BioFX™ 450 nm Liquid Stop Reagent for TMB Microwell Substrates (LSTP)
9Pages

{{requestButtons}}

Catalog excerpts

BioFX™ 450 nm Liquid Stop Reagent for TMB Microwell Substrates (LSTP) - 1

This safety data sheet was created pursuant to the requirements of: 2012 OSHA Hazard Communication Standard (29 CFR 1910.1200) BioFX™ 450 nm Liquid Stop Reagent for TMB Microwell Substrates (LSTP) 1. Identification_ Product identifier Product Name BioFX™ 450 nm Liquid Stop Reagent for TMB Microwell Substrates Other means of identification Product Code(s) LSTP Synonyms None Recommended use of the chemical and restrictions on use Recommended use For laboratory use Restrictions on use No information available Details of the supplier of the safety data sheet Supplier Address Surmodics, Inc. 9924 West 74th Street Eden Prairie, MN 55344 USA Telephone: 952-500-7000 Emergency telephone number Emergency Telephone Chemtrec 1-800-424-9300 Hazards not otherwise classified (HNOC) Not applicable Label elements Danger Hazard statements Causes skin irritation Causes serious eye damage May cause an allergic skin reaction

Open the catalog to page 1
BioFX™ 450 nm Liquid Stop Reagent for TMB Microwell Substrates (LSTP) - 2

Precautionary Statements - Prevention Wash face, hands and any exposed skin thoroughly after handling Avoid breathing dust/fume/gas/mist/vapors/spray Contaminated work clothing must not be allowed out of the workplace Wear protective gloves/eye protection/face protection Precautionary Statements - Response Specific treatment (see .? on this label) IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing Immediately call a POISON CENTER or doctor IF ON SKIN: Wash with plenty of water and soap Take off contaminated...

Open the catalog to page 2
BioFX™ 450 nm Liquid Stop Reagent for TMB Microwell Substrates (LSTP) - 3

BioFX™ 450 nm Liquid Stop Reagent for TMB Microwell Substrates (LSTP) allergic skin reaction. In the case of skin irritation or allergic reactions see a physician. Ingestion Rinse mouth. Never give anything by mouth to an unconscious person. Do NOT induce vomiting. Call a physician. Self-protection of the first aider Avoid contact with skin, eyes or clothing. Wear personal protective clothing (see section 8). Most important symptoms and effects, both acute and delayed Symptoms Burning sensation. Itching. Rashes. Hives. Indication of any immediate medical attention and special treatment...

Open the catalog to page 3
BioFX™ 450 nm Liquid Stop Reagent for TMB Microwell Substrates (LSTP) - 4

Advice on safe handling Handle in accordance with good industrial hygiene and safety practice. Avoid contact with skin, eyes or clothing. Do not eat, drink or smoke when using this product. Ensure adequate ventilation. In case of insufficient ventilation, wear suitable respiratory equipment. Take off contaminated clothing and wash before reuse. Conditions for safe storage, including any incompatibilities Storage Conditions Keep containers tightly closed in a dry, cool and well-ventilated place. Store locked up. Keep out of the reach of children. Control parameters Exposure Limits This...

Open the catalog to page 4
BioFX™ 450 nm Liquid Stop Reagent for TMB Microwell Substrates (LSTP) - 5

BioFX™ 450 nm Liquid Stop Reagent for TMB Microwell Substrates (LSTP) Flammability Flammability Limit in Air Upper flammability or explosive limits Lower flammability or explosive limits Vapor pressure Relative vapor density Relative density Water solubility Solubility(ies) Partition coefficient Autoignition temperature Decomposition temperature Kinematic viscosity Dynamic viscosity No data available No data available No data available No data available No data available No data available Completely soluble No data available No data available No data available No data available No data...

Open the catalog to page 5
BioFX™ 450 nm Liquid Stop Reagent for TMB Microwell Substrates (LSTP) - 6

BioFX™ 450 nm Liquid Stop Reagent for TMB Microwell Substrates (LSTP) Symptoms related to the physical, chemical and toxicological characteristics

Open the catalog to page 6
BioFX™ 450 nm Liquid Stop Reagent for TMB Microwell Substrates (LSTP) - 7

BioFX™ 450 nm Liquid Stop Reagent for TMB Microwell Substrates (LSTP) Other adverse effects No information available. 13. Disposal considerations Disposal methods Waste from residues/unused products Contaminated packaging Dispose of in accordance with local regulations. Dispose of waste in accordance with environmental legislation. Do not reuse empty containers. 14. Transport information DOT UN number or ID number Proper shipping name Transport hazard class(es) Packing group Special Provisions DOT Marine Pollutant Description Emergency Response Guide Number UN3265 Corrosive liquid, acidic,...

Open the catalog to page 7
BioFX™ 450 nm Liquid Stop Reagent for TMB Microwell Substrates (LSTP) - 8

BioFX™ 450 nm Liquid Stop Reagent for TMB Microwell Substrates (LSTP) Special Provisions Marine pollutant Description 274 P UN3265, Corrosive liquid, acidic, organic, n.o.s., 8, II, Marine pollutant 15. Regulatory information International Inventories US Federal Regulations SARA 313 Section 313 of Title III of the Superfund Amendments and Reauthorization Act of 1986 (SARA). This product does not contain any chemicals which are subject to the reporting requirements of the Act and Title 40 of the Code of Federal Regulations, Part 372. SARA 311/312 Hazard Categories Should this product meet...

Open the catalog to page 8
BioFX™ 450 nm Liquid Stop Reagent for TMB Microwell Substrates (LSTP) - 9

BioFX™ 450 nm Liquid Stop Reagent for TMB Microwell Substrates (LSTP) U.S. Environmental Protection Agency High Production Volume Chemicals Food Research Journal Hazardous Substance Database International Uniform Chemical Information Database (IUCLID) National Institute of Technology and Evaluation (NITE) Australia National Industrial Chemicals Notification and Assessment Scheme (NICNAS) NIOSH (National Institute for Occupational Safety and Health) National Library of Medicine's ChemID Plus (NLM CIP) National Library of Medicine’s PubMed database (NLM PUBMED) National Toxicology Program...

Open the catalog to page 9