Catalog excerpts

SWAN Analytische Instrumente AG CH-8340 Hinwil/Switzerland Tel. +41 44 943 63 00 swan@swan.ch . www.swan.ch Monitor AMI Turbitrace Data sheet no. DenA2541X500 Nephelometric system for the automatic and continuous measurement of low level turbidity in pure and ultra-pure water. High precision nephelometer complying with ISO 7027 (EN 27027, DIN 38404) Measurement range: 0.000 - 100.0 FNU/NTU Automatic range switching. Precision: ± 0.001 FNU/NTU or 1% of reading. Response time: typically T90 < 15 sec (after sample entry at 10 l/h) Programmable automatic zero point measurement for drift compensation by integrated submicron particle filter. Complete system including transmitter, turbidity sensor, flow cell with integrated sub-micron filter, flow controller and flow sensor. Installed on panel for immediate use. Pressure tight sample system up to 10 bar avoids outgassing of sample. Transmitter with large backlit graphic display for the reading of measuring value, flow and operating status. Full text menu driven user interface. Storage of calibration history. Two signal outputs for measuring values or as control outputs. Alarm contact as summary alarm indication for programmable alarm values and for instrument faults. Alarm functions include: “Flow out of range”, “Cleaning required“ and “Replace filter”. Two potential-free contacts programmable as limit switches or PID-controllers. Input for potential-free contact with programmable function. Valve and connector for slope calibration with formazine according to ISO 7027. Monitor AMI Turbitrace DC Option: [ ] 3 current signal output (0/4 – 20mA) [ ] Profibus DP & Modbus RTU interface (RS-485) [ ] HART interface
Open the catalog to page 1
SWAN Analytische Instrumente AG CH-8340 Hinwil/Switzerland Tel. +41 44 943 63 00 swan@swan.ch . www.swan.ch Turbidity Measurement Monitor AMI Turbitrace Data sheet no. DenA2541X500 Electrical Connection Scheme Turbidimeter with flow controller and programmable automatic zero point measurement for drift compensation by integrated sub-micron particle filter. Measurement range: 0.000 - 100.0 FNU/NTU with automatic range switching Precision: 0.001 FNU/NTU or 1% of reading Transmitter Specifications and Functionality Electronics case: Cast aluminum Protection degree: IP 66 / NEMA 4X Display:...
Open the catalog to page 2All Swan Analytical Instruments catalogs and technical brochures
-
Swansensor pH/Redox AY
1 Pages
-
Monitor AMI Turbitrack
2 Pages
-
AMI INSPECTOR
2 Pages
-
Swansensor PHARMACON
1 Pages
-
Monitor AMI LineTOC
2 Pages
-
Monitor AMI Turbiwell 7027
2 Pages
-
Monitor AMI Codes-II O3
2 Pages
-
Monitor AMI Oxytrace QED
2 Pages
-
Monitor AMI Rescon
2 Pages
-
Redox Calibration Solution
9 Pages