video corpo

Steam Steriliser / Autoclave Catalogue
22Pages

{{requestButtons}}

Catalog excerpts

Steam Steriliser / Autoclave Catalogue - 1

STERILIZATION DEVICES I. Central Sterilization Units • Adela -OT Series II. Prismatic Steam Sterilizer III. Laboratory Type Vertical And Horizontal Steam Sterilizer • SM Series IV. Prismatic Steam Sterilizer V. Washer and Steam Sterilizer VI. Laboratory Type Vertical Steam Sterilizer sumer - - -■l vwvw.s u men nc.com ^HYGCEIST

Open the catalog to page 1
Steam Steriliser / Autoclave Catalogue - 2

About us Sumer A.§. was established in 1981 in Ankara to proved services in the medical device sector. It has aimed advancement since the day of its establishment by also taking growth and compliance with the contemporary technologies and protecting the environmental conditions. Our manufacturing takes place in an area of 25.000 m2 in Ankara Organized Industrial Zone. Our Firm is following the innovations in its sector and in abroad through its research and development unit and its application staff with a strong infrastructure of engineers, and is continuing to produce devices it had...

Open the catalog to page 2
Steam Steriliser / Autoclave Catalogue - 3

To make the Sumer brand a global brand to make our Firm remembered first in the sector. Our Mission Our main task is to create designs with competition power in the global sense by taking the priorities of the sector into consideration and being respectful to the environment and people and giving the first priority to the wishes and expectations of customers, and also to produce innovative technological medical products by meeting all the national and international legal requirements. Our Basic Values ™ We are bound up with the Medical Ethical Rules, ™ We are people-oriented, ™ We respect...

Open the catalog to page 3
Steam Steriliser / Autoclave Catalogue - 4

I. Central Sterilization Units Our Firm implements turn-key sterilization projects designed by taking the hospital sizes into consideration, and gives services for the installation and commissioning of turn-key Central Sterilization Units. “It is essential for Central Sterilization Units (CSU) to eliminate the microorganisms existing in hospitals." Sumer A.§. offers the following turn-key services for you, our valuable customers, in relation with the Central Stelization Units; — Design, ™ Central construction, — Installation ofproducts, ™ Commissioning, ■■ Control and similar. Sterilization...

Open the catalog to page 4
Steam Steriliser / Autoclave Catalogue - 5

Sterilization Process DECONTAMINATION STERILIZATION DISINFECTION VALIDATION Sterilization must not be taken as a simple procedure; it must be considered as providing new materials suitable for medical purposes, or a process of novel production. STERILIZATION DEVICES

Open the catalog to page 5
Steam Steriliser / Autoclave Catalogue - 6

ADELA-OT series ADELA-OT series steam sterilizers are designed and manufactured regarding the manufacturing and product standards. General Characteristics Control System Operation Mod Screen Type Screen Size Keypad Printer Remote Control and Communication Warning Sytem Data Storage Monitoring Mobility Steam Generator PLC CPU Fully Automatic / Button Command Multi-Color TFT, LCD Touch Screen 7,0" (10,0" optional) Touch Screen 40 Character/Line, Thermal Printer RS 232 Port / USB, Ethernet (optional) Visual & Audio & Printed Up to 200 Cycles Touch Screen, Anaolgue Gauges for Chamber, Jacket,...

Open the catalog to page 6
Steam Steriliser / Autoclave Catalogue - 7

Protects operator from electrical current leaks. Short circuit protection. Safety valve. Hepa filter for air filtration. Water level control via buoy in generator. Pneumatic Valves for precise exhausting. Leak test. Pre-vacuum cycle Password protection. Sensors against obstructions on the doors pathway. Doors locks under pressure. Emergency stop button. Unable to open both doors at once double door models. Relevant Directives and Standards Medical Device Directive Medical Device Class Low Voltage Directive EMC Directive Pressure Equipments Directive Steam Sterilizer Directive Quality...

Open the catalog to page 7
Steam Steriliser / Autoclave Catalogue - 8

Technical Data Sheet Chamber volUme (lIter) and dImenSIonS devICe dImenSIon PaCKInG dImenSIon devICe WeIGht

Open the catalog to page 8
Steam Steriliser / Autoclave Catalogue - 9

GENERATOR DIMENSION STERILIZATION DEVICES

Open the catalog to page 9
Steam Steriliser / Autoclave Catalogue - 10

Technical Data Sheet INSTALLATION CONDITIONS: At least 60 cm. space is needed on both lateral sides of the device to provide an effective technical service. Exhaust fan or ventilation funnel needs to be placed above the device for an effective evacuation of heat. *AII specifications herein are provided for information purposes only and may be modified without notice.

Open the catalog to page 10
Steam Steriliser / Autoclave Catalogue - 11

Technical Data Sheet JACKET

Open the catalog to page 11
Steam Steriliser / Autoclave Catalogue - 12

Adela range provides a single solution for the multiples sterilization needs on laboratories including instruments, hollowware elements, glassware and other laboratory items that need a final drying to avoid contamination. Load has to be placed into the vessel's baskets and after automatic filling with distilled water, device starts to heat up and purge until set temperature is reached. In case of solid objects, discharge is automatically Operating Principal Vertical and table-top range provides a single solution for the multiples sterilization needs on laboratories including instruments,...

Open the catalog to page 12
Steam Steriliser / Autoclave Catalogue - 13

Pre-vacuum and Filling Stage Heating Stage Sterilization Control Cooling and Drying Stage Security 2014/35/EU 2014/30/EU 2014/68/EU Integrated vacuum pump for initial pre-vacuum and subsequent automatic water filling. Fast saturated steam production by means of powerful heating elements. A PT-100 temperature probe controls the chamber temperature, with the possibility of installing another flexible PT-100 temperature probe for liquid programs. In solid program, discharge is automatically forced during cooling stage to reduce the cycle time. Then, integrated heating jacket together with...

Open the catalog to page 13
Steam Steriliser / Autoclave Catalogue - 14

STERILIZATION DEVICES

Open the catalog to page 14
Steam Steriliser / Autoclave Catalogue - 15

IV. Prismatic Steam Sterilizer This is produced for the sterilization of surgical and wound dressing tools, plastic and glass materials and bottled fluids by trained, certificated and officially assigned hospital staff. General Characteristics Control System Way of use Screen Type Screen Dimensions Keypad Printer Communication Warning system Data Storage Procedure follow-up/tracing Motility Vaporcontrol PLC processor Full automatic / buttons and touch screen Color TFT, Touch LCD 7,0" (10,0" Optional) Touch Screen 40 Characters / lines, integrated thermal printer RS232 /485 Port - USB...