Monitor AMI Turbitrace

Monitor AMI Turbitrace

Monitor AMI Turbitrace

Product catalog summary
Overview: The Monitor AMI Turbitrace is a high-precision nephelometric system designed for the automatic and continuous measurement of low-level turbidity in pure and ultra-pure water. It complies with ISO 7027 standards and offers a measurement range of 0.000 - 100.0 FNU/NTU with automatic range switching.
Specifications:
  • Precision: ±0.001 FNU/NTU or ±1% of reading.
  • Response Time: Typically T90 < 15 seconds.
  • Pressure Tight Sample System: Up to 10 bar to prevent outgassing.
  • Transmitter: Features a large backlit graphic display and a full-text menu-driven user interface.
  • Power Supply: Available in AC (100-240 VAC) and DC (10-36 VDC) versions.
System Components: The system includes a transmitter, turbidity sensor, flow cell with an integrated sub-micron filter, flow controller, and flow sensor, all installed on a panel for immediate use.
Functional Features:
  • Automatic Zero Point Measurement: For drift compensation using an integrated sub-micron particle filter.
  • Calibration: Includes a valve and connector for slope calibration with formazine according to ISO 7027.
  • Alarm Functions: Programmable alarms for flow out of range, cleaning required, and filter replacement.
  • Data Storage: Stores calibration history, event log, alarm log, and up to 1,500 data records.
Safety and Control:
  • Data Protection: No data loss after power failure, with all data saved in non-volatile memory.
  • Over-voltage Protection: For inputs and outputs.
  • Control Functions: Programmable relays or current outputs for dosing pumps, solenoid valves, or motor valves with P, PI, PID, or PD control parameters.
Communication Interfaces (Optional): RS485 interface with Modbus RTU or Profibus DP, USB interface, and HART interface.
Sample Conditions:
  • Temperature: 1 - 40°C
  • Flow: 5 - 20 l/h
  • Pressure: 1 - 10 bar
Physical Specifications:
  • Panel Dimensions: 280 x 850 x 200 mm
  • Panel Material: PVC
  • Total Monitor Weight: 9.0 kg
See more

Catalog excerpts

Monitor AMI Turbitrace-1

SWAN Analytische Instrumente AG CH-8340 Hinwil/Switzerland Tel. +41 44 943 63 00 [email protected] . www.swan.ch Monitor AMI Turbitrace Data sheet no. DenA2541X500 Nephelometric system for the automatic and continuous measurement of low level turbidity in pure and ultra-pure water.  High precision nephelometer complying with ISO 7027 (EN 27027, DIN 38404)  Measurement range: 0.000 - 100.0 FNU/NTU Automatic range switching.  Precision: ± 0.001 FNU/NTU or 1% of reading.  Response time: typically T90 < 15 sec (after sample entry at 10 l/h)  Programmable automatic zero point measurement for drift compensation by integrated submicron particle filter.  Complete system including transmitter, turbidity sensor, flow cell with integrated sub-micron filter, flow controller and flow sensor. Installed on panel for immediate use.  Pressure tight sample system up to 10 bar avoids outgassing of sample.  Transmitter with large backlit graphic display for the reading of measuring value, flow and operating status. Full text menu driven user interface. Storage of calibration history.  Two signal outputs for measuring values or as control outputs.  Alarm contact as summary alarm indication for programmable alarm values and for instrument faults. Alarm functions include: “Flow out of range”, “Cleaning required“ and “Replace filter”.  Two potential-free contacts programmable as limit switches or PID-controllers.  Input for potential-free contact with programmable function.  Valve and connector for slope calibration with formazine according to ISO 7027. Monitor AMI Turbitrace DC Option: [ ] 3 current signal output (0/4 – 20mA) [ ] Profibus DP & Modbus RTU interface (RS-485) [ ] HART interface

 Open the catalog to page 1
Monitor AMI Turbitrace-2

SWAN Analytische Instrumente AG CH-8340 Hinwil/Switzerland Tel. +41 44 943 63 00 [email protected] . www.swan.ch Turbidity Measurement Monitor AMI Turbitrace Data sheet no. DenA2541X500 Electrical Connection Scheme Turbidimeter with flow controller and programmable automatic zero point measurement for drift compensation by integrated sub-micron particle filter. Measurement range: 0.000 - 100.0 FNU/NTU with automatic range switching Precision: 0.001 FNU/NTU or 1% of reading Transmitter Specifications and Functionality Electronics case: Cast aluminum Protection degree: IP 66 / NEMA 4X Display: backlit...