Catalog excerpts

Mechanical Pressure Switches sehctiwS erusserP lacinahceM
Open the catalog to page 1
Pressure switches PLUS with integrated connector and supplementary functions Hex 24, NC or NO, voltage up to 42 V Intelligent, supplementary electronic functions broaden the capabilities of mechanical pressure switches by adding numerous features: NAMUR diagnostic function (fail-safe) with short-circuit and cable break detection Overvoltage protection for prolonging the contact service life Active reduction of EMC emissions Temperature-controlled switching function (e.g. cold start, i.e. inactive switching function until a certain temperature is reached) In-rush current limitation (overload...
Open the catalog to page 2
Pressure switches PLUS with integrated connector and supplementary functions Overview of possible supplementary functions Code for order number Resistor Resistor circuit to NAMUR, refer to page 68 • Diagnostic function (fail-safe) with short-circuit and cable break detection Safety systems such as brake systems, hydrostatic steering systems and fire extinguisher systems Varistor Circuit with varistor for overvoltage limitation, refer to page 69 • Overvoltage protection for the prolonging of contact service life under conditions of inductive load and long connection length The flyback...
Open the catalog to page 3
Pressure switches PLUS Resistor circuit to NAMUR (pressure switches with part numbers 04XX-R) The additional circuitry of the switching contact of the pressure switch enables not only the states to be shown enabled and disabled, it also enables interrogation for line breaks (standby current principle) and short-circuits in the electric circuit. The resistor circuitry is designed such that the NAMUR specifications can be satisfied. An operating voltage of 8.2 VDC must be provided for NAMUR-compliant operation. A resistance of 11 kQ is present in the circuit when the switch contact is open....
Open the catalog to page 4
Pressure switches PLUS M.6Circuit with varistor for overvoltage limitation hex 24(pressure switches with part numbers 04XX-V) PS PLUS The switching off inductive consumers such as valves, relays and motors by a mechanical pressure switch generates a high voltage peak. The cause for this is the energy stored in the magnetic field of inductance, which entails an induction voltage when the current is changed. The induction voltage (or flyback voltage) is defined as follows: where L = Inductance di/dt = Change of current over time This induction voltage can result in discharge effects...
Open the catalog to page 5
0410 / 0412 / 0414 / 0416 / 0418 / 0422 / 0424 Diaphragm pressure switches, up to 42 V with supplementary functions • Zinc-plated steel (CrVI-free) • Overpressure safety up to 300 bar11 Plug-in types for diaphragm pressure switches70 0410/0411 Deutsch DT04-2P IP67, IP6K9K Adjustment range (tolerance at room temperature) 04XX Diaphragm pressure switches Supplementary functions Refer to page 24 for the temperature range and application thresholds of sealing materials. Your order number: 04XX - XXX XX - X - 00X 0 Static value. Dynamic value is 30-50 % lower. Values pertain to the...
Open the catalog to page 6
Adjustment range (tolerance at room temperature) 04XX Diaphragm pressure switches Supplementary functions Refer to page 24 for the temperature range and application thresholds of sealing materials. 1 Static value. Dynamic value is 30-50 % lower. Values pertain to the hydraulic/pneumatic part of the pressure switch. RoHSII compliant
Open the catalog to page 7
0411 / 0413 / 0415 / 0417 / 0419 / 0423 / 0425 Piston pressure switches, up to 42 V with supplementary functions • Zinc-plated steel (CrVI-free) • Overpressure safety up to 600 bar11 Plug-in types for piston pressure switches Refer to page 73 for height 04XX Piston pressure switches Adjustment range (tolerance at room temperature) Supplementary functions Refer to page 24 for the temperature range and application thresholds of sealing materials. |_l l Your order number: 04XX - XXX XX - X - 00X 11 Static value. Dynamic value is 30-50 % lower. Values pertain to the hydraulic/pneumatic part...
Open the catalog to page 8
Pressure switches PLUS Plug-in types for diaphragm and piston pressure switches Technical details of plug-in types Model / type Connector Protection class Overall height Contact assignment Model / type Connector Protection class Overall height (light grey) (dark grey) Contact assignment
Open the catalog to page 9
Technical explanations for mechanical pressure switches Diaphragm pressure switch NO Piston pressure switch NC What is a mechanical pressure switch? Mechanical pressure switches from SUCO monitor the pressure of liquid or gaseous media, and close or open an electrical circuit on reaching a set threshold. Diaphragm pressure switches SUCO diaphragm pressure switches are used in pressure ranges from 0.1 bar to 100 bar, meaning overpressure safety of 35, 100, 300 and 600 bar, depending on the used diaphragm type. Piston pressure switches Pressure ranges from 10 bar to 400 bar can be monitored...
Open the catalog to page 10
Classification of electrical switch functions Contact form DIN EN60947-5-1 SPST single pole, single throw SPST single pole, single throw Changeover contacts CO, change over (snap action) SPDT single pole, double throw The switching point (for rising pressure) and hysteresis increase, whilst the switch-back point (for falling pressure) sinks. Also, the effect of the maximum (system) pressure on the switchback point (for falling pressure ramp) must be factored in for tolerance-critical applications. The higher the (system) pressure, the lower the resulting switch-back value. Potential-free –...
Open the catalog to page 11
Technical explanations for mechanical pressure switches Hysteresis can be set at SUCO in range from approx. 10 % (at end of adjustment range) to 30 % or higher (at start of adjustment range), related to the respective switching point for hex 27 and 30 A/F pressure switches with adjustable hysteresis. The specifications in the catalogue only represent typical average values. Please ask about the possible setting ranges you may require. Our electronic pressure switches are excellently suited to extremely low or high hysteresis. The lowest possible hysteresis is set if nothing is specified in...
Open the catalog to page 12All SUCO Robert Scheuffele GmbH & Co. KG catalogs and technical brochures
-
T3 Robust pressure transmitters
11 Pages
-
T2 Robust pressure transmitters
11 Pages
-
Pressure Monitoring 2019
170 Pages
-
Transmission Technology
40 Pages
-
M.7 Hex 30, changeover
12 Pages
-
M.8 ATEX
12 Pages
-
M.9 Vacuum
11 Pages
-
M.10 Accessories
13 Pages
-
E.7 Accessories
12 Pages
-
M.5 Hex 24/27, ready-wired
11 Pages
-
M.3 Hex 24
19 Pages
-
M.1 Hex 24, integrated
17 Pages
-
Product Overview 2018
6 Pages
-
T.3
13 Pages
-
E5
13 Pages
-
M.4
11 Pages
-
M2
16 Pages