Overview
The document provides comprehensive technical specifications and operational guidelines for pressure transmitters, particularly those designed for low pressures and vacuum applications. These transmitters are robust, with high overpressure protection and long life expectancy, suitable for hydrogen and oxygen applications, and made with stainless steel for excellent media compatibility.
Specifications
Pressure transmitters are available in types 0645, 0650, and 0660, with output signals of 0.5 - 4.5 V ratiometric, 0 - 10 V, and 4 - 20 mA. They operate within a supply voltage range of 5 VDC to 32 VDC and have a mechanical life expectancy of 10 million pulsations. Standard pressure ranges are from -1 to 100 bar, with overpressure protection up to 200 bar and burst pressure up to 250 bar. Accuracy is ±0.5% full scale at room temperature, with long-term stability of < ±0.2% FS per year.
Materials and Compatibility
The housing and measuring cell are made of stainless steel (1.4305 / AISI 303), with seal materials including NBR, EPDM, and FKM, allowing for a broad temperature range and compatibility with various media. The standard sensor oil used is fluorine oil, not suitable for food applications.
Technical Features
The document explains the working principle of pressure transmitters, including the use of a piezo-resistive sensor and the Wheatstone bridge circuit. It highlights the benefits of silicone-on-sapphire technology and oil-filled stainless steel measuring cells for enhanced accuracy and stability.
Electrical and Mechanical Details
Transmitters are equipped with built-in protection against reverse polarity, short-circuit, and overvoltage. They comply with EMC standards and have a maximum connection cable length of 30 meters. Details on electrical connectors, threads, and order matrices for different configurations are provided.
Performance and Reliability
The document outlines the accuracy, non-linearity, hysteresis, and long-term stability of the transmitters, emphasizing their reliability under specified conditions. It discusses temperature errors and the importance of operating within compensated temperature ranges to minimize inaccuracies.
Specifications and Technical Details
The response time of pressure transmitters is influenced by A/D and D/A conversions and filtering to suppress unwanted signals. A typical 12-bit resolution allows for pressure changes of 0.024 bar to be recorded.
Sampling Rate
The sampling rate defines how quickly a pressure transmitter can respond to pressure changes, measured in samples per second or millisecond.
Standards and Compliance
The document lists various EMC standards that SUCO pressure transmitters comply with, including EN 55016 and EN 61000 series for radio disturbance and immunity tests. CE mark compliance under the 2014/30/EU EMC Directive is also mentioned.
Material Compatibility
Different materials used in pressure transmitters, such as titanium and various stainless steels, are discussed for their media compatibility. Titanium is noted for its resistance to corrosive media but is not recommended for oxygen or hydrogen applications.
Pressure Peak Dampening
Pressure transmitters can be equipped with a pressure snubber to protect against transient pressure loads, with a recommended bore diameter of 0.8 mm for liquid media.
Installation and Safety
Installation should be performed by authorized specialists, adhering to safety regulations. The document emphasizes the importance of testing product suitability for specific applications.
IP Protection Classes
IP protection classes are explained, detailing the protection levels against dust and water. IP67 and IP6K9K are recommended for outdoor and mobile hydraulic applications.
Thread Specifications
Cylindrical and conical threads are described, including recommended tightening torques for various thread types.
Pressure Change Rate and Overpressure Protection
The document specifies maximum pressure change rates for mechanical and electronic pressure switches and provides guidelines for overpressure protection.
RoHS and CE Compliance
SUCO products comply with RoHS and CE directives, with specific directives applicable to different product types. The document notes that mechanical pressure switches do not fall under the EMC Directive.
Conclusion
The document concludes with a note on the availability of CE declarations and the subject to technical changes disclaimer.
See more

Catalog excerpts

T.2 Pressure Transmitter, hex 22, stainless steel „303“-2

T.2 Robust pressure transmitters hex 22 Stainless steel housing (1.4305 / AISI 303, hex 22) stainless steel 1.4305 / AISI 303 • Pressure transmitters especially for low pressures, including vacuum applications • High overpressure protection (up to 3 x) • Long life time even under high pressure change rates • Housing and wetted parts are made of stainless steel providing excellent media compatibility • Suitable for hydrogen and oxygen applications • The highly-sensitive piezo-resistive sensor in the measuring cell filled with oil guarantees high level of accuracy, repeatability and long-term...

 Open the catalog to page 2
T.2 Pressure Transmitter, hex 22, stainless steel „303“-3

11 Static pressure, dynamic value is 30 to 50% lower. Values refer to the hydraulic/pneumatic part of the pressure transmitter. 2) Within the compensated temperature range.

 Open the catalog to page 3
T.2 Pressure Transmitter, hex 22, stainless steel „303“-4

T.2 hex 22 stainless steel 0645 / 0650 / 0660Electrical connectors and threads 1.4305 / AISI 303 DIN EN 175301-803-A Cable connection x ~ 44 mm (+ 20 mm bend relief) Cable length ~ 2 m d ~ 0 22 mm Sealing ring G1/4 DIN EN ISO 1179-2 (DIN 3852-11) form E RoHSII compliant

 Open the catalog to page 4
T.2 Pressure Transmitter, hex 22, stainless steel „303“-5

Order matrix for pressure transmitters Your order number: 06XX XXX 41 X XXX 1) Static pressure, dynamic pressure 30 to 50% lower. Values refer to the hydraulic or pneumatic part of the pressure transmitter.

 Open the catalog to page 5
T.2 Pressure Transmitter, hex 22, stainless steel „303“-6

Technical explanations for pressure transmitters What is a pressure transmitter? A pressure transmitter (also called pressure transducer or pressure converter) is a component used to convert a pneumatic or hydraulic pressure to an electric (usually analogue and linear) output signal, such as a current or voltage. electrical connection How does a pressure transmitter work? The pressure measuring cell fitted has a membrane (1) that is exposed to the pressure to be measured. Affixed on this membrane is a bridge circuit consisting of four ohmic resistors in the form of a Wheatstone bridge. The values...

 Open the catalog to page 6
T.2 Pressure Transmitter, hex 22, stainless steel „303“-7

Voltage output 0 - 10 V Transmitters with an output signal of 0 to 10 V are a commonly used variant due to their simple initial operation and straightforward scaling of the signal (0 V for 0 bar). The output load must be selected as highly resistive (with typical minimum value 4.7 kΩ). SUCO transmitters with voltage output have a 3-wire design. Conversion formula for pressure and voltage: Conversion formula for pressure and voltage: Uout = pressure applied x 10 V pressure range Voltage output 0.5 – 4.5 V ratiometric SUCO transmitters with ratiometric output are operated with a 5 V supply voltage...

 Open the catalog to page 7
T.2 Pressure Transmitter, hex 22, stainless steel „303“-8

Technical explanations for pressure transmitters Accuracy (to DIN EN 61298) The (measuring) accuracy of pressure transmitters is specified by SUCO as ±0.5% or ±1% of the span (also called full scale). Accuracy includes zero point offset, nonlinearity, hysteresis and non-repeatability, and is defined at room temperature and new state. This method defines the maximum deviation from the ideal line (in contrast to the BFSL method in which the average deviation is given). Other factors influencing the total accuracy, such as temperature and ageing, are specified separately. Hysteresis (to DIN EN 61298)...

 Open the catalog to page 8
T.2 Pressure Transmitter, hex 22, stainless steel „303“-9

digital word analogue signal analogue signal Resolution The A/D resolution (analogue - digital) of an pressure transmitter defines the smallest change of the analogue - digital - analogue conversion which takes places by the signal processing of an pressure transmitter. If for example 13-bit resolution is used for an pressure transmitter with a 100 bar setting range, the smallest signal change is 8192 steps (213). As state of the art a resolution of 12 bits and hence 4096 steps (212) is typical. Therefore pressure changes of 100 bar / 4096 = 0.024 bar can be recorded. Response time The response...

 Open the catalog to page 9
T.2 Pressure Transmitter, hex 22, stainless steel „303“-10

Technical explanations for pressure transmitters Conversion chart for pressure units Oxygen and hydrogen Country-specific safety requirements and application guidelines must be observed if the medium to be monitored is oxygen or hydrogen, such as DGUV accident prevention regulations (DGUV 500, Section 2.32 and BGI 617). Pressure peak dampening If required, our pressure transmitters can also be fitted with a pressure snubber (pressure peak orifice) to protect the measuring cell against transient pressure loads such as pressure peaks due to the switching of valves, cavitation effects, etc. which...

 Open the catalog to page 10
T.2 Pressure Transmitter, hex 22, stainless steel „303“-11

General technical explanations User information Our pressure monitoring products may only be installed and started up by authorised specialists. The safety regulations of country-specific authorities must be observed, especially when working with mains voltages and oxygen, and in potentially explosive areas. Product information The technical information in this catalogue is based upon fundamental testing during product development and empirical values. The information cannot be used for all application scenarios. Testing of the suitability of our products for a specific application (such as the checking...

 Open the catalog to page 11
T.2 Pressure Transmitter, hex 22, stainless steel „303“-12

RoHSII compliant Values 30% lower than in the table above must be used for brass housings. Gaseous applications In particular using additional sealant to attain the required leak tightness may be necessary for gas applications. Vacuum The values given in the technical details for the vacuum range are specified in millibars (mbar) below atmospheric pressure. Pressure change rate (~rise / ~fall) The pressure change rate denotes the pressure over time for the rising/falling pressure. The pressure change rate is specified in bar/s or bar/ms. The maximum pressure change rate for SUCO mechanical pressure...