheit.
RoHS and CE Marking:
  • Explains RoHS compliance and CE marking requirements.
  • Mechanical pressure switches with certain voltage levels fall under the Low Voltage Directive 2014/35/EU.
General Information:
  • Technical information based on testing and empirical values; suitability for specific applications should be verified by the user through field testing.
  • Technical changes are subject to occur.
See more

Catalog excerpts

E.1 "Performance", adjustable at factory-1

Electronic Pressure Switches sehctiwS erusserP cinortcelE 96

 Open the catalog to page 1
E.1 "Performance", adjustable at factory-2

Electronic pressure switches, Performance series adjustable at factory or programmable with programming device PPD05 • Very attractively priced electronic pressure switches, particularly for high volume deployment • High overpressure protection (up to 2 x) • Small, compact electronic switches • Broad diversity of electronic and mechanical connection options • Ceramic sensor in thick film technology • Monitoring of a pressure range due to window function • Hysteresis adjustable within a wide range (2 % - 98 %, set at factory) • Programming of switching points and switching delay time possible...

 Open the catalog to page 2
E.1 "Performance", adjustable at factory-3

Electronic pressure switches, Performance series Technical details Type: 11 Static pressure, dynamic pressure 30 to 50 % lower. Values refer to the hydraulic or pneumatic part of the electronic pressure switch. 2) 3 . . . 98 % with programming device PPD05 (see page 133). 3) Within the compensated temperature r

 Open the catalog to page 3
E.1 "Performance", adjustable at factory-4

Electrical connectors and threads x ~ 60 mm without socket device x ~ 77 mm with socket device Cable connection x ~ 47 mm (+ 25 mm bend relief ) Cable length ~ 2 m Sealing ring

 Open the catalog to page 4
E.1 "Performance", adjustable at factory-6

Technical explanations for electronic pressure switches What is an electronic pressure switch? An electronic pressure switch converts the medium pressure which is present at the measuring cell into a digital, electrical switch signal (ON / OFF). An electronic pressure switch is more complex than a mechanical pressure switch, and thus generally more expensive. As an electronic pressure switch has no moving parts (relative to each other), it usually has a much prolonged service life and provides a higher level of precision (depending on application). The hysteresis can be set over a wide range...

 Open the catalog to page 6
E.1 "Performance", adjustable at factory-7

Adjustment range of switching point The pressure range within which the switching point of an electronic pressure switch can be set is called adjustment range. The switching point corresponds to the pressure value at which the electric circuit of the output is opened or closed. Window function In the window function, the switch signal is programmed such that it remains ON or OFF between two values. This means a defined pressure range can be monitored. This function is only possible on the 053X series. pressure profile Hysteresis Rising/falling switching point The difference between the rising (upper)...

 Open the catalog to page 7
E.1 "Performance", adjustable at factory-8

Technical explanations for electronic pressure switches PNP output / high-side / plus-switching PNP output (plus-switching) is the most popular variant in Europe. Here the load is connected to the output of the switch and ground (GND as reference potential). NPN output / low-side / minus-switching For an NPN output (minus-switching), the load is connected to the switching output and to the positive line of the supply voltage (Uv+ as reference potential). Temperature errors and ranges The temperature (both of the medium and environment) generally has a signicant influence on the accuracy of an...

 Open the catalog to page 8
E.1 "Performance", adjustable at factory-9

Sampling rate The sampling rate (or sampling frequency) defines the number of samples per time unit (typically in seconds or milliseconds) taken from an analogue signal and converted to a digital signal. The sampling rate is an indicator of how fast the output signal of an electronic pressure switch responds to the pressure change at the input. CE mark Electronic pressure switches from SUCO fall under the 2014/30/EU EMC Directive. EC declarations of conformity have been issued for the electronic pressure switches are available on request or can be downloaded from our website. The relevant devices...

 Open the catalog to page 9
E.1 "Performance", adjustable at factory-10

Technical explanations for electronic pressure switches Conversion chart for pressure units Insulation strength According to the latest specifications for immunity to surges and lightning protection, the following must be taken into account when testing insulation strength: With insulation test devices having an inner resistance exceeding 42 Ohm, the insulation strength of electronic pressure switches can be tested up to 500 VDC. All contacts must be tested short-circuited against the housing. For a specific threshold value of test voltage, the protective circuit for surge protection is activated...

 Open the catalog to page 10
E.1 "Performance", adjustable at factory-11

General technical explanations User information Our pressure monitoring products may only be installed and started up by authorised specialists. The safety regulations of country-specific authorities must be observed, especially when working with mains voltages and oxygen, and in potentially explosive areas. Product information The technical information in this catalogue is based upon fundamental testing during product development and empirical values. The information cannot be used for all application scenarios. Testing of the suitability of our products for a specific application (such as the checking...

 Open the catalog to page 11
E.1 "Performance", adjustable at factory-12

RoHSII compliant Values 30% lower than in the table above must be used for brass housings. Gaseous applications In particular using additional sealant to attain the required leak tightness may be necessary for gas applications. Vacuum The values given in the technical details for the vacuum range are specified in millibars (mbar) below atmospheric pressure. Pressure change rate (~rise / ~fall) The pressure change rate denotes the pressure over time for the rising/falling pressure. The pressure change rate is specified in bar/s or bar/ms. The maximum pressure change rate for SUCO mechanical pressure...

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.