1. Catalogs
  2. Surmodics IVD, Inc.
  3. StabilCoat™ Plus Microarray Stabilizer (SC02)

StabilCoat™ Plus Microarray Stabilizer (SC02)

StabilCoat™ Plus Microarray Stabilizer (SC02)

StabilCoat™ Plus Microarray Stabilizer (SC02)

Product catalog summary
Identification
Product Name: StabilCoat™ Plus Microarray Stabilizer (SC02). Recommended for laboratory use. Supplier: Surmodics, Inc., Eden Prairie, MN, USA. Emergency contact: Chemtrec 1-800-424-9300.
Hazard Identification
Classified as a skin sensitizer (Category 1). May cause allergic skin reactions. Precautionary measures include avoiding inhalation and wearing protective gloves.
Composition
Contains 3(2H)-Isothiazolone, 2-methyl- (CAS No 2682-20-4) at less than 0.1%.
First-aid Measures
In case of skin contact, wash with soap and water. If irritation occurs, seek medical attention. For eye contact, rinse thoroughly with water.
Fire-fighting Measures
Use appropriate extinguishing media. Firefighters should wear protective gear. Product may cause sensitization by skin contact.
Accidental Release Measures
Avoid contact with skin and eyes. Use personal protective equipment. Contain and clean up spills safely.
Handling and Storage
Handle with good industrial hygiene. Store in a cool, dry, well-ventilated area.
Exposure Controls/Personal Protection
Use ventilation systems. Wear safety glasses and gloves. No specific respiratory protection needed under normal conditions.
Physical and Chemical Properties
Liquid state, clear golden color, completely soluble in water. No data available for many properties such as boiling point and flash point.
Stability and Reactivity
Stable under normal conditions. No hazardous reactions expected.
Toxicological Information
May cause skin sensitization. Harmful if inhaled or ingested in large quantities.
Ecological Information
Harmful to aquatic life. No data on persistence or bioaccumulation.
Disposal Considerations
Dispose of in accordance with local regulations. Do not reuse containers.
Transport Information
Not regulated under DOT, IATA, or IMDG.
Regulatory Information
Complies with TSCA. Not subject to SARA 313 or California Proposition 65.
Other Information
NFPA ratings: Health 2, Flammability 1, Instability 0. HMIS ratings: Health 1*, Flammability 1, Physical hazards 0.
See more

Catalog excerpts

StabilCoat™ Plus Microarray Stabilizer (SC02)-1

SAFETY DATA SHEET This safety data sheet was created pursuant to the requirements of: 2012 OSHA Hazard Communication Standard (29 CfR 1910.1200) StabilCoat™ Plus Microarray Stabilizer (SC02) Product identifier Product Name StabilCoat™ Plus Microarray Stabilizer Other means of identification Product Code(s) SC02 Synonyms None Recommended use of the chemical and restrictions on use Recommended use For laboratory use Restrictions on use No information available Details of the supplier of the safety data sheet Supplier Address Surmodics, Inc. 9924 West 74th Street Eden Prairie, MN 55344 USA Telephone: 952-500-7000 Emergency telephone number Emergency Telephone Chemtrec 1-800-424-9300 Skin sensitization Hazards not otherwise classified (HNOC) Not applicable Label elements Warning Hazard statements May cause an allergic skin reaction

 Open the catalog to page 1
StabilCoat™ Plus Microarray Stabilizer (SC02)-2

Precautionary Statements - Prevention Avoid breathing dust/fume/gas/mist/vapors/spray Contaminated work clothing must not be allowed out of the workplace Wear protective gloves Precautionary Statements - Response Specific treatment (see .? on this label) IF ON SKIN: Wash with plenty of water and soap If skin irritation or rash occurs: Get medical advice/attention Wash contaminated clothing before reuse Precautionary Statements - Disposal Dispose of contents/container to an approved waste disposal plant Other information Causes mild skin irritation. Harmful to aquatic life. Description of first...

 Open the catalog to page 2
StabilCoat™ Plus Microarray Stabilizer (SC02)-3

StabilCoat™ Plus Microarray Stabilizer (SC02) Symptoms Itching. Rashes. Hives. Prolonged contact may cause redness and irritation. Indication of any immediate medical attention and special treatment needed Note to physicians May cause sensitization in susceptible persons. Treat symptomatically. 5. Fire-fighting measures Suitable Extinguishing Media Large Fire Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. CAUTION: Use of water spray when fighting fire may be inefficient. Unsuitable extinguishing media Do not scatter spilled material with...

 Open the catalog to page 3
StabilCoat™ Plus Microarray Stabilizer (SC02)-4

Control parameters Exposure Limits The following ingredients are the only ingredients of the product above the cut-off level (or level that contributes to the hazard classification of the mixture) which have an exposure limit applicable in the region for which this safety data sheet is intended or other recommended limit. At this time, the other relevant constituents have no known exposure limits from the sources listed here. Eyewash stations Ventilation systems. Individual protection measures, such as personal protective equipment Eye/face protection Wear safety glasses with side shields (or...

 Open the catalog to page 4
StabilCoat™ Plus Microarray Stabilizer (SC02)-5

Relative density Water solubility Solubility(ies) Partition coefficient Autoignition temperature Decomposition temperature Kinematic viscosity Dynamic viscosity Other information Explosive properties Oxidizing properties Softening point Molecular weight VOC Content (%) Liquid Density Bulk density No data available Completely soluble No data available No data available No data available No data available No data available No information available No information available No information available No information available No information available No information available No information available...

 Open the catalog to page 5
StabilCoat™ Plus Microarray Stabilizer (SC02)-6

Component Information

 Open the catalog to page 6
StabilCoat™ Plus Microarray Stabilizer (SC02)-7

Other adverse effects No information available. Disposal methods Waste from residues/unused Dispose of in accordance with local regulations. Dispose of waste in accordance with products environmental legislation. Contaminated packaging Do not reuse empty containers. US Federal Regulations SARA 313 Section 313 of Title III of the Superfund Amendments and Reauthorization Act of 1986 (SARA). This product does not contain any chemicals which are subject to the reporting requirements of the Act and Title 40 of the Code of Federal Regulations, Part 372. SARA 311/312 Hazard Categories Should this product...

 Open the catalog to page 7
StabilCoat™ Plus Microarray Stabilizer (SC02)-8

StabilCoat™ Plus Microarray Stabilizer (SC02) This product does not contain any Proposition 65 chemicals. European Union Hazard classification is based on ECHA CLP harmonized classification of Methylisothiazolinone 2-methyl-2H-isothiazol-3-one (Cas: 2682-20-4). HMIS Health hazards 1* Flammability 1 Physical hazards 0 Personal protection X Chronic Hazard Star Legend * = Chronic Health Hazard Key or legend to abbreviations and acronyms used in the safety data sheet Legend Section 8: Exposure controls/personal protection TWA TWA (time-weighted average) STEL STEL (Short Term Exposure Limit) Ceiling...

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.