Monitor AMI Rescon
1 / 2Pages

Catalog excerpts

Monitor AMI Rescon - 1

SWAN Analytische Instrumente AG CH-8340 Hinwil/Switzerland Tel. +41 44 943 63 00 swan@swan.ch . www.swan.ch Monitor AMI Rescon Data sheet No. DenA23431X00 Complete monitoring system for the automatic, continuous measurement of the specific resistivity / specific conductivity in high purity water. Monitor AMI Rescon Complete system mounted on stainless steel mounting panel:  Transmitter AMI Rescon in a rugged aluminum enclosure (IP 66).  Swansensor RC-U high precision two-wire electrode made of stainless steel with integrated NTC temperature probe for automatic temperature compensation.  Flow cell QV-Hflow made of stainless steel with manual flow adjustment valve and digital, high temperature sample flow meter.  Factory tested, ready for installation and operation. Specifications:  Measurement range: - Resistivity: 0.01 to 18.18 MΩ-cm - Conductivity: 0.055 to 1000 S/cm  Big backlit LC display for the reading of measuring value, sample temperature, sample flow, temperature compensation type and operating status.  Easy user menus in English, German, French and Spanish. Simple programming of all parameters by keypad.  Wide range of selectable temperature compensations for different sample conditions.  Alarm function according to the limits in USP<645>.  Electronic record of major process events and calibration data.  Data logger for 1’500 data records stored at a selectable interval.  Two current outputs (0/4 - 20 mA) for measured signals. Accessory:  Precision test resistor plug for verification of transmitter according to USP<645>. Monitor AMI Rescon DC Option: [ ] 3rd current signal output (0/4 – 20mA) [ ] Profibus DP & Modbus RTU interface (RS-485) [ ] HART interface 06/2020 Subject to change without notice

Open the catalog to page 1
Monitor AMI Rescon - 2

SWAN Analytische Instrumente AG CH-8340 Hinwil/Switzerland Tel. +41 44 943 63 00 swan@swan.ch . www.swan.ch Conductivity Measurement Monitor AMI Rescon Data sheet No. DenA23431X00 Electrical Connection Scheme Swansensor RC-U (k = 0.01 cm ) with integrated NT5K temperature sensor. Measuring range Resolution 0.01 to 18.18 MΩ-cm 0.01 MΩ-cm 0.055 to 2.999 S/cm 0.001 S/cm 3.00 to 29.99 S/cm 0.01 S/cm 30.0 to 99.9 S/cm 0.1 S/cm 100 to 1000 S/cm 1 S/cm Automatic range switching. System accuracy 0.01 to 18.18 MΩ-cm 0.05 to 20 S/cm 20 to 1000 S/cm Periodic accuracy test with ultra high...

Open the catalog to page 2

All Swan Analytical Instruments catalogs and technical brochures